{"title":"ATSE Controller","description":"\u003cp\u003e\u003cspan\u003eATSE controllers monitor main and reserve power sources, control external transfer switches or contactor pairs and send a remote start\/stop signal to a generator controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDepending on model, these controllers have various configuration settings, delays, voltage and frequency max\/min limits. They could display measured parameters including voltage, frequency, current and power metered values. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSome models are able to control 3 power sources including mains, generators, inverters and other power sources in various combinations. \u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"smartgen-hat310-120vac-ats-controller-120-240vac-50-60hz-1-3-phase-version","title":"SMARTGEN HAT310 Dual Power ATS Controller 230\/400 VAC","description":"\u003cp\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003cbr\u003e\nDisplay    LED\u003cbr\u003e\nAC System    1P2W\/3P4W\u003cbr\u003e\nAlternator Frequency    50\/60Hz\u003cbr\u003e\nSwitch Over Priority    ●\u003cbr\u003e\nApplicable Switch Type    PC Two-stage and CC Switch\u003cbr\u003e\nCase Dimensions(mm)    110*77.5*55\u003cbr\u003e\nPanel Cutout(mm)    65*65.1\u003cbr\u003e\nOperating Temp.    (-25~+70)℃\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHAT310 ATS Controller is suitable for 2-stage of PC, and ATS of CC class (close signal is constant output). It can accurately detect 3-phase 4-wire mains voltage and generator single phase voltage. When mains under voltage and loss of phase occurred, HAT310 will control ATS transfer after delay. If mains are unavailable, the controller has the function to initiate signals to start gen-set.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eHAT310 controller can detect 3-phase 4-wire mains voltage\/generator single phase voltage and control ATS.\u003c\/p\u003e\n\n\u003cp\u003eMain characteristics are as follows,\u003c\/p\u003e\n\n\u003cp\u003e1. With aotomatic charge and automatic recorvery function.\u003cbr\u003e\n2. With under volatge and loss of phase detection function.\u003cbr\u003e\n3. LED indicators on the pannal can show working status of controller clearly.\u003cbr\u003e\n4. Applicable for 2 isolated neutral line.\u003cbr\u003e\n5. Mains normal delay configured via potentiometer (range: 1~60s), and generator normal delay via potentiometer (range: 1~60s)\u003cbr\u003e\n6. Mians is unavailable, if any phase voltage belows minimum working voltage or phase loss occurred gen-set will be started. \u003cbr\u003e\n7. Output contact capacity of mains and generator transfer relay is 16A AC250V, which can directly used to drive switch conversion. \u003cbr\u003e\n8. Output contact capacity of GENS START relay is 16A AC250V, it is volt free normally-open\/normally-closed contect. \u003cbr\u003e\n9. Strong anti-electromagnetic interference performance enable controller to use in the enviroment with strong electromagnetic interfrence.\u003cbr\u003e\n10. Modular design, self extinguishing ABS plastic shell, pluggable terminal, compact structure;\u003cbr\u003e\n11. Two installation ways: internal 35mm slideway and internal screw mounting.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n \u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":29024663863330,"sku":"HAT310-S01","price":109.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/5920e7f4-3366-589b-9297-652bf3944cbc.jpg?v=1562267600"},{"product_id":"smartgen-hat833-three-power-ats-controller","title":"SmartGen HAT833 Three Power ATS controller","description":"\u003cp\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003cbr\u003e\nDisplay  LCD(240*128)\u003cbr\u003e\nLanguage  Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input  8\u003cbr\u003e\nProgrammable Output  12\u003cbr\u003e\nAC System  1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency  50\/60Hz\u003cbr\u003e\nCurrent and Power Display  ●\u003cbr\u003e\nOver Current Warn  ●\u003cbr\u003e\nVolt Freq Protection  ●\u003cbr\u003e\nMonitor Interface  USB\/RS485-1\/RS485-2\u003cbr\u003e\nProgrammable Interface  USB\/RS485-1\/RS485-2\u003cbr\u003e\nRTC(Real Time Clock)  ●\u003cbr\u003e\nScheduled Start Genset  ●\u003cbr\u003e\nCirculate Start Genset  ●\u003cbr\u003e\nSwitch Over Priority  ●\u003cbr\u003e\nDC Supply  DC(8～35)V\u003cbr\u003e\nCase Dimensions(mm)  260*180*54\u003cbr\u003e\nPanel Cutout(mm)  242*161\u003cbr\u003e\nOperating Temp.  (-25~+70)℃\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHAT833 Three Power ATS controller is intelligent tri-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digitization, intelligence and networking. Automatic measurement and control can reduce incorrect operation, which is an ideal option for ATS.\u003c\/p\u003e\n\n\u003cp\u003eThe powerful Microprocessor contained within the unit allows for precision voltage (3-way 3-phase) measuring and make accurate judgment and the corresponding volt free digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase, phase sequence wrong and other abnormal condition occurs. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc. \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e1.    System type can set as: Mains-Mains-Gen, Mains-Mains-Mains, Mains-Gen-Mains, etc;\u003cbr\u003e\n2.    4.3 inchs solid color 240x128 LCD display with white backlight, multilingual interface (including English, Simplified Chinese or other languages), push-button operation; \u003cbr\u003e\n3.    Collect and display 3-way 3-phase voltage, frequency and phase sequence;\u003cbr\u003e\n4.    Collect and display load active power, reactive power, apparent power, power factor and current;\u003cbr\u003e\n5.    S1\/S2\/S3 separated over current warning\/ trip alarm;\u003cbr\u003e\n6.    NEL (Non-essential Load) trip function;\u003cbr\u003e\n7.    Display S1\/S2\/S3 total kW energy, total kvar energy, total close times;\u003cbr\u003e\n8.    Display continuous power supply time and S1\/S2\/S3 total power supply time;\u003cbr\u003e\n9.    For Stored-Energy type ATS, its close relay will active after the PF Input is active; \u003cbr\u003e\n10.    Over\/under voltage, over\/under frequency, over current, loss of phase, phase sequence wrong protection; \u003cbr\u003e\n11.    Automatic\/Manual mode. In manual mode, can force the switch to close or open;\u003cbr\u003e\n12.    All parameters can be set on site. Passwords authentication ensures authorized staff operation only; \u003cbr\u003e\n13.    The genset can be manual test on site to achieve start\/stop operation; \u003cbr\u003e\n14.    Automatic re-closing;\u003cbr\u003e\n15.    Closing output signal can be set as on intervals or as continuous output;\u003cbr\u003e\n16.    Applicable for 3 isolated neutral line;\u003cbr\u003e\n17.    Real-time clock (RTC); event log function (event log can record 200 items circularly);\u003cbr\u003e\n18.    Scheduled routing run \u0026amp; scheduled not run (can be set as start genset once a day\/week\/month whether with load or not);\u003cbr\u003e\n19.    Can control two generators to work as cycle run mode, master run mode and balance run mode; \u003cbr\u003e\n20.    Widely DC power supply range allows the controller can bear instantaneous 80V DC input;\u003cbr\u003e\n21.    Large terminal space allows the controller can bear maximum 625V AC voltage input;\u003cbr\u003e\n22.    With Dual-RS485 isolated communication interface. With \"remote controlling, remote measuring, remote communication, remote regulating\" function by the ModBus-RTU communication protocol. Can remote start\/stop the genset and remote control the breaker to close or open; \u003cbr\u003e\n23.    Suitable for various AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire);\u003cbr\u003e\n24.    Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting，compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":29024664551458,"sku":"HAT833","price":1468.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/4a202b0f-07ad-5608-90e4-e17482e3dc78.jpg?v=1562267612"},{"product_id":"smartgen-hat832-three-power-ats-controller","title":"SmartGen HAT832 Three Power ATS controller","description":"\u003cp\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003cbr\u003e\nDisplay  LCD(240*128)\u003cbr\u003e\nLanguage  Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input  8\u003cbr\u003e\nProgrammable Output  12\u003cbr\u003e\nAC System  1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency  50\/60Hz\u003cbr\u003e\nVolt Freq Protection  ●\u003cbr\u003e\nCurrent and Power Display  ●\u003cbr\u003e\nOver Current Warn  ●\u003cbr\u003e\nMonitor Interface  USB\/RS485-1\/RS485-2\u003cbr\u003e\nProgrammable Interface  USB\/RS485-1\/RS485-2\u003cbr\u003e\nRTC(Real Time Clock)  ●\u003cbr\u003e\nScheduled Start Genset  ●\u003cbr\u003e\nCirculate Start Genset  ●\u003cbr\u003e\nSwitch Over Priority  ●\u003cbr\u003e\nDC Supply  DC(8～35)V\/AC(90-305V)\u003cbr\u003e\nCase Dimensions(mm)  260*180*54\u003cbr\u003e\nPanel Cutout(mm)  242*161\u003cbr\u003e\nOperating Temp.  (-25~+70)℃\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHAT832 Three Power ATS controller (Dual-ATS) is intelligent tri-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digitization, intelligence and networking. Automatic measurement and control can reduce incorrect operation, which is an ideal option for ATS.\u003c\/p\u003e\n\n\u003cp\u003eThe powerful Microprocessor contained within the unit allows for precision voltage (3-way 3-phase) measuring and make accurate judgment and the corresponding volt free digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase, phase sequence wrong and other abnormal condition occurs. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electric device and automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc. \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e1.    System type can set as: Mains-Gen-Mains, Gen-Mains-Mains, Mains-Mains-Mains, Gen-Gen-Mains, Mains-Gen-Gen, Gen-Mains-Gen, and Mains-Mains-Gen;\u003cbr\u003e\n2.    4.3 inchs solid color 240x128 LCD display with white backlight, multilingual interface (including English, Simplified Chinese, Other), push-button operation; \u003cbr\u003e\n3.    Collect and display 3-way 3-phase voltage, frequency and phase sequence;\u003cbr\u003e\n4.    Collect and display load active power, reactive power, apparent power, power factor and current;\u003cbr\u003e\n5.    S1\/S2\/S3 separated over current warning\/ trip alarm;\u003cbr\u003e\n6.    NEL (Non-essential Load) trip function;\u003cbr\u003e\n7.    Display S1\/S2\/S3 total kW energy, total kvar energy, total close times;\u003cbr\u003e\n8.    Display continuous power supply time and S1\/S2\/S3 total power supply time;\u003cbr\u003e\n9.    For Stored-Energy type ATS, its close relay will active after the PF Input is active; \u003cbr\u003e\n10.    Over\/under voltage, over\/under frequency, over current, loss of phase, phase sequence wrong protection; \u003cbr\u003e\n11.    Automatic\/Manual mode. In manual mode, can force the switch to close or open;\u003cbr\u003e\n12.    All parameters can be set on site. Passwords authentication ensures authorized staff operation only; \u003cbr\u003e\n13.    The genset can be manual test on site to achieve start\/stop operation; \u003cbr\u003e\n14.    Automatic re-closing;\u003cbr\u003e\n15.    Closing output signal can be set as on intervals or as continuous output;\u003cbr\u003e\n16.    Applicable for 3 isolated neutral line;\u003cbr\u003e\n17.    Real-time clock (RTC); event log function (event log can record 200 items circularly);\u003cbr\u003e\n18.    Black box function, which can cycle record 5 pieces of log and each log contains 60 groups of data including breaker state detailed data of 50s before and 10s after switchover;\u003cbr\u003e\n19.    Scheduled routing run \u0026amp; scheduled not run (can be set as start genset once a day\/week\/month whether with load or not);\u003cbr\u003e\n20.    Can control two generators to work as cycle run mode, master run mode and balance run mode; \u003cbr\u003e\n21.    Widely DC power supply range allows the controller can bear instantaneous 80V DC input;\u003cbr\u003e\n22.    Large terminal space allows the controller can bear maximum 625V AC voltage input;\u003cbr\u003e\n23.    With Dual-RS485 isolated communication interface. With \"remote controlling, remote measuring, remote communication, remote regulating\" function by the ModBus-RTU communication protocol. Can remote start\/stop the genset and remote control the breaker to close or open; \u003cbr\u003e\n24.    Suitable for various AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire);\u003cbr\u003e\n25.    Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting，compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":29024664944674,"sku":"HAT832","price":1292.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/de09c358-258f-5630-a5d7-8e3ac1ff8612.jpg?v=1562267625"},{"product_id":"smartgen-hat560nb-ats-controller-ac-dc-power-supply","title":"SMARTGEN HAT560NB Dual Power ATS Controller","description":"\u003cp\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003cbr\u003e\nDisplay  LCD(132*64)\u003cbr\u003e\nLanguage  Chinese \u0026amp; English\u003cbr\u003e\nAC System  1P2W\/2P3W\/3P4W\u003cbr\u003e\nAlternator Frequency  50\/60Hz\u003cbr\u003e\nMonitor Interface  LINK\u003cbr\u003e\nProgrammable Interface  LINK\u003cbr\u003e\nRTC(Real Time Clock)  ●\u003cbr\u003e\nScheduled Start Genset  ●\u003cbr\u003e\nCirculate Start Genset  ●\u003cbr\u003e\nSwitch Over Priority  ●\u003cbr\u003e\nApplicable Switch Type  PC Two-stage, PC Three-stage, CB and CC switch\u003cbr\u003e\nDC Suppl  DC(8-35)V\u003cbr\u003e\nCase Dimensions(mm)  139*120*48\u003cbr\u003e\nPanel Cutout(mm)  130*111\u003cbr\u003e\nOperating Temp.  (-25~+70)℃\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHAT560N series ATS controller is intelligent dual-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digital, intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003c\/p\u003e\n\n\u003cp\u003eThe powerful Microprocessor contained within the unit allows for precision voltage (2-way-3-phase\/single phase) measuring and make accurate judgment; in addition, the corresponding digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase and other abnormal condition occurs. This controller has full consideration in various application of ATS (automatic transfer system) and can be directly used for specialized ATS, Contactor ATS, Air break ATS etc. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical devices, automatic control and testing system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e1. System type can set as: Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#).\u003cbr\u003e\n2. 132x64 LCD with backlight, optional Chinese and English display, push-button operation.\u003cbr\u003e\n3. Measure and display 2-way 3 phase Voltage and Frequency:\u003cbr\u003e\n4. Over\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection.\u003cbr\u003e\n5. Automatic\/Manual mode. In manual mode, can force the switch to close or open;\u003cbr\u003e\n6. All parameters can be set on site. With Two different passwords which ensures authorized staff operation only.\u003cbr\u003e\n7. During commissioning, the genset can be set either on On-load or Off-load mode.\u003cbr\u003e\n8. ATS Controller has function of automatic Re-closing.\u003cbr\u003e\n9. Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n10. Applicable for ATS of one neutral position, two neutral position and non-position.\u003cbr\u003e\n11. Applicable for 2 isolated neutral line.\u003cbr\u003e\n12. Real-time clock (RTC).\u003cbr\u003e\n13. Event log can record 50 items circularly.\u003cbr\u003e\n14. Scheduled start \u0026amp; stop generator (can be set as start genset once a day\/week\/month whether with load or not).\u003cbr\u003e\n15. Can control two generators to work in a cycle, even the genset running time and crank rest time can be set.\u003cbr\u003e\n16. Optional AC system or DC system.\u003cbr\u003e\n17. With standard LINK communication interface. With \"remote controlling, remote measuring, remote communication\" function by the ModBus communication protocol. Can remote start\/stop the genset and remote control the ATS to close or open.\u003cbr\u003e\n18.Can check the current status of controller (digital input port, digital output port, over voltage, under voltage, over frequency, under frequency etc.).\u003cbr\u003e\n19.Suitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003cbr\u003e\n20. Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting，compact structure with easy installation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n \u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":29024666550306,"sku":"GH-AF9K-LXOW","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/513daaef-85d5-5f10-90af-0155340c86ca.jpg?v=1562267669"},{"product_id":"smartgen-hat160-automatic-transfer-switch-controller-ats-230-400vac-50hz","title":"SMARTGEN HAT160 Dual Power ATS Controller","description":"\u003cp\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003cbr\u003e\nDisplay    LED\u003cbr\u003e\nAC System    1P2W\/3P4W\u003cbr\u003e\nAlternator Voltage    (170～277)V(ph-N)\u003cbr\u003e\nAlternator Frequency    50\/60Hz\u003cbr\u003e\nMonitor Interface    LINK\u003cbr\u003e\nProgrammable Interface    LINK\u003cbr\u003e\nSwitch Over Priority    ●\u003cbr\u003e\nApplicable Switch Type    One Motor Operation\u003cbr\u003e\nCase Dimensions(mm)    87*158*120(L*W*H)\u003cbr\u003e\nPanel Cutout(mm)    74*144\u003cbr\u003e\nOperating Temp.    (-25～+70)℃\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHAT160 ATS Controller is suitable for CB ATS of single motor. It can accurately detect 2-way-3-phase 4-wire\/single-phase 2-wire voltage and judge voltage abnormal (such as, over voltage, under voltage, over frequency, under frequency and lack of phase), then control ATS after delay. When ATS switch abnormally, the controller can detect close\/open failure and alarm on the front panel to ensure the correct action of ATS. After abnormal of I# power, the controller will send signal to start the genset. The controller has remote communication, remote control and parameter configuration functions via LINK port communication.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\nHAT160 controller can detect 2-way (2-way mains and 2-way gens or 1-way mains and 1-way gens) 3-phase\/single phase voltage and control ATS.\u003cbr\u003e\n- Measure and display 2-way 3 phase Voltage and Frequency:\u003cbr\u003e\n- Over\/under voltage, over\/under frequency and loss of phase protection (active or deactive can be configured);\u003cbr\u003e\n- Close\/Open failure alarm;\u003cbr\u003e\n- LED display work status;\u003cbr\u003e\n- Auto\/Manual mode. In manual mode, ATS can be switched by pressing front panel button;\u003cbr\u003e\n- Applicable for 2 isolated neutral line.\u003cbr\u003e\n- Automatic Re-closing;\u003cbr\u003e\n- Close delay, delay is 0.5s;\u003cbr\u003e\n- Any one way of A phase voltage is normal, the controller and ATS can normally work. When 2-way power and volts are abnormal at the same time, if any way of A phase voltage is normal, ATS will automatically transfer to Breaking (Middle) Position;\u003cbr\u003e\n- Fire reset interface. When the input port is enabled, ATS will automatically transfer to Breaking (OFF) Position;\u003cbr\u003e\n- Parameter setting: parts of parameters can be adjust from front panel; all can be adjust via LINK port(with SG72A adaptor) by using computer software;\u003cbr\u003e\n- Digitization adjustment of parameters (abandon simulation adjustment, enhanced reliability and stability);\u003cbr\u003e\n- Strong anti-electromagnetic interference ability, can be used under complex electromagnetic interference environment;\u003cbr\u003e\n- Modular design, self extinguishing ABS plastic shell, pluggable terminal, compact structure;\u003cbr\u003e\n- Three installation ways: panel built-in, internal 35mm slideway and internal screw mounting.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":29024667172898,"sku":"D7-EG9D-QWRR","price":97.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/7decbf27-51fd-55c3-b208-a0eed8342bc1.jpg?v=1562267713"},{"product_id":"smartgen-hat700bi-ats-controller-current-measurement-ac-dc-power-supply","title":"SMARTGEN HAT700BI Dual Power ATS Controller","description":"\u003cp\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003cbr\u003e\nDisplay  LCD(132*64)\u003cbr\u003e\nLanguage  Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nAC System  1P2W\/2P3W\/3P4W\u003cbr\u003e\nAlternator Frequency  50\/60Hz\u003cbr\u003e\nkW Detecting \u0026amp; Display  ●\u003cbr\u003e\nMonitor Interface  RS485\u003cbr\u003e\nProgrammable Interface  LINK\/RS485\u003cbr\u003e\nRTC(Real Time Clock)  ●\u003cbr\u003e\nScheduled Start Genset  ●\u003cbr\u003e\nCirculate Start Genset  ●\u003cbr\u003e\nSwitch Over Priority  ●\u003cbr\u003e\nApplicable Switch Type  PC Two-stage, PC Three-stage, CB and CC switch\u003cbr\u003e\nDC Supply  DC(8-35)V\u003cbr\u003e\nCase Dimensions(mm)  197*152*47\u003cbr\u003e\nPanel Cutout(mm)  186*141\u003cbr\u003e\nOperating Temp.  (-25~+70)℃\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\n\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHAT700 series ATS controller is intelligent dual-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digital, intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003cbr\u003e\nThe powerful Microprocessor contained within the unit allows for precision voltage (2-way-3-phase) measuring and make accurate judgment; in addition, the corresponding digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase and other abnormal condition occurs. This controller has full consideration in various application of ATS (automatic transfer system) and can be directly used for PC ATS, CB ATS, CC ATS etc. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical devices, automatic control and testing system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e PERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003cbr\u003e\n1. System type can set as: S1 (Mains) \u0026amp; S2 (Mains), S1 (Mains) \u0026amp; S2 (Generator), S1 (Generator) \u0026amp; S2 (Mains), S1 (Generator) \u0026amp; S2 (Generator).\u003cbr\u003e\n2. 132x64 LCD with backlight, multilingual interface (including English, Chinese or other languages), push-button operation.\u003cbr\u003e\n3. Collect and display 2-way 3-phase Voltage, Frequency and Phase.\u003cbr\u003e\n4. Collect and display Active Power, Reactive Power, Apparent Power, Power Factor and Current.\u003cbr\u003e\n5. S1\/S2 separated over current warning\/ trip alarm.\u003cbr\u003e\n6. NEL (Non-essential Load) trip function.\u003cbr\u003e\n7. Display S1\/S2 Total kW Energy, Total kvar Energy, Total Close Times.\u003cbr\u003e\n8. Display continuous power supply time and S1\/S2 total power supply time.\u003cbr\u003e\n9. Sync Transfer function; in addition, Voltage Difference, Frequency Difference and Phase Difference can be displayed. \u003cbr\u003e\n10. For Stored-Energy type ATS, its close relay will active after the PF Input is active. \u003cbr\u003e\n11. Over\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection. \u003cbr\u003e\n12. Phase Sequence Transfer function.\u003cbr\u003e\n13. Automatic\/Manual mode. In manual mode, can force the switch to close or open;\u003cbr\u003e\n14. All parameters can be set on site. Passwords authentication ensures authorized staff operation only. \u003cbr\u003e\n15. The genset can be Manual Test on site to achieve start\/stop operation. \u003cbr\u003e\n16. ATS Controller has function of automatic Re-closing.\u003cbr\u003e\n17. Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n18. Applicable for PC Three-stage, PC Two-stage, CB and CC switch. \u003cbr\u003e\n19. Applicable for 2 isolated neutral line.\u003cbr\u003e\n20. Real-time clock (RTC); Event log Function (Event log can record 99 items circularly).\u003cbr\u003e\n21. Scheduled Run \u0026amp; Scheduled Not Run (can be set as start genset once a day\/week\/month whether with load or not).\u003cbr\u003e\n22. Can control two generators to work as Cycle Run mode, Master Run mode and Balance Run mode. \u003cbr\u003e\n23. Widely power supply range DC(8~35)V allows the controller can bear 80V instantaneous current.\u003cbr\u003e\n24. Large terminal space allows the controller can bear maximum 625V input voltage.\u003cbr\u003e\n25. With RS485 isolated communication interface. With \"remote controlling, remote measuring, remote communication, remote regulating\" function by the ModBus communication protocol. Can remote start\/stop the genset and remote control the ATS to close or open. \u003cbr\u003e\n26. Suitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003cbr\u003e\n27. Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting，compact structure with easy installation.\u003cbr\u003e\n \u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":29024669171746,"sku":"0B-7Z0I-19N9","price":436.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/500fbe89-bdce-5b56-8f47-a53a3c281fcd.jpg?v=1562267781"},{"product_id":"smartgen-hatc60-ats-controller-ac-dc-power-supply-designed-for-socomec-ats","title":"SmartGen HATC60 ATS controller designed for Socomec ATS","description":"\u003cp\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003cbr\u003e\nDisplay  LCD(132*64)\u003cbr\u003e\nLanguage  Chinese \u0026amp; English\u003cbr\u003e\nProgrammable Output  4\u003cbr\u003e\nAC System  1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency  50\/60Hz\u003cbr\u003e\nMonitor Interface  RS485\u003cbr\u003e\nRTC(Real Time Clock)  ●\u003cbr\u003e\nDC Supply  DC(12-48)V\u003cbr\u003e\nCase Dimensions(mm)  163*133*51\u003cbr\u003e\nPanel Cutout(mm)  152*122\u003cbr\u003e\nOperating Temp.  (-25~+70)℃\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHATC60 dual power automatic shift controller is the intelligent dual-power switchover module with configurable function, automatic measurement, LCD display, and digital communication. It combines digitization, intelligence and networking together. Measurement and control process can be conducted automatically, which reduces artificial operating mistakes, so that it is the ideal option for dual-power switchover products.\u003c\/p\u003e\n\n\u003cp\u003eHATC60 dual power ATS controller is composed by the powerful microprocessor in the core, which can precisely measure the voltages (2-way 3-phase) and make accurate decision for abnormal voltages (overvoltage, undervoltage, overfrequency, underfrequency, phase loss, reverse phase sequence), and putout power-off control switch signal. This device is dedicated for Socomec ATS switch. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building and etc. \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003cbr\u003e\n1. System type can be set as Mains-Power Generation, Mains-Mains, Power Generation-Power Generation etc.; \u003cbr\u003e\n2. Suitable for multiple AC system types (3-phase 4-line, 3-phase 3-line, 1-phase 2-line, 2-phase 3-line methods); \u003cbr\u003e\n3. Equipped with single color LCD screen with 132x64 pixel and bilingual display (Simplized Chinese, English), and tuch-button operation; \u003cbr\u003e\n4. Able to collect and display 2-way 3-phase voltage, frequency and phase sequence; \u003cbr\u003e\n5. Equipped with overvoltage, Undervoltage, overfrequency, underfrequency, phase loss, reverse phase sequence functions; \u003cbr\u003e\n6. Equipped with display function of accumulated S1\/S2 breaker-close times; \u003cbr\u003e\n7. Equipped with display function of current lasting power supply time and accumulated S1\/S2 power supply time; \u003cbr\u003e\n8. Equipped with Auto\/Manual status switchover function. Under manual status switch breaker close and open can be controlled artificially; .\u003cbr\u003e\n9. All parameters can be configured on the spot. Password verification is employed in case of wrong operation by non-professionals; \u003cbr\u003e\n10 Artificial machine test is available on the spot for genset Start\/Stop operation; \u003cbr\u003e\n11. Equipped with switch breaker re-close function; \u003cbr\u003e\n12. Breaker close output can be set as pulse or continuous output; \u003cbr\u003e\n13. Equipped with separated 2-way N-wire design; \u003cbr\u003e\n14. Equipped with real-time clock display function, and event log function which can record 200 items circularly; \u003cbr\u003e\n15. Equipped with timing inspection Start\/timing No-start function for genset, which can be set for once running, monthly running, or weekly running and running with loading or not can be set for all of them; \u003cbr\u003e\n16. Able to control two generators, which realizes circular running, primary running, and balanced time running; \u003cbr\u003e\n17. Wide DC power supply range, which allows the controller bear instantaneous 80V DC input at most; \u003cbr\u003e\n18. Large space between AC input terminals which allows the controller to bear maximum 625V input; \u003cbr\u003e\n19. One RS485 isolated communication interface is designed. It applys ModBus-RTU communication protocol and has remote control, remote communication, remote measuring, remote regulating functions. It can remotely control genset Start, Stop, switch breaker close and open functions; \u003cbr\u003e\n20. Modular structure design, flame retarding ABS shell, pluggable connecting terminal, and embedded installation method, with compact structure and convenient installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":31591507689514,"sku":"HATC60","price":174.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/157e3972-d2ee-5f05-8e10-e18bbd013285.jpg?v=1589363926"},{"product_id":"smartgen-hat600n-ats-controller","title":"SmartGen HAT600N Dual Power ATS Controller","description":"\u003cp\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003cbr\u003e\nDisplay LCD(128*64)\u003cbr\u003e\nLanguage Chinese\/English\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface LINK\/RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSwitch Over Priority ●\u003cbr\u003e\nApplicable Switch Type All types\u003cbr\u003e\nDC Supply DC(8～35)V\u003cbr\u003e\nCase Dimensions(mm) 209*153*55(L*W*H)\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)℃\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHAT600N series ATS controller is intelligent dual-supply module with programmable function, automatic measurement, LCD display, and digital communication. It combines digital intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003cbr\u003e\n\u003cbr\u003e\nHAT600N series ATS controller is made of microprocessor as its core, can accurately detect extended-spectrum 2-way-3-phase voltage and also make accurate judgment and output passive control switch under the abnormal voltage (over and under voltage, miss phase and over and under frequency). This controller has full consideration in various application of ATS (automatic transfer system) can be directly used for Intelligent ATS, Contactor ATS, Circuit Break ATS etc. It have compact structure, advanced circuits, simple wiring and high reliability, be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003cbr\u003e\n1) System type can set for: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#).\u003cbr\u003e\n2) Backlit 128x64 LCD, optional Chinese and English display, push-button operation.\u003cbr\u003e\n3) Measure and display 2-way 3 phase Voltage and Frequency:\u003cbr\u003e\n4) Measure and display active power, apparent power, power factor and 3 phase current;\u003cbr\u003e\n5) Over current alarm;\u003cbr\u003e\n6) Over\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection.\u003cbr\u003e\n7) Automatic\/Manual mode. In manual mode, can force switch to close or open;\u003cbr\u003e\n8) All parameters can be set on site. With Two different passwords which ensures authorized staff operation only.\u003cbr\u003e\n9) During genset testing ATS controller can be set either on On-load or Off-load mode.\u003cbr\u003e\n10) ATS Controller has function of automatic Re-closing.\u003cbr\u003e\n11) Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n12) Applicable for ATS of one neutral position, two neutral position and change over.\u003cbr\u003e\n13) Applicable for 2 isolated neutral line for Generator and Mains.\u003cbr\u003e\n14) Real-time clock (RTC).\u003cbr\u003e\n15) Event log can record 99 items circularly.\u003cbr\u003e\n16) Timely schedule can be set on monthly or weekly basis and trial can be set as with on- load or off -load.\u003cbr\u003e\n17) Can control two generators to work in a cycle, even the genset running time and crank rest time can be set.\u003cbr\u003e\n18) Widely range of DC power supply (8V to 35V). Max.80V DC input can be endured in an instant, or be supplied via HWS560 module (input AC 85V~560V, output DC 12V).\u003cbr\u003e\n19) Wide space between connecting terminals of AC input. Max.625V input voltage.\u003cbr\u003e\n20) With standard isolated RS485 communication interface. With \"remote controlling, remote measuring, remote communication\" function by the ModBus communication protocol.\u003cbr\u003e\n21) Can check the current status of controller (including switch digital input, over Voltage, and under Voltage etc.).\u003cbr\u003e\n22) Suitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003cbr\u003e\n23) Modular design, flame-resisting ABS plastic shell, plug-in terminals and embedded installation. Compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":41961620111531,"sku":"HAT600N-SMRTGN","price":262.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/8ad783f9-19ee-597a-8f35-fe1cf73f1314.jpg?v=1657800009"},{"product_id":"smartgen-hat700b-ats-controller","title":"SmartGen HAT700B Dual Power ATS Controller","description":"\u003cp\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface LINK\/RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSwitch Over Priority ●\u003cbr\u003e\nApplicable Switch Type PC Two-stage, PC Three-stage, CB and CC switch\u003cbr\u003e\nDC Supply DC(8-35)V\u003cbr\u003e\nCase Dimensions(mm) 197*152*47\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)℃\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHAT700 series ATS controller is intelligent dual-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digital, intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003cbr\u003e\n\u003cbr\u003e\nThe powerful Microprocessor contained within the unit allows for precision voltage (2-way-3-phase) measuring and make accurate judgment; in addition, the corresponding digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase and other abnormal condition occurs. This controller has full consideration in various application of ATS (automatic transfer system) and can be directly used for PC ATS, CB ATS, CC ATS etc. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical devices, automatic control and testing system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003cbr\u003e\n1. System type can set as: S1 (Mains) \u0026amp; S2 (Mains), S1 (Mains) \u0026amp; S2 (Generator), S1 (Generator) \u0026amp; S2 (Mains), S1 (Generator) \u0026amp; S2 (Generator).\u003cbr\u003e\n2. 132x64 LCD with backlight, multilingual interface (including English, Chinese or other languages), push-button operation.\u003cbr\u003e\n3. Collect and display 2-way 3-phase Voltage, Frequency and Phase.\u003cbr\u003e\n4. Collect and display Active Power, Reactive Power, Apparent Power, Power Factor and Current.\u003cbr\u003e\n5. S1\/S2 separated over current warning\/ trip alarm.\u003cbr\u003e\n6. NEL (Non-essential Load) trip function.\u003cbr\u003e\n7. Display S1\/S2 Total kW Energy, Total kvar Energy, Total Close Times.\u003cbr\u003e\n8. Display continuous power supply time and S1\/S2 total power supply time.\u003cbr\u003e\n9. Sync Transfer function; in addition, Voltage Difference, Frequency Difference and Phase Difference can be displayed.\u003cbr\u003e\n10. For Stored-Energy type ATS, its close relay will active after the PF Input is active.\u003cbr\u003e\n11. Over\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection.\u003cbr\u003e\n12. Phase Sequence Transfer function.\u003cbr\u003e\n13. Automatic\/Manual mode. In manual mode, can force the switch to close or open;\u003cbr\u003e\n14. All parameters can be set on site. Passwords authentication ensures authorized staff operation only.\u003cbr\u003e\n15. The genset can be Manual Test on site to achieve start\/stop operation.\u003cbr\u003e\n16. ATS Controller has function of automatic Re-closing.\u003cbr\u003e\n17. Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n18. Applicable for PC Three-stage, PC Two-stage, CB and CC switch.\u003cbr\u003e\n19. Applicable for 2 isolated neutral line.\u003cbr\u003e\n20. Real-time clock (RTC); Event log Function (Event log can record 99 items circularly).\u003cbr\u003e\n21. Scheduled Run \u0026amp; Scheduled Not Run (can be set as start genset once a day\/week\/month whether with load or not).\u003cbr\u003e\n22. Can control two generators to work as Cycle Run mode, Master Run mode and Balance Run mode.\u003cbr\u003e\n23. Widely power supply range DC(8~35)V allows the controller can bear 80V instantaneous current.\u003cbr\u003e\n24. Large terminal space allows the controller can bear maximum 625V input voltage.\u003cbr\u003e\n25. With RS485 isolated communication interface. With \"remote controlling, remote measuring, remote communication, remote regulating\" function by the ModBus communication protocol. Can remote start\/stop the genset and remote control the ATS to close or open.\u003cbr\u003e\n26. Suitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003cbr\u003e\n27. Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting，compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":41961622798507,"sku":"HAT700B-SMRTGN","price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/22515bb0-8d1e-534c-b54a-044d97454355.jpg?v=1657800165"},{"product_id":"smartgen-hat700s-ats-controller","title":"SmartGen HAT700S Dual Power ATS Controller","description":"\u003cp\u003e\u003cstrong\u003eTechnical Parameters\u003c\/strong\u003e:\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P4W\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface LINK\/RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSwitch Over Priority ●\u003cbr\u003e\nApplicable Switch Type PC Two-stage, PC Three-stage, CB and CC switch\u003cbr\u003e\nSync Transfer ●\u003cbr\u003e\nDC Supply DC(8-35)V\u003cbr\u003e\nCase Dimensions(mm) 197*152*47\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)℃\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHAT700 series ATS controller is intelligent dual-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digital, intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003cbr\u003e\n\u003cbr\u003e\nThe powerful Microprocessor contained within the unit allows for precision voltage (2-way-3-phase) measuring and make accurate judgment; in addition, the corresponding digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase and other abnormal condition occurs. This controller has full consideration in various application of ATS (automatic transfer system) and can be directly used for PC ATS, CB ATS, CC ATS etc. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical devices, automatic control and testing system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS:\u003c\/strong\u003e\u003cbr\u003e\n1. System type can set as: S1 (Mains) \u0026amp; S2 (Mains), S1 (Mains) \u0026amp; S2 (Generator), S1 (Generator) \u0026amp; S2 (Mains), S1 (Generator) \u0026amp; S2 (Generator).\u003cbr\u003e\n2. 132x64 LCD with backlight, multilingual interface (including English, Chinese or other languages), push-button operation.\u003cbr\u003e\n3. Collect and display 2-way 3-phase Voltage, Frequency and Phase.\u003cbr\u003e\n4. Collect and display Active Power, Reactive Power, Apparent Power, Power Factor and Current.\u003cbr\u003e\n5. S1\/S2 separated over current warning\/ trip alarm.\u003cbr\u003e\n6. NEL (Non-essential Load) trip function.\u003cbr\u003e\n7. Display S1\/S2 Total kW Energy, Total kvar Energy, Total Close Times.\u003cbr\u003e\n8. Display continuous power supply time and S1\/S2 total power supply time.\u003cbr\u003e\n9. Sync Transfer function; in addition, Voltage Difference, Frequency Difference and Phase Difference can be displayed.\u003cbr\u003e\n10. For Stored-Energy type ATS, its close relay will active after the PF Input is active.\u003cbr\u003e\n11. Over\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection.\u003cbr\u003e\n12. Phase Sequence Transfer function.\u003cbr\u003e\n13. Automatic\/Manual mode. In manual mode, can force the switch to close or open;\u003cbr\u003e\n14. All parameters can be set on site. Passwords authentication ensures authorized staff operation only.\u003cbr\u003e\n15. The genset can be Manual Test on site to achieve start\/stop operation.\u003cbr\u003e\n16. ATS Controller has function of automatic Re-closing.\u003cbr\u003e\n17. Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n18. Applicable for PC Three-stage, PC Two-stage, CB and CC switch.\u003cbr\u003e\n19. Applicable for 2 isolated neutral line.\u003cbr\u003e\n20. Real-time clock (RTC); Event log Function (Event log can record 99 items circularly).\u003cbr\u003e\n21.Scheduled Run \u0026amp; Scheduled Not Run (can be set as start genset once a day\/week\/month whether with load or not).\u003cbr\u003e\n22. Can control two generators to work as Cycle Run mode, Master Run mode and Balance Run mode.\u003cbr\u003e\n23. Widely power supply range DC(8~35)V allows the controller can bear 80V instantaneous current.\u003cbr\u003e\n24. Large terminal space allows the controller can bear maximum 625V input voltage.\u003cbr\u003e\n25. With RS485 isolated communication interface. With \"remote controlling, remote measuring, remote communication, remote regulating\" function by the ModBus communication protocol. Can remote start\/stop the genset and remote control the ATS to close or open.\u003cbr\u003e\n26. Suitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003cbr\u003e\n27.Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting，compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":41961668935851,"sku":"HAT700S-SMRTGN","price":612.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/22515bb0-8d1e-534c-b54a-044d97454355_0049bf1f-4425-451c-9ffc-ab054c50251c.jpg?v=1657803035"},{"product_id":"smartgen-hat821-dual-power-bus-tie-controller","title":"SmartGen HAT821 Dual Power Bus Tie controller","description":"\u003cp\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003cbr\u003e\nDisplay LCD(240*128)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 8\u003cbr\u003e\nProgrammable Output 12\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nVolt Freq Protection ●\u003cbr\u003e\nMonitor Interface USB\/RS485-1\/RS485-2\u003cbr\u003e\nProgrammable Interface USB\/RS485-1\/RS485-2\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nDC Supply DC(8～35)V\u003cbr\u003e\nCase Dimensions(mm) 260*180*54\u003cbr\u003e\nPanel Cutout(mm) 242*161\u003cbr\u003e\nOperating Temp. (-25~+70)℃\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHAT821 Dual Power Bus Tie controller is intelligent bus-tie dual-power switchover module with configurable function, automatic measurement, LCD display, and digital communication. It combines digitization, intelligence and networking. Automatic measurement and control can reduce incorrect operation, which is an ideal option for dual-power bus-tie switchover products.\u003cbr\u003e\n\u003cbr\u003e\nThe powerful Microprocessor contained within the unit allows for precision voltage (2-way 3-phase) measuring and make accurate judgment and the corresponding volt free digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase, phase sequence wrong and other abnormal condition occurs. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n1. 4.3 inchs solid color 240x128 LCD display with white backlight, multilingual interface (including English, simplified Chinese or other languages), push-button operation;\u003cbr\u003e\n2. Collect and display 2-way 3-phase voltage, frequency and phase;\u003cbr\u003e\n3. Display S1\/S2 total close times;\u003cbr\u003e\n4. Display load 1 and load 2 present continuous power supply time and total power supply time;\u003cbr\u003e\n5. Display S1\/S2 total power supply time;\u003cbr\u003e\n6. Over\/under voltage, over\/under frequency, loss of phase, phase sequence wrong protection;\u003cbr\u003e\n7. Real-time clock (RTC); event log function (event log can record 200 items circularly);\u003cbr\u003e\n8. Suitable for various AC systems (3- phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire);\u003cbr\u003e\n9. Simultaneously control the closing and opening of the two-way CB switch and the bus-tie CB switch to simplify the control system;\u003cbr\u003e\n10. For Stored-Energy type ATS, its close relay will active after the PF Input is active;\u003cbr\u003e\n11. Automatic\/Manual mode. In manual mode, can force the switch to close or open;\u003cbr\u003e\n12. 6 buttons on the panel to manually control breaker switch easily;\u003cbr\u003e\n13. With breaker re-close function;\u003cbr\u003e\n14. Closing output signal can be set as on intervals or as continuous output, which suitable for CB breaker or CC contactor;\u003cbr\u003e\n15. All parameters can be set on site. Passwords authentication ensures authorized staff operation only;\u003cbr\u003e\n16. Applicable for 2 isolated neutral line;\u003cbr\u003e\n17. Enabling switch power supply LO\/NO output to provide power for switching coil;\u003cbr\u003e\n18. Widely DC power supply range allows the controller can bear instantaneous 80V DC input;\u003cbr\u003e\n19. Large terminal space allows the controller can bear maximum 625V AC voltage input;\u003cbr\u003e\n20. With Dual-RS485 isolated communication interface. With \"remote controlling, remote measuring, remote communication, remote regulating\" function by the ModBus communication protocol. Can remote start\/stop the genset and remote control the breaker to close or open;\u003cbr\u003e\n21. USB is convenient to debug parameters and upgrade program locally;\u003cbr\u003e\n22. Modular design, self extinguishing ABS shell, silicone panel, pluggable terminal, built-in mounting, compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":41961686794411,"sku":"HAT821","price":1224.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/750b847e-df72-55a5-b5ad-72bf3a9b6342.jpg?v=1657804701"},{"product_id":"smartgen-hat860-medium-voltage-ats-controller","title":"SmartGen HAT860 Medium Voltage ATS Controller","description":"\u003cp\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\nDisplay LCD(240*128)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 12\u003cbr\u003e\nProgrammable Output 13\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nVolt Freq Protection ?\u003cbr\u003e\nCurrent and Power Display ?\u003cbr\u003e\nOver Current Warn ?\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\u003cbr\u003e\nRTC(Real Time Clock) ?\u003cbr\u003e\nScheduled Start Genset ?\u003cbr\u003e\nCirculate Start Genset ?\u003cbr\u003e\nDC Supply DC(8~60)V\u003cbr\u003e\nCase Dimensions(mm) 260*180*54\u003cbr\u003e\nPanel Cutout(mm) 242*161\u003cbr\u003e\nOperating Temp. (-25~+70)?\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHAT860 Medium Voltage ATS Controller is a module that integrates programmable function, automatic measurement, PT break detection, load stepwise switch, LCD display and digital communication. It combines digital, intelligent and network technology, realizes automation of measurement and control process, thus reducing manual operation error, which is an ideal product for medium voltage dual power transfer.\u003cbr\u003e\n\u003cbr\u003e\nHAT860 Medium Voltage ATS Controller is composed of microprocessor as the core, which can precisely detect 2-way 3-phase incoming voltage, make accurate judgment for voltage abnormal situations (over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence) and output passive control coil. With compact structure, advanced circuits, simple wiring and high reliability, it can be widely used in the electric automatic control system of electric power, telecom, petrochemical industry, mining, railways, municipal administration, data center, intelligent building and other industries.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003col\u003e\n\t\u003cli\u003eSystem type can set as: Mains-Mains, Mains-Gen, Gen-Mains, Gen-Gen;\u003c\/li\u003e\n\t\u003cli\u003e4.3-inch single color 240x128 LCD display with white backlight, multilingual interface (Simplified Chinese, English, other), push-button operation;\u003c\/li\u003e\n\t\u003cli\u003eCollect and display 2-way 3-phase voltage, frequency and phase sequence;\u003c\/li\u003e\n\t\u003cli\u003eCollect and display load active power, reactive power, apparent power, power factor and 2-way current;\u003c\/li\u003e\n\t\u003cli\u003ePT break detection function, whether PT wire is broken can be judged by measured voltage and current data and PT break status can be obtained by digital input ports;\u003c\/li\u003e\n\t\u003cli\u003eLoad stepwise switch function, can realize current unit and external stepwise switch control. With current unit stepwise switch control, stepwise switch control of 24 load breakers can be realized, the priority of each load breaker can be flexibly set, close feedback status, work position status, test position status and trip status of each load breaker can be detected;\u003c\/li\u003e\n\t\u003cli\u003eSix 16-way digital input modules and three 16-way digital output modules can be expanded via RS485 interface;\u003c\/li\u003e\n\t\u003cli\u003eBustie control function, suitable for 4-incoming 2-bustie application scheme (realize by two HAT860 modules);\u003c\/li\u003e\n\t\u003cli\u003eEarth fault protection function;\u003c\/li\u003e\n\t\u003cli\u003eS1\/S2 independent overcurrent warning or trip alarm function;\u003c\/li\u003e\n\t\u003cli\u003eForced open, PT break, communication failure, earth fault alarm functions;\u003c\/li\u003e\n\t\u003cli\u003eNEL trip function;\u003c\/li\u003e\n\t\u003cli\u003eDisplay of S1\/S2 accumulated active energy, reactive energy, close times, automatic transfer times, mains failure transfer times;\u003c\/li\u003e\n\t\u003cli\u003eDisplay of current continuous supply time, S1\/S2 accumulated supply time, accumulated auto transfer running time;\u003c\/li\u003e\n\t\u003cli\u003eFor energy storage breaker, it can close after PF (close is ready) signal is active;\u003c\/li\u003e\n\t\u003cli\u003eOver\/under voltage, over\/under frequency, overcurrent, loss of phase, reverse phase sequence function;\u003c\/li\u003e\n\t\u003cli\u003eAuto\/manual transfer, manually control breaker close\/open in manual mode;\u003c\/li\u003e\n\t\u003cli\u003eAll parameters can be configured on site. Passwords authentication ensures authorized staff operation only;\u003c\/li\u003e\n\t\u003cli\u003eManual commissioning to achieve genset start\/stop operation;\u003c\/li\u003e\n\t\u003cli\u003eBreaker re-closing function;\u003c\/li\u003e\n\t\u003cli\u003eClosing output signal can be set as pulse or continuous output;\u003c\/li\u003e\n\t\u003cli\u003e2-way N-wire isolated design;\u003c\/li\u003e\n\t\u003cli\u003eReal-time clock (RTC); event log function (event log can record 200 items circularly);\u003c\/li\u003e\n\t\u003cli\u003eWith black box function, can record 5 groups of events in ATS auto transfer circularly, 60 detailed data of 50s before each event record, and 10s after each event record;\u003c\/li\u003e\n\t\u003cli\u003eScheduled routing run \u0026amp; scheduled not run (can be set as genset start daily\/weekly\/monthly whether with load or not, also can be set some time not run daily\/weekly\/monthly);\u003c\/li\u003e\n\t\u003cli\u003eCan control two gensets to work as cycle run mode, master-slave run mode and balanced time run mode;\u003c\/li\u003e\n\t\u003cli\u003eWide DC power supply range DC(8~60)V allows the controller can bear instantaneous DC 80V input, genset starting battery also can supply power;\u003c\/li\u003e\n\t\u003cli\u003eSupply power can be connected with AC(90~305)V or DC110V, DC220V;\u003c\/li\u003e\n\t\u003cli\u003eMaximum AC 625V voltage input can be accepted;\u003c\/li\u003e\n\t\u003cli\u003eWith Dual-RS485 isolated communication interface. With \"four remote\" (remote control, remote measurement, remote communication, remote adjusting) function by the ModBus-RTU communication protocol. Genset start\/stop and breaker close\/open can be controlled remotely;\u003c\/li\u003e\n\t\u003cli\u003eSuitable for various AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire methods);\u003c\/li\u003e\n\t\u003cli\u003eModular design, anti-flaming ABS plastic shell, pluggable terminal, embedded mounting, compact structure with easy installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42100933296299,"sku":"HAT860","price":1955.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/af3abc00-321f-5183-a09e-1960e9f7bdf7.png?v=1661781941"},{"product_id":"smartgen-hat828-high-speed-ats-controller","title":"SmartGen HAT828 High Speed ATS Controller","description":"\u003cp\u003e\u003cstrong\u003eTechnical Parameters:\u003c\/strong\u003e\u003cbr\u003e\nDisplay LCD(240*128)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 8\u003cbr\u003e\nProgrammable Output 10\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nVolt Freq Protection ?\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface USB\u003cbr\u003e\nRTC(Real Time Clock) ?\u003cbr\u003e\nScheduled Start Genset ?\u003cbr\u003e\nCirculate Start Genset ?\u003cbr\u003e\nSwitch Over Priority ?\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 260*180*54\u003cbr\u003e\nPanel Cutout(mm) 242*161\u003cbr\u003e\nOperating Temp. (-25~+70)?\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003cbr\u003e\nHAT828 High Speed ATS Controller is a dual power transfer module that can output switch transfer signals within 15ms in the case of any power outage, and synchronously transfer when both power supplies are normal. It is suitable for PC two-stage transfer switch (high speed and normal). With embedded operation system, it can precisely detect 2-way 3-phase voltage and make accurate judgment for voltage abnormal situation (over voltage, under voltage, over frequency, under frequency, loss of phase, reverse phase sequence). It also has configurable input\/output, LCD display, digital communication and other functions.\u003cbr\u003e\n\u003cbr\u003e\nHAT828 High Speed ATS Controller combines digitization, intelligence and networking. Automatic measurement and control can reduce incorrect operation, which is an ideal option for dual power transfer. With compact structure, advanced circuits, simple wiring and high reliability, it can be widely used in electric power, post and telecommunication, petroleum, coal, metallurgy, railways, municipal administration, intelligent building and other places with high requirements for power reliability.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003ePERFORMANCE AND CHARACTERISTICS\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003col\u003e\n\t\u003cli\u003eCan complete power outage detection and control signal output within 15ms after power off; with high speed PC two-stage switch, it can realize switching within power outage 20ms;\u003c\/li\u003e\n\t\u003cli\u003eSuitable for PC two-stage transfer switch (normal and high speed);\u003c\/li\u003e\n\t\u003cli\u003eSystem type can set as: Mains-Gen, Gen-Mains, Mains-Mains, Gen-Gen;\u003c\/li\u003e\n\t\u003cli\u003e4.3-inch single color 240x128 LCD display with white backlight, multilingual interface (Simplified Chinese, English, other), other is default as Traditional Chinese, push-button operation;\u003c\/li\u003e\n\t\u003cli\u003eCollect and display 2-way 3-phase voltage, frequency and phase sequence;\u003c\/li\u003e\n\t\u003cli\u003eSynchronous transfer when power is available on both sides (including abnormal situation);\u003c\/li\u003e\n\t\u003cli\u003eDisplay accumulated close times, auto transfer times, mains failure transfer times;\u003c\/li\u003e\n\t\u003cli\u003eDisplay current continuous supply time and S1\/S2 accumulated supply time, auto transfer running time;\u003c\/li\u003e\n\t\u003cli\u003eWith over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence detection function;\u003c\/li\u003e\n\t\u003cli\u003eAuto\/Manual mode transfer. In manual mode, it can manually control switch transfer;\u003c\/li\u003e\n\t\u003cli\u003eAll parameters can be configured on site. Passwords authentication ensures authorized staff operation only;\u003c\/li\u003e\n\t\u003cli\u003eManual commissioning on site to achieve genset start\/stop operation;\u003c\/li\u003e\n\t\u003cli\u003eWith switch re-closing function;\u003c\/li\u003e\n\t\u003cli\u003eClosing output signal can be set as pulse or continuous output;\u003c\/li\u003e\n\t\u003cli\u003e2-way N-wire isolated design;\u003c\/li\u003e\n\t\u003cli\u003eReal-time clock (RTC); event log function (event log can record 200 items circularly);\u003c\/li\u003e\n\t\u003cli\u003eWith black box function, can record 5 groups of events in ATS auto transfer circularly, 60 detailed data of 50s before each event record, and 10s after each event record;\u003c\/li\u003e\n\t\u003cli\u003eScheduled routing run \u0026amp; scheduled not run (can be set as start genset once a day\/week\/month whether with load or not);\u003c\/li\u003e\n\t\u003cli\u003eCan control two gensets to work as cycle run mode, master run mode and balanced run mode;\u003c\/li\u003e\n\t\u003cli\u003eWith customized boot screen function;\u003c\/li\u003e\n\t\u003cli\u003eWidely DC power supply range allows the controller can bear instantaneous DC 80V input;\u003c\/li\u003e\n\t\u003cli\u003eAC power supply can be phase voltage (L-N) or line voltage (L-L), supply range AC(90~576)V;\u003c\/li\u003e\n\t\u003cli\u003eLarge terminal space allows the controller can bear maximum AC 625V voltage input;\u003c\/li\u003e\n\t\u003cli\u003eWith Dual-RS485 isolated communication interface. With \"four remote\" (remote control, remote measurement, remote communication, remote adjusting) function by the ModBus-RTU communication protocol. Genset start\/stop and switch transfer can be controlled remotely;\u003c\/li\u003e\n\t\u003cli\u003eSuitable for various AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire methods);\u003c\/li\u003e\n\t\u003cli\u003eModular design, anti-flaming ABS plastic shell, pluggable terminal, embedded mounting, compact structure with easy installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42100934770859,"sku":"HAT828","price":1955.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/6d0968d8-a1dd-5f8f-abb3-078578ac99b0.png?v=1661782052"},{"product_id":"smartgen-hat880-dual-power-bypass-ats-controller","title":"SmartGen HAT880 Dual power bypass ATS controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(240*128)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nVolt Freq Protection ●\u003cbr\u003e\nCurrent and Power Display ●\u003cbr\u003e\nOver Current Warn ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 260*180*54\u003cbr\u003e\nPanel Cutout(mm) 242*161\u003cbr\u003e\nOperating Temp. (-25~+70)●\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT880 Series Dual Power Bypass ATS Controller is an intelligent dual power bypass switch module which integrates programmable function with automatic measurement, LCD display and digital communication. It is with qualities of digitalization, intelligence, and network. Meansurement and control automation is realized for reducing human operation mistakes, so it is the ideal device for dual power bypass switch.\u003cbr\u003e\n\u003cbr\u003e\nHAT880 Series Dual Power Bypass ATS Controller is composed of micro-processor, which is the core in the controller, and can precisely detect 2-way 3-phase power, making correct judgment for abnormal power statuses (over voltage, under voltage, loss of phase, over frequency, under frequency) and outputting free voltage control signals. After overall consideration about its bypass switch application, it can be used directly on single and dual bypass switches, and manual or remote control switches. It is with compact structure, advanced circuit, simple wiring, and high reliability, and can be widely used in electrics, telecommunications, petroleum, coal, metallurgy, railway, municipal administration, intelligent building fields, electric installations, servicer power supply and debug system.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nSystem type can set as: S1 Mains S2 Mains, S1 Mains S2 Gen, S1 Gen S2 Mains, S1 Gen S2 Gen;\u003cbr\u003e\n\u003cbr\u003e\n4.3 inchs solid color 240x128 pixel LCD display with white backlit, multilingual interface (including English, Simplified Chinese and other languages), push-button operation;\u003cbr\u003e\n\u003cbr\u003e\nCollect and display voltage, frequency and phase sequence of 2-way 3-phase;\u003cbr\u003e\n\u003cbr\u003e\nCollect and display active power, reactive power, apparent power, power factor and current of load;\u003cbr\u003e\n\u003cbr\u003e\nDisplay position of main switch (working, testing, insulated), and position of bypass switch (working, testing, insulated);\u003cbr\u003e\n\u003cbr\u003e\nIndependent S1\/S2 over current warning or trip alarm functions;\u003cbr\u003e\n\u003cbr\u003e\nNEL (Non-essential Load) trip function;\u003cbr\u003e\n\u003cbr\u003e\nDisplay S1\/S2 total kW energy, total kvar energy;\u003cbr\u003e\n\u003cbr\u003e\nDisplay S1\/S2 accumulated close times of main switch and bypass switch;\u003cbr\u003e\n\u003cbr\u003e\nDisplay continuous power supply time at present and last time, and S1\/S2 total power supply time;\u003cbr\u003e\n\u003cbr\u003e\nCan realize synchronous switchover function, and display voltage difference, frequency difference and phase difference of 2 circuits;\u003cbr\u003e\n\u003cbr\u003e\nFor energy-accumulated ATS, it shall close when switch PF(close is prepared well) signal is active;\u003cbr\u003e\n\u003cbr\u003e\nOver\/under voltage, over\/under frequency, over current, loss of phase, inverse phase sequence protection functions;\u003cbr\u003e\n\u003cbr\u003e\nAutomatic\/Manual mode switchover; In manual mode, close or open can be controlled manually;\u003cbr\u003e\n\u003cbr\u003e\nAll parameters can be set on site. Password validation is applied to prevent wrong operations for non-professionals;\u003cbr\u003e\n\u003cbr\u003e\nThe genset can be tested manually on site to achieve start\/stop operation;\u003cbr\u003e\n\u003cbr\u003e\nRe-close function of main switch and bypass switch in auto mode when power outage occurs;\u003cbr\u003e\n\u003cbr\u003e\nApplicable for single bypass, double bypass and alternate dual spare bypass switch;\u003cbr\u003e\n\u003cbr\u003e\nApplicable for bypass switch of manual control and remote control\u003cbr\u003e\n\u003cbr\u003e\n2-way N wire isolated design;\u003cbr\u003e\n\u003cbr\u003e\nReal-time clock (RTC); event log function, which can record 200 items circularly;\u003cbr\u003e\n\u003cbr\u003e\nBlack box record function, which can record 5 events circularly, 60 data of 50s before each event record, and 10s after each event record;\u003cbr\u003e\n\u003cbr\u003e\nScheduled routing start \u0026amp; scheduled not start function for the genset, which can be set as start once a day\/week\/month; and running with load or not;\u003cbr\u003e\n\u003cbr\u003e\nCan control two generators to work in the mode of circular running, master running and balanced running;\u003cbr\u003e\n\u003cbr\u003e\nWide DC power supply range, which allows the controller to bear instantaneous 80V DC current input;\u003cbr\u003e\n\u003cbr\u003e\nLarge terminal space allows the controller to bear maximum 625V AC voltage input;\u003cbr\u003e\n\u003cbr\u003e\nDual isolated RS485 communication interface, having the functions of \"remote control, remote measuring, remote communication, remote regulating\" by the ModBus-RTU communication protocol, which can remotely start\/stop the genset and control the breaker to close or open;\u003cbr\u003e\n\u003cbr\u003e\nSuitable for multiples of AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire);\u003cbr\u003e\n\u003cbr\u003e\nModular design, antiflaming ABS plastic shell, pluggable terminals, built-in mounting?compact structure and easy installation.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nTechnical Parameters\u003cbr\u003e\nDisplay LCD(240*128)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nVolt Freq Protection ?\u003cbr\u003e\nCurrent and Power Display ?\u003cbr\u003e\nOver Current Warn ?\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\u003cbr\u003e\nRTC(Real Time Clock) ?\u003cbr\u003e\nScheduled Start Genset ?\u003cbr\u003e\nSync Transfer ?\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 260*180*54\u003cbr\u003e\nPanel Cutout(mm) 242*161\u003cbr\u003e\nOperating Temp. (-25~+70)?\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42103049027755,"sku":"HAT880","price":821.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/a28866a9-9a26-5fe8-b4de-02b6d2930259.png?v=1661857851"},{"product_id":"smartgen-hat820s-dual-power-ats-controller","title":"SmartGen HAT820S Dual power ATS controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(240*128)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 11\u003cbr\u003e\nProgrammable Output 12\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nVolt Freq Protection ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface USB\/RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ?\u003cbr\u003e\nSync Transfer ●\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 260*180*54\u003cbr\u003e\nPanel Cutout(mm) 242*161\u003cbr\u003e\nOperating Temp. (-25~+70)●\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT820 series dual power ATS controller is an intelligent dual-power switchover module with configurable function, automatic measurement, LCD display, and digital communication. It combines digitization, intelligence and networking together. Measurement and control process can be conducted automatically, which reduces artificial operating mistakes, so that it is the ideal option for dual-power switchover products.\u003cbr\u003e\n\u003cbr\u003e\nHAT820 series dual power ATS controller is composed by the powerful microprocessor in the core, which can precisely measure the voltages (2-way 3-phase) and make accurate decision for abnormal voltages (overvoltage, undervoltage, overfrequency, underfrequency, phase loss, reverse phase sequence), and putout power-off control digital signal. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building and etc.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set as Mains-Power Generation, Power Generation-Mains, Mains-Mains, Power Generation-Power Generation;\u003cbr\u003e\n\u003cbr\u003e\n4.3-inch large LCD Display of single color, 240x128 pixel with white backlight, multiple language display (Simplified Chinese, Engligh, and Other), default language for Other is Traditional Chinese, and tuch-button operation;\u003cbr\u003e\n\u003cbr\u003e\nCollect and display 2-way 3-phase voltages, frequency and phase sequence;\u003cbr\u003e\n\u003cbr\u003e\nCollect and display loading active power, reactive power, apparent power, power factor and current;\u003cbr\u003e\n\u003cbr\u003e\nIndependent over current warning and trip alarm functions for S1 and S2;\u003cbr\u003e\n\u003cbr\u003e\nNEL trip function;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of accumulated active power, accumulated reactive power, accumulated close times, accumulated automatic transfer times, and mains outage transfer times for S1 and S2;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of continuous power supply time, accumulated power supply time for S1 and S2, accumulated automatic transfer running time;\u003cbr\u003e\n\u003cbr\u003e\nFor energy-accumulated switch, it has function of breaker close when switch PF (close is well prepared) signal is active;\u003cbr\u003e\n\u003cbr\u003e\nFunctions of over voltage, under voltage, over frequency, under frequency, over current, loss of phase, and inverse phase sequence;\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual status switchover is set, and breaker close\/open can be controlled manually in manual mode;\u003cbr\u003e\n\u003cbr\u003e\nAll parameters can be configured on site, and it applies password verification, which can prevent non-professional mistake operation;\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done on site manually to do start\/stop operation of genset;\u003cbr\u003e\n\u003cbr\u003e\nFunction of breaker re-close function;\u003cbr\u003e\n\u003cbr\u003e\nClose output can be pulse or continuous output;\u003cbr\u003e\n\u003cbr\u003e\n2-way N wire isolated design;\u003cbr\u003e\n\u003cbr\u003e\nReal time clock display, event log function with recording cyclical 200 data;\u003cbr\u003e\n\u003cbr\u003e\nScheduled detecting start\/scheduled not start function for genset; it can be set to run for once, each month, or each week, and running with loading or not can also be set;\u003cbr\u003e\n\u003cbr\u003e\nIt can control two gensets, realizing cyclical running, master running, and balanced time running;\u003cbr\u003e\n\u003cbr\u003e\nWide range of DC power supply, which can bear max. 80V DC input transiently;\u003cbr\u003e\n\u003cbr\u003e\nAC power supply can be phase voltage (L, N), or wire voltage (L, L) with supply range: (90~576)V;\u003cbr\u003e\n\u003cbr\u003e\nLarge space between AC input wire terminals, which can bear 625V voltage input;\u003cbr\u003e\n\u003cbr\u003e\nLoading end is live or not can be detected;\u003cbr\u003e\n\u003cbr\u003e\n2 ways of RS485 isolated communication ports are set, which has remote control, remote communication, remote measurement, and remote regulation functions by ModBus-RTU communication protocol; it can also remote control genset start, stop, breaker close and open functions;\u003cbr\u003e\n\u003cbr\u003e\nSuitable for multiple AC system types (3-phase 4-line, 3-phase 3-line, 1-phase 2-line, 2-phase 3-line methods);\u003cbr\u003e\n\u003cbr\u003e\nModular structure design, flame retarding ABS shell, pluggable connecting terminal, and embedded installation method, with compact structure and convenient installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42103049322667,"sku":"HAT820S","price":786.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/7fcf0188-3539-5205-9345-3c02ddfbd5f8.png?v=1661857901"},{"product_id":"smartgen-hat820-dual-power-ats-controller","title":"SmartGen HAT820 Dual power ATS controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(240*128)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 11\u003cbr\u003e\nProgrammable Output 12\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nVolt Freq Protection ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface USB\/RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 260*180*54\u003cbr\u003e\nPanel Cutout(mm) 242*161\u003cbr\u003e\nOperating Temp. (-25~+70)●\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT820 series dual power ATS controller is an intelligent dual-power switchover module with configurable function, automatic measurement, LCD display, and digital communication. It combines digitization, intelligence and networking together. Measurement and control process can be conducted automatically, which reduces artificial operating mistakes, so that it is the ideal option for dual-power switchover products.\u003cbr\u003e\n\u003cbr\u003e\nHAT820 series dual power ATS controller is composed by the powerful microprocessor in the core, which can precisely measure the voltages (2-way 3-phase) and make accurate decision for abnormal voltages (overvoltage, undervoltage, overfrequency, underfrequency, phase loss, reverse phase sequence), and putout power-off control digital signal. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building and etc.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set as Mains-Power Generation, Power Generation-Mains, Mains-Mains, Power Generation-Power Generation;\u003cbr\u003e\n\u003cbr\u003e\n4.3-inch large LCD Display of single color, 240x128 pixel with white backlight, multiple language display (Simplified Chinese, Engligh, and Other), default language for Other is Traditional Chinese, and tuch-button operation;\u003cbr\u003e\n\u003cbr\u003e\nCollect and display 2-way 3-phase voltages, frequency and phase sequence;\u003cbr\u003e\n\u003cbr\u003e\nCollect and display loading active power, reactive power, apparent power, power factor and current;\u003cbr\u003e\n\u003cbr\u003e\nIndependent over current warning and trip alarm functions for S1 and S2;\u003cbr\u003e\n\u003cbr\u003e\nNEL trip function;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of accumulated active power, accumulated reactive power, accumulated close times, accumulated automatic transfer times, and mains outage transfer times for S1 and S2;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of continuous power supply time, accumulated power supply time for S1 and S2, accumulated automatic transfer running time;\u003cbr\u003e\n\u003cbr\u003e\nFor energy-accumulated switch, it has function of breaker close when switch PF (close is well prepared) signal is active;\u003cbr\u003e\n\u003cbr\u003e\nFunctions of over voltage, under voltage, over frequency, under frequency, over current, loss of phase, and inverse phase sequence;\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual status switchover is set, and breaker close\/open can be controlled manually in manual mode;\u003cbr\u003e\n\u003cbr\u003e\nAll parameters can be configured on site, and it applies password verification, which can prevent non-professional mistake operation;\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done on site manually to do start\/stop operation of genset;\u003cbr\u003e\n\u003cbr\u003e\nFunction of breaker re-close function;\u003cbr\u003e\n\u003cbr\u003e\nClose output can be pulse or continuous output;\u003cbr\u003e\n\u003cbr\u003e\n2-way N wire isolated design;\u003cbr\u003e\n\u003cbr\u003e\nReal time clock display, event log function with recording cyclical 200 data;\u003cbr\u003e\n\u003cbr\u003e\nScheduled detecting start\/scheduled not start function for genset; it can be set to run for once, each month, or each week, and running with loading or not can also be set;\u003cbr\u003e\n\u003cbr\u003e\nIt can control two gensets, realizing cyclical running, master running, and balanced time running;\u003cbr\u003e\n\u003cbr\u003e\nWide range of DC power supply, which can bear max. 80V DC input transiently;\u003cbr\u003e\n\u003cbr\u003e\nAC power supply can be phase voltage (L, N), or wire voltage (L, L) with supply range: (90~576)V;\u003cbr\u003e\n\u003cbr\u003e\nLarge space between AC input wire terminals, which can bear 625V voltage input;\u003cbr\u003e\n\u003cbr\u003e\nLoading end is live or not can be detected;\u003cbr\u003e\n\u003cbr\u003e\n2 ways of RS485 isolated communication ports are set, which has remote control, remote communication, remote measurement, and remote regulation functions by ModBus-RTU communication protocol; it can also remote control genset start, stop, breaker close and open functions;\u003cbr\u003e\n\u003cbr\u003e\nSuitable for multiple AC system types (3-phase 4-line, 3-phase 3-line, 1-phase 2-line, 2-phase 3-line methods);\u003cbr\u003e\n\u003cbr\u003e\nModular structure design, flame retarding ABS shell, pluggable connecting terminal, and embedded installation method, with compact structure and convenient installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42103281647787,"sku":"HAT820","price":612.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/1a0c9c6d-6cca-50ea-9d5b-264059a2ffa8.png?v=1661864784"},{"product_id":"smartgen-hat600ps-dual-power-synchronous-ats-controller","title":"SmartGen HAT600PS Dual Power Synchronous ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 4\u003cbr\u003e\nProgrammable Output 6\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nOver Current Warn ●\u003cbr\u003e\nVolt Freq Protection 50\/60Hz\u003cbr\u003e\nCurrent and Power Display ●\u003cbr\u003e\nMonitor Interface RS485\/ETHERNET\u003cbr\u003e\nProgrammable Interface RS485\/USB\/EHTERNET\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSync Transfer ●\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 198*154*54\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)●\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT600P Series Dual Power Synchronous ATS Controller is an intelligent dual-supply synchronous transfer module integrating programmable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking. Automatic measurement and control reduces incorrect operation. It is an ideal option for dual power transfer.\u003cbr\u003e\n\u003cbr\u003e\nHAT600P Series Dual Power Synchronous ATS Controller is made by microprocessor as its core, which can accurately detect 2-way-3-phase voltage, make accurate judgment and output passive control switch for occurred abnormal voltages (overvoltage, undervoltage, loss of phase, overfrequency and underfrequency). This controller is applicable for Mains-Mains, Mains-Gen, Gen-Gen power supply system and can be used for transfer switch of PC class, CB class, and CC class after full consideration on various ATS (Automatic Transfer System) applications; Meanwhile it realizes synchronous transfer of two power supplies. It have compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nLCD 132x64 pixel with backlight, multiple language display (Simplified Chinese, English, Other), push button operation.\u003cbr\u003e\n\u003cbr\u003e\nLED lamp can directly display current ATS close\/open status, power status and whether load is power on.\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set to: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#).\u003cbr\u003e\n\u003cbr\u003e\nS1 master, or S2 master can be set; Auto Transfer Auto Recover and Auto Transfer Non Recover are fitted for master power.\u003cbr\u003e\n\u003cbr\u003e\nMeasure and display 2-way 3 phase Voltage, Frequency, and Phase Sequence Status.\u003cbr\u003e\n\u003cbr\u003e\nCollect and display load active power, reactive power, apparent power, power factor and current.\u003cbr\u003e\n\u003cbr\u003e\nIndependent overcurrent warning or trip alarm functions for S1\/S2.\u003cbr\u003e\n\u003cbr\u003e\nNEL trip function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nLoad voltage monitoring function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nDisplay of accumulated active power, accumulated reactive power, accumulated close times is fitted.\u003cbr\u003e\n\u003cbr\u003e\nEach phase voltage of S1\/S2, wave distortion rate of load current and 3-21 odd times harmonic percentage can be measured.\u003cbr\u003e\n\u003cbr\u003e\nDisplay of current power supply time and S1\/S2 continuous power supply time is available.\u003cbr\u003e\n\u003cbr\u003e\nAutomatic and manual synchronous transfer function is applicable, and the difference of voltage, frequency and phase of two circuits can be displayed.\u003cbr\u003e\n\u003cbr\u003e\nFor energy saving switch, users can wait for and close the switch until PF (close is ready) signal is active.\u003cbr\u003e\n\u003cbr\u003e\nOvervoltage, undervoltage, overfrequency, underfrequency, loss of phase, reverse phase sequence functions are fitted.\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual transfer is fitted, so that breaker can be forced to close or open in manual mode.\u003cbr\u003e\n\u003cbr\u003e\nAll parameters can be configured on site; password is used to verify in case of non professionals wrong operation.\u003cbr\u003e\n\u003cbr\u003e\nCustom start screen function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done manually on site to conduct genset start\/stop operations.\u003cbr\u003e\n\u003cbr\u003e\nSwitch re-close and breakout re-close functions are fitted.\u003cbr\u003e\n\u003cbr\u003e\nClose output can be set to pulse or continuous output.\u003cbr\u003e\n\u003cbr\u003e\nApplicable for switches of PC class two segments, PC class three segments, CB class and CC class.\u003cbr\u003e\n\u003cbr\u003e\n2 circuit N wire isolated design.\u003cbr\u003e\n\u003cbr\u003e\nReal time clock display, and event log function, which can record 200 data circularly.\u003cbr\u003e\n\u003cbr\u003e\nBlack box function, which can record 5 sets of events of ATS transfer, and 60 detailed data of 50s before one set occurs and 10s after the event.\u003cbr\u003e\n\u003cbr\u003e\nScheduled run\/not run function for genset, run for once, run monthly or weekly, and run on load or unload can also be set.\u003cbr\u003e\n\u003cbr\u003e\nTwo gensets can be controlled and cycle run, master run, and balanced time run can be realized.\u003cbr\u003e\n\u003cbr\u003e\nWide DC supply range, maximum 80V DC input for transient.\u003cbr\u003e\n\u003cbr\u003e\nWide wire terminal space of AC input, maximum 625V voltage input.\u003cbr\u003e\n\u003cbr\u003e\nUSB port, provides convenience for on-site debugging, and parameter or software upgrade.\u003cbr\u003e\n\u003cbr\u003e\nRS485 isolated communication port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus-RTU; it can remote control genset start\/stop, ATS close and open.\u003cbr\u003e\n\u003cbr\u003e\nETHERNET port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus TCP\/IP; it can remote control genset start\/stop, ATS close and open.\u003cbr\u003e\n\u003cbr\u003e\nSuitable for multiple AC system types (3Ph 4W, 3Ph 3W, Single Phase 2W, 2 Ph 3W).\u003cbr\u003e\n\u003cbr\u003e\nMaster and backup power supply can be set; ATS can normally work if one circuit is normal.\u003cbr\u003e\n\u003cbr\u003e\nController uses metal clips to fix.\u003cbr\u003e\n\u003cbr\u003e\nModular structure design, anti-flammable ABS shell, pluggable wire terminal, built-in installation method; structure is compact and installation is easy.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42103286956203,"sku":"HAT600PS","price":611.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/db7b9a2d-cf23-5aa4-a87b-0ec024ae3e52.png?v=1661864945"},{"product_id":"smartgen-hat600rbi-dual-power-ats-controller","title":"SmartGen HAT600RBI Dual Power ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\n\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 4\u003cbr\u003e\nProgrammable Output 6\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface RS485\/EHTERNET\u003cbr\u003e\nProgrammable Interface RS485\/USB\/EHTERNET\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nDC Supply DC(8 35)V\u003cbr\u003e\nCase Dimensions(mm) 198*154*54\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)●\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT600R Series Dual Power ATS Controller is an intelligent dual-supply synchronous transfer module integrating programmable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking. Automatic measurement and control reduce the incorrect operation. It is an ideal option for dual power transfer.\u003cbr\u003e\n\u003cbr\u003e\nHAT600P Series Dual Power ATS Controller is made by microprocessor as its core, which can accurately detect 2-way-3-phase voltage, make accurate and quick judgment and output passive control switch for occurred abnormal voltages (over\/under voltage, loss of phase, over\/under frequency). This controller is applicable for Mains-Mains, Mains-Gen, Gen-Gen power supply system and can be used for transfer switch of PC class, CB class, and CC class after full consideration on various ATS (Automatic Transfer System) applications; Meanwhile it realizes synchronous parallel transfer or in-phase transfer of two power supplies. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nWith the function of quick transfer, the automatic transfer response time is as low as 50ms, matching with the fast ATS switch, which can achieve the transfer time less than 100ms;\u003cbr\u003e\n\u003cbr\u003e\nIn-phase transfer function;\u003cbr\u003e\n\u003cbr\u003e\nSynchronous parallel transfer function (HAT600RS only), display the voltage difference, frequency difference and phase difference of two-way power supply;\u003cbr\u003e\n\u003cbr\u003e\nLCD 132x64 pixel with backlight, multiple language display (Simplified Chinese, English, Other), push button operation;\u003cbr\u003e\n\u003cbr\u003e\nLED lamp can directly display current ATS close\/open status, power status and whether load is power on;\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set to: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#);\u003cbr\u003e\n\u003cbr\u003e\nS1 master, or S2 master can be set; Auto Transfer Auto Restore and Auto Transfer Non Restore are fitted for master power;\u003cbr\u003e\n\u003cbr\u003e\nMeasure and display 2-way 3 phase Voltage, Frequency, and Phase Sequence Status;\u003cbr\u003e\n\u003cbr\u003e\nCollect and display load active power, reactive power, apparent power, power factor and current;\u003cbr\u003e\n\u003cbr\u003e\nIndependent overcurrent warning or trip alarm functions for S1\/S2;\u003cbr\u003e\n\u003cbr\u003e\nNEL trip function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nLoad voltage monitoring function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of accumulated active power, accumulated reactive power, accumulated close times is fitted;\u003cbr\u003e\n\u003cbr\u003e\nEach phase voltage of S1\/S2, wave distortion rate of load current and 3-21 odd times harmonic percentage can be measured;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of current power supply time and S1\/S2 continuous power supply time is available;\u003cbr\u003e\n\u003cbr\u003e\nFor energy saving switch, users can wait for and close the switch until PF (close is ready) signal is active;\u003cbr\u003e\n\u003cbr\u003e\nOver\/under voltage, over\/under frequency, loss of phase, reverse phase sequence monitoring functions are fitted;\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual transfer is fitted, so that breaker can be forced to close or open in manual mode;\u003cbr\u003e\n\u003cbr\u003e\nAll parameters can be configured on site; password is used to verify in case of non professionals wrong operation;\u003cbr\u003e\n\u003cbr\u003e\nCustom start screen function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done manually on site to conduct genset start\/stop operations;\u003cbr\u003e\n\u003cbr\u003e\nSwitch re-close and breakout re-close functions are fitted;\u003cbr\u003e\n\u003cbr\u003e\nClose output can be set to pulse or continuous output;\u003cbr\u003e\n\u003cbr\u003e\nApplicable for switches of PC class two segments, PC class three segments, CB class and CC class;\u003cbr\u003e\n\u003cbr\u003e\n2 circuit N wire isolated design;\u003cbr\u003e\n\u003cbr\u003e\nReal time clock display, and event log function, which can record 200 data circularly;\u003cbr\u003e\n\u003cbr\u003e\nBlack box function, which can record 5 sets of events of ATS transfer, and 60 detailed data of 50s before one set occurs and 10s after the event;\u003cbr\u003e\n\u003cbr\u003e\nScheduled run\/not run function for genset, run for once, run monthly or weekly, and run on load or unload can also be set;\u003cbr\u003e\n\u003cbr\u003e\nTwo gensets can be controlled and cycle run, master run, and balanced time run can be realized.\u003cbr\u003e\n\u003cbr\u003e\nWide DC supply range, maximum 80V DC input for transient;\u003cbr\u003e\n\u003cbr\u003e\nWide wire terminal space of AC input, maximum 625V voltage input;\u003cbr\u003e\n\u003cbr\u003e\nUSB port, provides convenience for on-site debugging, and parameter or software upgrade;\u003cbr\u003e\n\u003cbr\u003e\nRS485 isolated communication port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus-RTU; it can remote control genset start\/stop, ATS close and open;\u003cbr\u003e\n\u003cbr\u003e\nETHERNET port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus TCP\/IP; it can remote control genset start\/stop, ATS close and open;\u003cbr\u003e\n\u003cbr\u003e\nSuitable for multiple AC system types (3Ph 4W, 3Ph 3W, Single Phase 2W, 2 Ph 3W);\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42103314317483,"sku":"HAT600RBI","price":506.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/d81896ab-56e4-5e6d-b921-6fc4e756c6a4.png?v=1661865760"},{"product_id":"smartgen-hat600ri-dual-power-ats-controller","title":"SmartGen HAT600RI Dual Power ATS Controller","description":"\u003cp\u003eTechnical Parameters\u003cbr\u003e\n\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 4\u003cbr\u003e\nProgrammable Output 6\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\/USB\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 198*154*54\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT600R Series Dual Power ATS Controller is an intelligent dual-supply synchronous transfer module integrating programmable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking. Automatic measurement and control reduce the incorrect operation. It is an ideal option for dual power transfer.\u003cbr\u003e\n\u003cbr\u003e\nHAT600P Series Dual Power ATS Controller is made by microprocessor as its core, which can accurately detect 2-way-3-phase voltage, make accurate and quick judgment and output passive control switch for occurred abnormal voltages (over\/under voltage, loss of phase, over\/under frequency). This controller is applicable for Mains-Mains, Mains-Gen, Gen-Gen power supply system and can be used for transfer switch of PC class, CB class, and CC class after full consideration on various ATS (Automatic Transfer System) applications; Meanwhile it realizes synchronous parallel transfer or in-phase transfer of two power supplies. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nWith the function of quick transfer, the automatic transfer response time is as low as 50ms, matching with the fast ATS switch, which can achieve the transfer time less than 100ms;\u003cbr\u003e\n\u003cbr\u003e\nIn-phase transfer function;\u003cbr\u003e\n\u003cbr\u003e\nSynchronous parallel transfer function (HAT600RS only), display the voltage difference, frequency difference and phase difference of two-way power supply;\u003cbr\u003e\n\u003cbr\u003e\nLCD 132x64 pixel with backlight, multiple language display (Simplified Chinese, English, Other), push button operation;\u003cbr\u003e\n\u003cbr\u003e\nLED lamp can directly display current ATS close\/open status, power status and whether load is power on;\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set to: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#);\u003cbr\u003e\n\u003cbr\u003e\nS1 master, or S2 master can be set; Auto Transfer Auto Restore and Auto Transfer Non Restore are fitted for master power;\u003cbr\u003e\n\u003cbr\u003e\nMeasure and display 2-way 3 phase Voltage, Frequency, and Phase Sequence Status;\u003cbr\u003e\n\u003cbr\u003e\nCollect and display load active power, reactive power, apparent power, power factor and current;\u003cbr\u003e\n\u003cbr\u003e\nIndependent overcurrent warning or trip alarm functions for S1\/S2;\u003cbr\u003e\n\u003cbr\u003e\nNEL trip function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nLoad voltage monitoring function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of accumulated active power, accumulated reactive power, accumulated close times is fitted;\u003cbr\u003e\n\u003cbr\u003e\nEach phase voltage of S1\/S2, wave distortion rate of load current and 3-21 odd times harmonic percentage can be measured;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of current power supply time and S1\/S2 continuous power supply time is available;\u003cbr\u003e\n\u003cbr\u003e\nFor energy saving switch, users can wait for and close the switch until PF (close is ready) signal is active;\u003cbr\u003e\n\u003cbr\u003e\nOver\/under voltage, over\/under frequency, loss of phase, reverse phase sequence monitoring functions are fitted;\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual transfer is fitted, so that breaker can be forced to close or open in manual mode;\u003cbr\u003e\n\u003cbr\u003e\nAll parameters can be configured on site; password is used to verify in case of non professionals wrong operation;\u003cbr\u003e\n\u003cbr\u003e\nCustom start screen function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done manually on site to conduct genset start\/stop operations;\u003cbr\u003e\n\u003cbr\u003e\nSwitch re-close and breakout re-close functions are fitted;\u003cbr\u003e\n\u003cbr\u003e\nClose output can be set to pulse or continuous output;\u003cbr\u003e\n\u003cbr\u003e\nApplicable for switches of PC class two segments, PC class three segments, CB class and CC class;\u003cbr\u003e\n\u003cbr\u003e\n2 circuit N wire isolated design;\u003cbr\u003e\n\u003cbr\u003e\nReal time clock display, and event log function, which can record 200 data circularly;\u003cbr\u003e\n\u003cbr\u003e\nBlack box function, which can record 5 sets of events of ATS transfer, and 60 detailed data of 50s before one set occurs and 10s after the event;\u003cbr\u003e\n\u003cbr\u003e\nScheduled run\/not run function for genset, run for once, run monthly or weekly, and run on load or unload can also be set;\u003cbr\u003e\n\u003cbr\u003e\nTwo gensets can be controlled and cycle run, master run, and balanced time run can be realized.\u003cbr\u003e\n\u003cbr\u003e\nWide DC supply range, maximum 80V DC input for transient;\u003cbr\u003e\n\u003cbr\u003e\nWide wire terminal space of AC input, maximum 625V voltage input;\u003cbr\u003e\n\u003cbr\u003e\nUSB port, provides convenience for on-site debugging, and parameter or software upgrade;\u003cbr\u003e\n\u003cbr\u003e\nRS485 isolated communication port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus-RTU; it can remote control genset start\/stop, ATS close and open;\u003cbr\u003e\n\u003cbr\u003e\nETHERNET port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus TCP\/IP; it can remote control genset start\/stop, ATS close and open;\u003cbr\u003e\n\u003cbr\u003e\nSuitable for multiple AC system types (3Ph 4W, 3Ph 3W, Single Phase 2W, 2 Ph 3W);\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42103405215915,"sku":"HAT600RI","price":481.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/8101fe03-a5e2-5428-b3d2-ed6636294625.png?v=1661869185"},{"product_id":"smartgen-hat600pbi-dual-power-synchronous-ats-controller","title":"SmartGen HAT600PBI Dual Power Synchronous ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 4\u003cbr\u003e\nProgrammable Output 6\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nCurrent and Power Display ●\u003cbr\u003e\nOver Current Warn ●\u003cbr\u003e\nVolt Freq Protection 50\/60Hz\u003cbr\u003e\nMonitor Interface RS485\/ETHERNET\u003cbr\u003e\nProgrammable Interface RS485\/USB\/EHTERNET\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 198*154*54\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT600P Series Dual Power Synchronous ATS Controller is an intelligent dual-supply synchronous transfer module integrating programmable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking. Automatic measurement and control reduces incorrect operation. It is an ideal option for dual power transfer.\u003cbr\u003e\n\u003cbr\u003e\nHAT600P Series Dual Power Synchronous ATS Controller is made by microprocessor as its core, which can accurately detect 2-way-3-phase voltage, make accurate judgment and output passive control switch for occurred abnormal voltages (overvoltage, undervoltage, loss of phase, overfrequency and underfrequency). This controller is applicable for Mains-Mains, Mains-Gen, Gen-Gen power supply system and can be used for transfer switch of PC class, CB class, and CC class after full consideration on various ATS (Automatic Transfer System) applications; Meanwhile it realizes synchronous transfer of two power supplies. It have compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\nMODEL COMPARISON\u003cbr\u003e\n\u003cbr\u003e\nItem HAT600P HAT600PB HAT600PI HAT600PBI HAT600PS\u003cbr\u003e\nDC Supply ? ? ? ? ?\u003cbr\u003e\nAC Supply(LN90V~300V)\u003cbr\u003e\n?\u003cbr\u003e\n? ?\u003cbr\u003e\nCurrent Monitor\u003cbr\u003e\n\u003cbr\u003e\n? ? ?\u003cbr\u003e\nSynch. Transfer\u003cbr\u003e\n\u003cbr\u003e\n?\u003cbr\u003e\nInput Port No.(Fixed+Flexible) 2+4 2+4 2+4 2+4 2+4\u003cbr\u003e\nOutput Port No.(Fixed+Flexible) 2+6 2+6 2+6 2+6 2+6\u003cbr\u003e\nGenset Control ? ? ? ? ?\u003cbr\u003e\nRS485 ? ? ? ? ?\u003cbr\u003e\nUSB ? ? ? ? ?\u003cbr\u003e\nEHTERNET\u003cbr\u003e\n\u003cbr\u003e\n? ?\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nLCD 132x64 pixel with backlight, multiple language display (Simplified Chinese, English, Other), push button operation.\u003cbr\u003e\n\u003cbr\u003e\nLED lamp can directly display current ATS close\/open status, power status and whether load is power on.\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set to: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#).\u003cbr\u003e\n\u003cbr\u003e\nS1 master, or S2 master can be set; Auto Transfer Auto Recover and Auto Transfer Non Recover are fitted for master power.\u003cbr\u003e\n\u003cbr\u003e\nMeasure and display 2-way 3 phase Voltage, Frequency, and Phase Sequence Status.\u003cbr\u003e\n\u003cbr\u003e\nCollect and display load active power, reactive power, apparent power, power factor and current.\u003cbr\u003e\n\u003cbr\u003e\nIndependent overcurrent warning or trip alarm functions for S1\/S2.\u003cbr\u003e\n\u003cbr\u003e\nNEL trip function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nLoad voltage monitoring function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nDisplay of accumulated active power, accumulated reactive power, accumulated close times is fitted.\u003cbr\u003e\n\u003cbr\u003e\nEach phase voltage of S1\/S2, wave distortion rate of load current and 3-21 odd times harmonic percentage can be measured.\u003cbr\u003e\n\u003cbr\u003e\nDisplay of current power supply time and S1\/S2 continuous power supply time is available.\u003cbr\u003e\n\u003cbr\u003e\nAutomatic and manual synchronous transfer function is applicable, and the difference of voltage, frequency and phase of two circuits can be displayed.\u003cbr\u003e\n\u003cbr\u003e\nFor energy saving switch, users can wait for and close the switch until PF (close is ready) signal is active.\u003cbr\u003e\n\u003cbr\u003e\nOvervoltage, undervoltage, overfrequency, underfrequency, loss of phase, reverse phase sequence functions are fitted.\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual transfer is fitted, so that breaker can be forced to close or open in manual mode.\u003cbr\u003e\n\u003cbr\u003e\nAll parameters can be configured on site; password is used to verify in case of non professionals wrong operation.\u003cbr\u003e\n\u003cbr\u003e\nCustom start screen function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done manually on site to conduct genset start\/stop operations.\u003cbr\u003e\n\u003cbr\u003e\nSwitch re-close and breakout re-close functions are fitted.\u003cbr\u003e\n\u003cbr\u003e\nClose output can be set to pulse or continuous output.\u003cbr\u003e\n\u003cbr\u003e\nApplicable for switches of PC class two segments, PC class three segments, CB class and CC class.\u003cbr\u003e\n\u003cbr\u003e\n2 circuit N wire isolated design.\u003cbr\u003e\n\u003cbr\u003e\nReal time clock display, and event log function, which can record 200 data circularly.\u003cbr\u003e\n\u003cbr\u003e\nBlack box function, which can record 5 sets of events of ATS transfer, and 60 detailed data of 50s before one set occurs and 10s after the event.\u003cbr\u003e\n\u003cbr\u003e\nScheduled run\/not run function for genset, run for once, run monthly or weekly, and run on load or unload can also be set.\u003cbr\u003e\n\u003cbr\u003e\nTwo gensets can be controlled and cycle run, master run, and balanced time run can be realized.\u003cbr\u003e\n\u003cbr\u003e\nWide DC supply range, maximum 80V DC input for transient.\u003cbr\u003e\n\u003cbr\u003e\nWide wire terminal space of AC input, maximum 625V voltage input.\u003cbr\u003e\n\u003cbr\u003e\nUSB port, provides convenience for on-site debugging, and parameter or software upgrade.\u003cbr\u003e\n\u003cbr\u003e\nRS485 isolated communication port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus-RTU; it can remote control genset start\/stop, ATS close and open.\u003cbr\u003e\n\u003cbr\u003e\nETHERNET port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus TCP\/IP; it can remote control genset start\/stop, ATS close and open.\u003cbr\u003e\n\u003cbr\u003e\nSuitable for multiple AC system types (3Ph 4W, 3Ph 3W, Single Phase 2W, 2 Ph 3W).\u003cbr\u003e\n\u003cbr\u003e\nMaster and backup power supply can be set; ATS can normally work if one circuit is normal.\u003cbr\u003e\n\u003cbr\u003e\nController uses metal clips to fix.\u003cbr\u003e\n\u003cbr\u003e\nModular structure design, anti-flammable ABS shell, pluggable wire terminal, built-in installation method; structure is compact and installation is easy.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42103407116459,"sku":"HAT600PBI","price":436.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/b03fd1f9-aaf3-56f0-9542-19e9ae3fd21f.png?v=1661869232"},{"product_id":"smartgen-hat600nbi-ats-controller","title":"SmartGen HAT600NBI ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(128*64)\u003cbr\u003e\nLanguage Chinese\/English\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nkW Detecting \u0026amp; Display ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface LINK\/RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSwitch Over Priority ●\u003cbr\u003e\nApplicable Switch Type All types\u003cbr\u003e\nDC Supply DC(8?35)V\/AC 220V\u003cbr\u003e\nCase Dimensions(mm) 209*153*55(L*W*H)\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT600N series ATS controller is intelligent dual-supply module with programmable function, automatic measurement, LCD display, and digital communication. It combines digital intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003cbr\u003e\n\u003cbr\u003e\nHAT600N series ATS controller is made of microprocessor as its core, can accurately detect extended-spectrum 2-way-3-phase voltage and also make accurate judgment and output passive control switch under the abnormal voltage (over and under voltage, miss phase and over and under frequency). This controller has full consideration in various application of ATS (automatic transfer system) can be directly used for Intelligent ATS, Contactor ATS, Circuit Break ATS etc. It have compact structure, advanced circuits, simple wiring and high reliability, be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\n1. PERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n1) System type can set for: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#).\u003cbr\u003e\n2) Backlit 128x64 LCD, optional Chinese and English display, push-button operation.\u003cbr\u003e\n3) Measure and display 2-way 3 phase Voltage and Frequency:\u003cbr\u003e\n4) Measure and display active power, apparent power, power factor and 3 phase current;\u003cbr\u003e\n5) Over current alarm;\u003cbr\u003e\n6) Over\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection.\u003cbr\u003e\n7) Automatic\/Manual mode. In manual mode, can force switch to close or open;\u003cbr\u003e\n8) All parameters can be set on site. With Two different passwords which ensures authorized staff operation only.\u003cbr\u003e\n9) During genset testing ATS controller can be set either on On-load or Off-load mode.\u003cbr\u003e\n10) ATS Controller has function of automatic Re-closing.\u003cbr\u003e\n11) Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n12) Applicable for ATS of one neutral position, two neutral position and change over.\u003cbr\u003e\n13) Applicable for 2 isolated neutral line for Generator and Mains.\u003cbr\u003e\n14) Real-time clock (RTC).\u003cbr\u003e\n15) Event log can record 99 items circularly.\u003cbr\u003e\n16) Timely schedule can be set on monthly or weekly basis and trial can be set as with on- load or off -load.\u003cbr\u003e\n17) Can control two generators to work in a cycle, even the genset running time and crank rest time can be set.\u003cbr\u003e\n18) Widely range of DC power supply (8V to 35V). Max.80V DC input can be endured in an instant, or be supplied via HWS560 module (input AC 85V~560V, output DC 12V).\u003cbr\u003e\n19) Wide space between connecting terminals of AC input. Max.625V input voltage.\u003cbr\u003e\n20) With standard isolated RS485 communication interface. With \"remote controlling, remote measuring, remote communication\" function by the ModBus communication protocol.\u003cbr\u003e\n21) Can check the current status of controller (including switch digital input, over Voltage, and under Voltage etc.).\u003cbr\u003e\n22) Suitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003cbr\u003e\n23) Modular design, flame-resisting ABS plastic shell, plug-in terminals and embedded installation. Compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42103407345835,"sku":"HAT600NBI","price":436.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/8b665d6a-4339-5e75-85f2-5bffa26d7926.png?v=1661869279"},{"product_id":"smartgen-hat700i-ats-controller","title":"SmartGen HAT700I ATS controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nkW Detecting \u0026amp; Display ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface LINK\/RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSwitch Over Priority ●\u003cbr\u003e\nApplicable Switch Type PC Two-stage, PC Three-stage, CB and CC switch\u003cbr\u003e\nDC Supply DC(8-35)V\u003cbr\u003e\nCase Dimensions(mm) 197*152*47\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT700 series ATS controller is intelligent dual-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digital, intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003cbr\u003e\n\u003cbr\u003e\nThe powerful Microprocessor contained within the unit allows for precision voltage (2-way-3-phase) measuring and make accurate judgment; in addition, the corresponding digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase and other abnormal condition occurs. This controller has full consideration in various application of ATS (automatic transfer system) and can be directly used for PC ATS, CB ATS, CC ATS etc. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical devices, automatic control and testing system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS:\u003cbr\u003e\n1. System type can set as: S1 (Mains) \u0026amp; S2 (Mains), S1 (Mains) \u0026amp; S2 (Generator), S1 (Generator) \u0026amp; S2 (Mains), S1 (Generator) \u0026amp; S2 (Generator).\u003cbr\u003e\n2. 132x64 LCD with backlight, multilingual interface (including English, Chinese or other languages), push-button operation.\u003cbr\u003e\n3. Collect and display 2-way 3-phase Voltage, Frequency and Phase.\u003cbr\u003e\n4. Collect and display Active Power, Reactive Power, Apparent Power, Power Factor and Current.\u003cbr\u003e\n5. S1\/S2 separated over current warning\/ trip alarm.\u003cbr\u003e\n6. NEL (Non-essential Load) trip function.\u003cbr\u003e\n7. Display S1\/S2 Total kW Energy, Total kvar Energy, Total Close Times.\u003cbr\u003e\n8. Display continuous power supply time and S1\/S2 total power supply time.\u003cbr\u003e\n9. Sync Transfer function; in addition, Voltage Difference, Frequency Difference and Phase Difference can be displayed.\u003cbr\u003e\n10. For Stored-Energy type ATS, its close relay will active after the PF Input is active.\u003cbr\u003e\n11. Over\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection.\u003cbr\u003e\n12. Phase Sequence Transfer function.\u003cbr\u003e\n13. Automatic\/Manual mode. In manual mode, can force the switch to close or open;\u003cbr\u003e\n14. All parameters can be set on site. Passwords authentication ensures authorized staff operation only.\u003cbr\u003e\n15. The genset can be Manual Test on site to achieve start\/stop operation.\u003cbr\u003e\n16. ATS Controller has function of automatic Re-closing.\u003cbr\u003e\n17. Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n18. Applicable for PC Three-stage, PC Two-stage, CB and CC switch.\u003cbr\u003e\n19. Applicable for 2 isolated neutral line.\u003cbr\u003e\n20. Real-time clock (RTC); Event log Function (Event log can record 99 items circularly).\u003cbr\u003e\n21. Scheduled Run \u0026amp; Scheduled Not Run (can be set as start genset once a day\/week\/month whether with load or not).\u003cbr\u003e\n22. Can control two generators to work as Cycle Run mode, Master Run mode and Balance Run mode.\u003cbr\u003e\n23. Widely power supply range DC(8~35)V allows the controller can bear 80V instantaneous current.\u003cbr\u003e\n24. Large terminal space allows the controller can bear maximum 625V input voltage.\u003cbr\u003e\n25. With RS485 isolated communication interface. With \"remote controlling, remote measuring, remote communication, remote regulating\" function by the ModBus communication protocol. Can remote start\/stop the genset and remote control the ATS to close or open.\u003cbr\u003e\n26. Suitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003cbr\u003e\n27. Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting?compact structure with easy installation.\u003cbr\u003e\n.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42103409115307,"sku":"HAT700I","price":418.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/95ea3bfe-3fc0-5f75-8748-3ddaec0de760.png?v=1661869359"},{"product_id":"smartgen-hat600pi-dual-power-synchronous-ats-controller","title":"SmartGen HAT600PI Dual Power Synchronous ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 4\u003cbr\u003e\nProgrammable Output 6\u003cbr\u003e\nOver Current Warn ●\u003cbr\u003e\nCurrent and Power Display ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\/USB\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm 198*154*54\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT600P Series Dual Power Synchronous ATS Controller is an intelligent dual-supply synchronous transfer module integrating programmable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking. Automatic measurement and control reduces incorrect operation. It is an ideal option for dual power transfer.\u003cbr\u003e\n\u003cbr\u003e\nHAT600P Series Dual Power Synchronous ATS Controller is made by microprocessor as its core, which can accurately detect 2-way-3-phase voltage, make accurate judgment and output passive control switch for occurred abnormal voltages (overvoltage, undervoltage, loss of phase, overfrequency and underfrequency). This controller is applicable for Mains-Mains, Mains-Gen, Gen-Gen power supply system and can be used for transfer switch of PC class, CB class, and CC class after full consideration on various ATS (Automatic Transfer System) applications; Meanwhile it realizes synchronous transfer of two power supplies. It have compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\nMODEL COMPARISON\u003cbr\u003e\n\u003cbr\u003e\nItem HAT600P HAT600PB HAT600PI HAT600PBI HAT600PS\u003cbr\u003e\nDC Supply ? ? ? ? ?\u003cbr\u003e\nAC Supply(LN90V~300V)\u003cbr\u003e\n?\u003cbr\u003e\n? ?\u003cbr\u003e\nCurrent Monitor\u003cbr\u003e\n\u003cbr\u003e\n? ? ?\u003cbr\u003e\nSynch. Transfer\u003cbr\u003e\n\u003cbr\u003e\n?\u003cbr\u003e\nInput Port No.(Fixed+Flexible) 2+4 2+4 2+4 2+4 2+4\u003cbr\u003e\nOutput Port No.(Fixed+Flexible) 2+6 2+6 2+6 2+6 2+6\u003cbr\u003e\nGenset Control ? ? ? ? ?\u003cbr\u003e\nRS485 ? ? ? ? ?\u003cbr\u003e\nUSB ? ? ? ? ?\u003cbr\u003e\nEHTERNET\u003cbr\u003e\n\u003cbr\u003e\n? ?\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nLCD 132x64 pixel with backlight, multiple language display (Simplified Chinese, English, Other), push button operation.\u003cbr\u003e\n\u003cbr\u003e\nLED lamp can directly display current ATS close\/open status, power status and whether load is power on.\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set to: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#).\u003cbr\u003e\n\u003cbr\u003e\nS1 master, or S2 master can be set; Auto Transfer Auto Recover and Auto Transfer Non Recover are fitted for master power.\u003cbr\u003e\n\u003cbr\u003e\nMeasure and display 2-way 3 phase Voltage, Frequency, and Phase Sequence Status.\u003cbr\u003e\n\u003cbr\u003e\nCollect and display load active power, reactive power, apparent power, power factor and current.\u003cbr\u003e\n\u003cbr\u003e\nIndependent overcurrent warning or trip alarm functions for S1\/S2.\u003cbr\u003e\n\u003cbr\u003e\nNEL trip function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nLoad voltage monitoring function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nDisplay of accumulated active power, accumulated reactive power, accumulated close times is fitted.\u003cbr\u003e\n\u003cbr\u003e\nEach phase voltage of S1\/S2, wave distortion rate of load current and 3-21 odd times harmonic percentage can be measured.\u003cbr\u003e\n\u003cbr\u003e\nDisplay of current power supply time and S1\/S2 continuous power supply time is available.\u003cbr\u003e\n\u003cbr\u003e\nAutomatic and manual synchronous transfer function is applicable, and the difference of voltage, frequency and phase of two circuits can be displayed.\u003cbr\u003e\n\u003cbr\u003e\nFor energy saving switch, users can wait for and close the switch until PF (close is ready) signal is active.\u003cbr\u003e\n\u003cbr\u003e\nOvervoltage, undervoltage, overfrequency, underfrequency, loss of phase, reverse phase sequence functions are fitted.\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual transfer is fitted, so that breaker can be forced to close or open in manual mode.\u003cbr\u003e\n\u003cbr\u003e\nAll parameters can be configured on site; password is used to verify in case of non professionals wrong operation.\u003cbr\u003e\n\u003cbr\u003e\nCustom start screen function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done manually on site to conduct genset start\/stop operations.\u003cbr\u003e\n\u003cbr\u003e\nSwitch re-close and breakout re-close functions are fitted.\u003cbr\u003e\n\u003cbr\u003e\nClose output can be set to pulse or continuous output.\u003cbr\u003e\n\u003cbr\u003e\nApplicable for switches of PC class two segments, PC class three segments, CB class and CC class.\u003cbr\u003e\n\u003cbr\u003e\n2 circuit N wire isolated design.\u003cbr\u003e\n\u003cbr\u003e\nReal time clock display, and event log function, which can record 200 data circularly.\u003cbr\u003e\n\u003cbr\u003e\nBlack box function, which can record 5 sets of events of ATS transfer, and 60 detailed data of 50s before one set occurs and 10s after the event.\u003cbr\u003e\n\u003cbr\u003e\nScheduled run\/not run function for genset, run for once, run monthly or weekly, and run on load or unload can also be set.\u003cbr\u003e\n\u003cbr\u003e\nTwo gensets can be controlled and cycle run, master run, and balanced time run can be realized.\u003cbr\u003e\n\u003cbr\u003e\nWide DC supply range, maximum 80V DC input for transient.\u003cbr\u003e\n\u003cbr\u003e\nWide wire terminal space of AC input, maximum 625V voltage input.\u003cbr\u003e\n\u003cbr\u003e\nUSB port, provides convenience for on-site debugging, and parameter or software upgrade.\u003cbr\u003e\n\u003cbr\u003e\nRS485 isolated communication port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus-RTU; it can remote control genset start\/stop, ATS close and open.\u003cbr\u003e\n\u003cbr\u003e\nETHERNET port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus TCP\/IP; it can remote control genset start\/stop, ATS close and open.\u003cbr\u003e\n\u003cbr\u003e\nSuitable for multiple AC system types (3Ph 4W, 3Ph 3W, Single Phase 2W, 2 Ph 3W).\u003cbr\u003e\n\u003cbr\u003e\nMaster and backup power supply can be set; ATS can normally work if one circuit is normal.\u003cbr\u003e\n\u003cbr\u003e\nController uses metal clips to fix.\u003cbr\u003e\n\u003cbr\u003e\nModular structure design, anti-flammable ABS shell, pluggable wire terminal, built-in installation method; structure is compact and installation is easy.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42103410950315,"sku":"HAT600PI","price":418.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/f74c9cf8-69ac-5fbb-9fe8-9c6a7d26c175.png?v=1661869406"},{"product_id":"smartgen-hat600ni-ats-controller","title":"SmartGen HAT600NI ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(128*64)\u003cbr\u003e\nLanguage Chinese\/English\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nkW Detecting \u0026amp; Display ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface LINK\/RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSwitch Over Priority ●\u003cbr\u003e\nApplicable Switch Type All types\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 209*153*55(L*W*H)\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT600N series ATS controller is intelligent dual-supply module with programmable function, automatic measurement, LCD display, and digital communication. It combines digital intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003cbr\u003e\n\u003cbr\u003e\nHAT600N series ATS controller is made of microprocessor as its core, can accurately detect extended-spectrum 2-way-3-phase voltage and also make accurate judgment and output passive control switch under the abnormal voltage (over and under voltage, miss phase and over and under frequency). This controller has full consideration in various application of ATS (automatic transfer system) can be directly used for Intelligent ATS, Contactor ATS, Circuit Break ATS etc. It have compact structure, advanced circuits, simple wiring and high reliability, be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\n1. PERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n1) System type can set for: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#).\u003cbr\u003e\n2) Backlit 128x64 LCD, optional Chinese and English display, push-button operation.\u003cbr\u003e\n3) Measure and display 2-way 3 phase Voltage and Frequency:\u003cbr\u003e\n4) Measure and display active power, apparent power, power factor and 3 phase current;\u003cbr\u003e\n5) Over current alarm;\u003cbr\u003e\n6) Over\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection.\u003cbr\u003e\n7) Automatic\/Manual mode. In manual mode, can force switch to close or open;\u003cbr\u003e\n8) All parameters can be set on site. With Two different passwords which ensures authorized staff operation only.\u003cbr\u003e\n9) During genset testing ATS controller can be set either on On-load or Off-load mode.\u003cbr\u003e\n10) ATS Controller has function of automatic Re-closing.\u003cbr\u003e\n11) Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n12) Applicable for ATS of one neutral position, two neutral position and change over.\u003cbr\u003e\n13) Applicable for 2 isolated neutral line for Generator and Mains.\u003cbr\u003e\n14) Real-time clock (RTC).\u003cbr\u003e\n15) Event log can record 99 items circularly.\u003cbr\u003e\n16) Timely schedule can be set on monthly or weekly basis and trial can be set as with on- load or off -load.\u003cbr\u003e\n17) Can control two generators to work in a cycle, even the genset running time and crank rest time can be set.\u003cbr\u003e\n18) Widely range of DC power supply (8V to 35V). Max.80V DC input can be endured in an instant, or be supplied via HWS560 module (input AC 85V~560V, output DC 12V).\u003cbr\u003e\n19) Wide space between connecting terminals of AC input. Max.625V input voltage.\u003cbr\u003e\n20) With standard isolated RS485 communication interface. With \"remote controlling, remote measuring, remote communication\" function by the ModBus communication protocol.\u003cbr\u003e\n21) Can check the current status of controller (including switch digital input, over Voltage, and under Voltage etc.).\u003cbr\u003e\n22) Suitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003cbr\u003e\n23) Modular design, flame-resisting ABS plastic shell, plug-in terminals and embedded installation. Compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42103411507371,"sku":"HAT600NI","price":418.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/df9550e2-2894-5ddc-832d-7eaae294f37b.png?v=1661869468"},{"product_id":"smartgen-hat600rb-dual-power-ats-controller","title":"SmartGen HAT600RB Dual Power ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\n\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 4\u003cbr\u003e\nProgrammable Output 6\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\/USB\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 198*154*54\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT600R Series Dual Power ATS Controller is an intelligent dual-supply synchronous transfer module integrating programmable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking. Automatic measurement and control reduce the incorrect operation. It is an ideal option for dual power transfer.\u003cbr\u003e\n\u003cbr\u003e\nHAT600P Series Dual Power ATS Controller is made by microprocessor as its core, which can accurately detect 2-way-3-phase voltage, make accurate and quick judgment and output passive control switch for occurred abnormal voltages (over\/under voltage, loss of phase, over\/under frequency). This controller is applicable for Mains-Mains, Mains-Gen, Gen-Gen power supply system and can be used for transfer switch of PC class, CB class, and CC class after full consideration on various ATS (Automatic Transfer System) applications; Meanwhile it realizes synchronous parallel transfer or in-phase transfer of two power supplies. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nWith the function of quick transfer, the automatic transfer response time is as low as 50ms, matching with the fast ATS switch, which can achieve the transfer time less than 100ms;\u003cbr\u003e\n\u003cbr\u003e\nIn-phase transfer function;\u003cbr\u003e\n\u003cbr\u003e\nSynchronous parallel transfer function (HAT600RS only), display the voltage difference, frequency difference and phase difference of two-way power supply;\u003cbr\u003e\n\u003cbr\u003e\nLCD 132x64 pixel with backlight, multiple language display (Simplified Chinese, English, Other), push button operation;\u003cbr\u003e\n\u003cbr\u003e\nLED lamp can directly display current ATS close\/open status, power status and whether load is power on;\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set to: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#);\u003cbr\u003e\n\u003cbr\u003e\nS1 master, or S2 master can be set; Auto Transfer Auto Restore and Auto Transfer Non Restore are fitted for master power;\u003cbr\u003e\n\u003cbr\u003e\nMeasure and display 2-way 3 phase Voltage, Frequency, and Phase Sequence Status;\u003cbr\u003e\n\u003cbr\u003e\nCollect and display load active power, reactive power, apparent power, power factor and current;\u003cbr\u003e\n\u003cbr\u003e\nIndependent overcurrent warning or trip alarm functions for S1\/S2;\u003cbr\u003e\n\u003cbr\u003e\nNEL trip function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nLoad voltage monitoring function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of accumulated active power, accumulated reactive power, accumulated close times is fitted;\u003cbr\u003e\n\u003cbr\u003e\nEach phase voltage of S1\/S2, wave distortion rate of load current and 3-21 odd times harmonic percentage can be measured;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of current power supply time and S1\/S2 continuous power supply time is available;\u003cbr\u003e\n\u003cbr\u003e\nFor energy saving switch, users can wait for and close the switch until PF (close is ready) signal is active;\u003cbr\u003e\n\u003cbr\u003e\nOver\/under voltage, over\/under frequency, loss of phase, reverse phase sequence monitoring functions are fitted;\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual transfer is fitted, so that breaker can be forced to close or open in manual mode;\u003cbr\u003e\n\u003cbr\u003e\nAll parameters can be configured on site; password is used to verify in case of non professionals wrong operation;\u003cbr\u003e\n\u003cbr\u003e\nCustom start screen function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done manually on site to conduct genset start\/stop operations;\u003cbr\u003e\n\u003cbr\u003e\nSwitch re-close and breakout re-close functions are fitted;\u003cbr\u003e\n\u003cbr\u003e\nClose output can be set to pulse or continuous output;\u003cbr\u003e\n\u003cbr\u003e\nApplicable for switches of PC class two segments, PC class three segments, CB class and CC class;\u003cbr\u003e\n\u003cbr\u003e\n2 circuit N wire isolated design;\u003cbr\u003e\n\u003cbr\u003e\nReal time clock display, and event log function, which can record 200 data circularly;\u003cbr\u003e\n\u003cbr\u003e\nBlack box function, which can record 5 sets of events of ATS transfer, and 60 detailed data of 50s before one set occurs and 10s after the event;\u003cbr\u003e\n\u003cbr\u003e\nScheduled run\/not run function for genset, run for once, run monthly or weekly, and run on load or unload can also be set;\u003cbr\u003e\n\u003cbr\u003e\nTwo gensets can be controlled and cycle run, master run, and balanced time run can be realized.\u003cbr\u003e\n\u003cbr\u003e\nWide DC supply range, maximum 80V DC input for transient;\u003cbr\u003e\n\u003cbr\u003e\nWide wire terminal space of AC input, maximum 625V voltage input;\u003cbr\u003e\n\u003cbr\u003e\nUSB port, provides convenience for on-site debugging, and parameter or software upgrade;\u003cbr\u003e\n\u003cbr\u003e\nRS485 isolated communication port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus-RTU; it can remote control genset start\/stop, ATS close and open;\u003cbr\u003e\n\u003cbr\u003e\nETHERNET port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus TCP\/IP; it can remote control genset start\/stop, ATS close and open;\u003cbr\u003e\n\u003cbr\u003e\nSuitable for multiple AC system types (3Ph 4W, 3Ph 3W, Single Phase 2W, 2 Ph 3W);\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107322204331,"sku":"HAT600RB","price":332.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/04012ab3-fb6f-5db9-ab04-ff75a61b6f84.png?v=1661950281"},{"product_id":"smartgen-hat600r-dual-power-ats-controller","title":"SmartGen HAT600R Dual Power ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\n\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 4\u003cbr\u003e\nProgrammable Output 6\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\/USB\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 198*154*54\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT600R Series Dual Power ATS Controller is an intelligent dual-supply synchronous transfer module integrating programmable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking. Automatic measurement and control reduce the incorrect operation. It is an ideal option for dual power transfer.\u003cbr\u003e\n\u003cbr\u003e\nHAT600P Series Dual Power ATS Controller is made by microprocessor as its core, which can accurately detect 2-way-3-phase voltage, make accurate and quick judgment and output passive control switch for occurred abnormal voltages (over\/under voltage, loss of phase, over\/under frequency). This controller is applicable for Mains-Mains, Mains-Gen, Gen-Gen power supply system and can be used for transfer switch of PC class, CB class, and CC class after full consideration on various ATS (Automatic Transfer System) applications; Meanwhile it realizes synchronous parallel transfer or in-phase transfer of two power supplies. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nWith the function of quick transfer, the automatic transfer response time is as low as 50ms, matching with the fast ATS switch, which can achieve the transfer time less than 100ms;\u003cbr\u003e\n\u003cbr\u003e\nIn-phase transfer function;\u003cbr\u003e\n\u003cbr\u003e\nSynchronous parallel transfer function (HAT600RS only), display the voltage difference, frequency difference and phase difference of two-way power supply;\u003cbr\u003e\n\u003cbr\u003e\nLCD 132x64 pixel with backlight, multiple language display (Simplified Chinese, English, Other), push button operation;\u003cbr\u003e\n\u003cbr\u003e\nLED lamp can directly display current ATS close\/open status, power status and whether load is power on;\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set to: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#);\u003cbr\u003e\n\u003cbr\u003e\nS1 master, or S2 master can be set; Auto Transfer Auto Restore and Auto Transfer Non Restore are fitted for master power;\u003cbr\u003e\n\u003cbr\u003e\nMeasure and display 2-way 3 phase Voltage, Frequency, and Phase Sequence Status;\u003cbr\u003e\n\u003cbr\u003e\nCollect and display load active power, reactive power, apparent power, power factor and current;\u003cbr\u003e\n\u003cbr\u003e\nIndependent overcurrent warning or trip alarm functions for S1\/S2;\u003cbr\u003e\n\u003cbr\u003e\nNEL trip function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nLoad voltage monitoring function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of accumulated active power, accumulated reactive power, accumulated close times is fitted;\u003cbr\u003e\n\u003cbr\u003e\nEach phase voltage of S1\/S2, wave distortion rate of load current and 3-21 odd times harmonic percentage can be measured;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of current power supply time and S1\/S2 continuous power supply time is available;\u003cbr\u003e\n\u003cbr\u003e\nFor energy saving switch, users can wait for and close the switch until PF (close is ready) signal is active;\u003cbr\u003e\n\u003cbr\u003e\nOver\/under voltage, over\/under frequency, loss of phase, reverse phase sequence monitoring functions are fitted;\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual transfer is fitted, so that breaker can be forced to close or open in manual mode;\u003cbr\u003e\n\u003cbr\u003e\nAll parameters can be configured on site; password is used to verify in case of non professionals wrong operation;\u003cbr\u003e\n\u003cbr\u003e\nCustom start screen function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done manually on site to conduct genset start\/stop operations;\u003cbr\u003e\n\u003cbr\u003e\nSwitch re-close and breakout re-close functions are fitted;\u003cbr\u003e\n\u003cbr\u003e\nClose output can be set to pulse or continuous output;\u003cbr\u003e\n\u003cbr\u003e\nApplicable for switches of PC class two segments, PC class three segments, CB class and CC class;\u003cbr\u003e\n\u003cbr\u003e\n2 circuit N wire isolated design;\u003cbr\u003e\n\u003cbr\u003e\nReal time clock display, and event log function, which can record 200 data circularly;\u003cbr\u003e\n\u003cbr\u003e\nBlack box function, which can record 5 sets of events of ATS transfer, and 60 detailed data of 50s before one set occurs and 10s after the event;\u003cbr\u003e\n\u003cbr\u003e\nScheduled run\/not run function for genset, run for once, run monthly or weekly, and run on load or unload can also be set;\u003cbr\u003e\n\u003cbr\u003e\nTwo gensets can be controlled and cycle run, master run, and balanced time run can be realized.\u003cbr\u003e\n\u003cbr\u003e\nWide DC supply range, maximum 80V DC input for transient;\u003cbr\u003e\n\u003cbr\u003e\nWide wire terminal space of AC input, maximum 625V voltage input;\u003cbr\u003e\n\u003cbr\u003e\nUSB port, provides convenience for on-site debugging, and parameter or software upgrade;\u003cbr\u003e\n\u003cbr\u003e\nRS485 isolated communication port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus-RTU; it can remote control genset start\/stop, ATS close and open;\u003cbr\u003e\n\u003cbr\u003e\nETHERNET port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus TCP\/IP; it can remote control genset start\/stop, ATS close and open;\u003cbr\u003e\n\u003cbr\u003e\nSuitable for multiple AC system types (3Ph 4W, 3Ph 3W, Single Phase 2W, 2 Ph 3W);\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107323449515,"sku":"HAT600R","price":314.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/85119075-f29f-5c6a-8479-6bd830d0eae0.png?v=1661950343"},{"product_id":"smartgen-hat600pb-dual-power-synchronous-ats-controller","title":"SmartGen HAT600PB Dual Power Synchronous ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 4\u003cbr\u003e\nProgrammable Output 6\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nOver Current Warn ●\u003cbr\u003e\nCurrent and Power Display ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\/USB\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 198*154*54\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT600P Series Dual Power Synchronous ATS Controller is an intelligent dual-supply synchronous transfer module integrating programmable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking. Automatic measurement and control reduces incorrect operation. It is an ideal option for dual power transfer.\u003cbr\u003e\n\u003cbr\u003e\nHAT600P Series Dual Power Synchronous ATS Controller is made by microprocessor as its core, which can accurately detect 2-way-3-phase voltage, make accurate judgment and output passive control switch for occurred abnormal voltages (overvoltage, undervoltage, loss of phase, overfrequency and underfrequency). This controller is applicable for Mains-Mains, Mains-Gen, Gen-Gen power supply system and can be used for transfer switch of PC class, CB class, and CC class after full consideration on various ATS (Automatic Transfer System) applications; Meanwhile it realizes synchronous transfer of two power supplies. It have compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\nMODEL COMPARISON\u003cbr\u003e\n\u003cbr\u003e\nItem HAT600P HAT600PB HAT600PI HAT600PBI HAT600PS\u003cbr\u003e\nDC Supply ? ? ? ? ?\u003cbr\u003e\nAC Supply(LN90V~300V)\u003cbr\u003e\n?\u003cbr\u003e\n? ?\u003cbr\u003e\nCurrent Monitor\u003cbr\u003e\n\u003cbr\u003e\n? ? ?\u003cbr\u003e\nSynch. Transfer\u003cbr\u003e\n\u003cbr\u003e\n?\u003cbr\u003e\nInput Port No.(Fixed+Flexible) 2+4 2+4 2+4 2+4 2+4\u003cbr\u003e\nOutput Port No.(Fixed+Flexible) 2+6 2+6 2+6 2+6 2+6\u003cbr\u003e\nGenset Control ? ? ? ? ?\u003cbr\u003e\nRS485 ? ? ? ? ?\u003cbr\u003e\nUSB ? ? ? ? ?\u003cbr\u003e\nEHTERNET\u003cbr\u003e\n\u003cbr\u003e\n? ?\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nLCD 132x64 pixel with backlight, multiple language display (Simplified Chinese, English, Other), push button operation.\u003cbr\u003e\n\u003cbr\u003e\nLED lamp can directly display current ATS close\/open status, power status and whether load is power on.\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set to: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#).\u003cbr\u003e\n\u003cbr\u003e\nS1 master, or S2 master can be set; Auto Transfer Auto Recover and Auto Transfer Non Recover are fitted for master power.\u003cbr\u003e\n\u003cbr\u003e\nMeasure and display 2-way 3 phase Voltage, Frequency, and Phase Sequence Status.\u003cbr\u003e\n\u003cbr\u003e\nCollect and display load active power, reactive power, apparent power, power factor and current.\u003cbr\u003e\n\u003cbr\u003e\nIndependent overcurrent warning or trip alarm functions for S1\/S2.\u003cbr\u003e\n\u003cbr\u003e\nNEL trip function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nLoad voltage monitoring function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nDisplay of accumulated active power, accumulated reactive power, accumulated close times is fitted.\u003cbr\u003e\n\u003cbr\u003e\nEach phase voltage of S1\/S2, wave distortion rate of load current and 3-21 odd times harmonic percentage can be measured.\u003cbr\u003e\n\u003cbr\u003e\nDisplay of current power supply time and S1\/S2 continuous power supply time is available.\u003cbr\u003e\n\u003cbr\u003e\nAutomatic and manual synchronous transfer function is applicable, and the difference of voltage, frequency and phase of two circuits can be displayed.\u003cbr\u003e\n\u003cbr\u003e\nFor energy saving switch, users can wait for and close the switch until PF (close is ready) signal is active.\u003cbr\u003e\n\u003cbr\u003e\nOvervoltage, undervoltage, overfrequency, underfrequency, loss of phase, reverse phase sequence functions are fitted.\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual transfer is fitted, so that breaker can be forced to close or open in manual mode.\u003cbr\u003e\n\u003cbr\u003e\nAll parameters can be configured on site; password is used to verify in case of non professionals wrong operation.\u003cbr\u003e\n\u003cbr\u003e\nCustom start screen function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done manually on site to conduct genset start\/stop operations.\u003cbr\u003e\n\u003cbr\u003e\nSwitch re-close and breakout re-close functions are fitted.\u003cbr\u003e\n\u003cbr\u003e\nClose output can be set to pulse or continuous output.\u003cbr\u003e\n\u003cbr\u003e\nApplicable for switches of PC class two segments, PC class three segments, CB class and CC class.\u003cbr\u003e\n\u003cbr\u003e\n2 circuit N wire isolated design.\u003cbr\u003e\n\u003cbr\u003e\nReal time clock display, and event log function, which can record 200 data circularly.\u003cbr\u003e\n\u003cbr\u003e\nBlack box function, which can record 5 sets of events of ATS transfer, and 60 detailed data of 50s before one set occurs and 10s after the event.\u003cbr\u003e\n\u003cbr\u003e\nScheduled run\/not run function for genset, run for once, run monthly or weekly, and run on load or unload can also be set.\u003cbr\u003e\n\u003cbr\u003e\nTwo gensets can be controlled and cycle run, master run, and balanced time run can be realized.\u003cbr\u003e\n\u003cbr\u003e\nWide DC supply range, maximum 80V DC input for transient.\u003cbr\u003e\n\u003cbr\u003e\nWide wire terminal space of AC input, maximum 625V voltage input.\u003cbr\u003e\n\u003cbr\u003e\nUSB port, provides convenience for on-site debugging, and parameter or software upgrade.\u003cbr\u003e\n\u003cbr\u003e\nRS485 isolated communication port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus-RTU; it can remote control genset start\/stop, ATS close and open.\u003cbr\u003e\n\u003cbr\u003e\nETHERNET port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus TCP\/IP; it can remote control genset start\/stop, ATS close and open.\u003cbr\u003e\n\u003cbr\u003e\nSuitable for multiple AC system types (3Ph 4W, 3Ph 3W, Single Phase 2W, 2 Ph 3W).\u003cbr\u003e\n\u003cbr\u003e\nMaster and backup power supply can be set; ATS can normally work if one circuit is normal.\u003cbr\u003e\n\u003cbr\u003e\nController uses metal clips to fix.\u003cbr\u003e\n\u003cbr\u003e\nModular structure design, anti-flammable ABS shell, pluggable wire terminal, built-in installation method; structure is compact and installation is easy.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107330592939,"sku":"HAT600PB","price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/bbf6970b-e7b5-53c5-bb06-5df067377db9.png?v=1661950503"},{"product_id":"smartgen-hat600nb-ats-controller","title":"SmartGen HAT600NB ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(128*64)\u003cbr\u003e\nLanguage Chinese\/English\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface LINK\/RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSwitch Over Priority ●\u003cbr\u003e\nApplicable Switch Type All types\u003cbr\u003e\nDC Supply DC(8?35)V\/AC 220V\u003cbr\u003e\nCase Dimensions(mm) 209*153*55(L*W*H)\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT600N series ATS controller is intelligent dual-supply module with programmable function, automatic measurement, LCD display, and digital communication. It combines digital intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003cbr\u003e\n\u003cbr\u003e\nHAT600N series ATS controller is made of microprocessor as its core, can accurately detect extended-spectrum 2-way-3-phase voltage and also make accurate judgment and output passive control switch under the abnormal voltage (over and under voltage, miss phase and over and under frequency). This controller has full consideration in various application of ATS (automatic transfer system) can be directly used for Intelligent ATS, Contactor ATS, Circuit Break ATS etc. It have compact structure, advanced circuits, simple wiring and high reliability, be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\n1. PERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n1) System type can set for: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#).\u003cbr\u003e\n2) Backlit 128x64 LCD, optional Chinese and English display, push-button operation.\u003cbr\u003e\n3) Measure and display 2-way 3 phase Voltage and Frequency:\u003cbr\u003e\n4) Measure and display active power, apparent power, power factor and 3 phase current;\u003cbr\u003e\n5) Over current alarm;\u003cbr\u003e\n6) Over\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection.\u003cbr\u003e\n7) Automatic\/Manual mode. In manual mode, can force switch to close or open;\u003cbr\u003e\n8) All parameters can be set on site. With Two different passwords which ensures authorized staff operation only.\u003cbr\u003e\n9) During genset testing ATS controller can be set either on On-load or Off-load mode.\u003cbr\u003e\n10) ATS Controller has function of automatic Re-closing.\u003cbr\u003e\n11) Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n12) Applicable for ATS of one neutral position, two neutral position and change over.\u003cbr\u003e\n13) Applicable for 2 isolated neutral line for Generator and Mains.\u003cbr\u003e\n14) Real-time clock (RTC).\u003cbr\u003e\n15) Event log can record 99 items circularly.\u003cbr\u003e\n16) Timely schedule can be set on monthly or weekly basis and trial can be set as with on- load or off -load.\u003cbr\u003e\n17) Can control two generators to work in a cycle, even the genset running time and crank rest time can be set.\u003cbr\u003e\n18) Widely range of DC power supply (8V to 35V). Max.80V DC input can be endured in an instant, or be supplied via HWS560 module (input AC 85V~560V, output DC 12V).\u003cbr\u003e\n19) Wide space between connecting terminals of AC input. Max.625V input voltage.\u003cbr\u003e\n20) With standard isolated RS485 communication interface. With \"remote controlling, remote measuring, remote communication\" function by the ModBus communication protocol.\u003cbr\u003e\n21) Can check the current status of controller (including switch digital input, over Voltage, and under Voltage etc.).\u003cbr\u003e\n22) Suitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003cbr\u003e\n23) Modular design, flame-resisting ABS plastic shell, plug-in terminals and embedded installation. Compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107331969195,"sku":"HAT600NB","price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/30554e85-60b8-59c2-9631-5354822f42e5.png?v=1661950552"},{"product_id":"smartgen-hat700-ats-controller","title":"SmartGen HAT700 ATS controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface LINK\/RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSwitch Over Priority ●\u003cbr\u003e\nApplicable Switch Type PC Two-stage, PC Three-stage, CB and CC switch\u003cbr\u003e\nDC Supply DC(8-35)V\u003cbr\u003e\nCase Dimensions(mm) 197*152*47\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT700 series ATS controller is intelligent dual-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digital, intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003cbr\u003e\n\u003cbr\u003e\nThe powerful Microprocessor contained within the unit allows for precision voltage (2-way-3-phase) measuring and make accurate judgment; in addition, the corresponding digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase and other abnormal condition occurs. This controller has full consideration in various application of ATS (automatic transfer system) and can be directly used for PC ATS, CB ATS, CC ATS etc. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical devices, automatic control and testing system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n1. System type can set as: S1 (Mains) \u0026amp; S2 (Mains), S1 (Mains) \u0026amp; S2 (Generator), S1 (Generator) \u0026amp; S2 (Mains), S1 (Generator) \u0026amp; S2 (Generator).\u003cbr\u003e\n2. 132x64 LCD with backlight, multilingual interface (including English, Chinese or other languages), push-button operation.\u003cbr\u003e\n3. Collect and display 2-way 3-phase Voltage, Frequency and Phase.\u003cbr\u003e\n4. Collect and display Active Power, Reactive Power, Apparent Power, Power Factor and Current.\u003cbr\u003e\n5.S1\/S2 separated over current warning\/ trip alarm.\u003cbr\u003e\n6. NEL (Non-essential Load) trip function.\u003cbr\u003e\n7. Display S1\/S2 Total kW Energy, Total kvar Energy, Total Close Times.\u003cbr\u003e\n8. Display continuous power supply time and S1\/S2 total power supply time.\u003cbr\u003e\n9. Sync Transfer function; in addition, Voltage Difference, Frequency Difference and Phase Difference can be displayed.\u003cbr\u003e\n10. For Stored-Energy type ATS, its close relay will active after the PF Input is active.\u003cbr\u003e\n11. Over\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection.\u003cbr\u003e\n12. Phase Sequence Transfer function.\u003cbr\u003e\n13. Automatic\/Manual mode. In manual mode, can force the switch to close or open;\u003cbr\u003e\n14. All parameters can be set on site. Passwords authentication ensures authorized staff operation only.\u003cbr\u003e\n15. The genset can be Manual Test on site to achieve start\/stop operation.\u003cbr\u003e\n16. ATS Controller has function of automatic Re-closing.\u003cbr\u003e\n17. Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n18. Applicable for PC Three-stage, PC Two-stage, CB and CC switch.\u003cbr\u003e\n19. Applicable for 2 isolated neutral line.\u003cbr\u003e\n20. Real-time clock (RTC); Event log Function (Event log can record 99 items circularly).\u003cbr\u003e\n21. Scheduled Run \u0026amp; Scheduled Not Run (can be set as start genset once a day\/week\/month whether with load or not).\u003cbr\u003e\n22. Can control two generators to work as Cycle Run mode, Master Run mode and Balance Run mode.\u003cbr\u003e\n23. Widely power supply range DC(8~35)V allows the controller can bear 80V instantaneous current.\u003cbr\u003e\n24. Large terminal space allows the controller can bear maximum 625V input voltage.\u003cbr\u003e\n25. With RS485 isolated communication interface. With \"remote controlling, remote measuring, remote communication, remote regulating\" function by the ModBus communication protocol. Can remote start\/stop the genset and remote control the ATS to close or open.\u003cbr\u003e\n26. Suitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003cbr\u003e\n27. Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting?compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107332952235,"sku":"HAT700","price":262.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/7546128f-f07e-5bf5-8f12-3f50dee5e6d3.png?v=1661950589"},{"product_id":"smartgen-hat600p-dual-power-synchronous-ats-controller","title":"SmartGen HAT600P Dual Power Synchronous ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 4\u003cbr\u003e\nProgrammable Output 6\u003cbr\u003e\nOver Current Warn ●\u003cbr\u003e\nCurrent and Power Display ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\/USB\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nDC Supply DC(8?35)V\u003cbr\u003e\nCase Dimensions(mm) 198*154*54\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT600P Series Dual Power Synchronous ATS Controller is an intelligent dual-supply synchronous transfer module integrating programmable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking. Automatic measurement and control reduces incorrect operation. It is an ideal option for dual power transfer.\u003cbr\u003e\n\u003cbr\u003e\nHAT600P Series Dual Power Synchronous ATS Controller is made by microprocessor as its core, which can accurately detect 2-way-3-phase voltage, make accurate judgment and output passive control switch for occurred abnormal voltages (overvoltage, undervoltage, loss of phase, overfrequency and underfrequency). This controller is applicable for Mains-Mains, Mains-Gen, Gen-Gen power supply system and can be used for transfer switch of PC class, CB class, and CC class after full consideration on various ATS (Automatic Transfer System) applications; Meanwhile it realizes synchronous transfer of two power supplies. It have compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\nMODEL COMPARISON\u003cbr\u003e\n\u003cbr\u003e\nItem HAT600P HAT600PB HAT600PI HAT600PBI HAT600PS\u003cbr\u003e\nDC Supply ? ? ? ? ?\u003cbr\u003e\nAC Supply(LN90V~300V)\u003cbr\u003e\n?\u003cbr\u003e\n? ?\u003cbr\u003e\nCurrent Monitor\u003cbr\u003e\n\u003cbr\u003e\n? ? ?\u003cbr\u003e\nSynch. Transfer\u003cbr\u003e\n\u003cbr\u003e\n?\u003cbr\u003e\nInput Port No.(Fixed+Flexible) 2+4 2+4 2+4 2+4 2+4\u003cbr\u003e\nOutput Port No.(Fixed+Flexible) 2+6 2+6 2+6 2+6 2+6\u003cbr\u003e\nGenset Control ? ? ? ? ?\u003cbr\u003e\nRS485 ? ? ? ? ?\u003cbr\u003e\nUSB ? ? ? ? ?\u003cbr\u003e\nEHTERNET\u003cbr\u003e\n\u003cbr\u003e\n? ?\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nLCD 132x64 pixel with backlight, multiple language display (Simplified Chinese, English, Other), push button operation.\u003cbr\u003e\n\u003cbr\u003e\nLED lamp can directly display current ATS close\/open status, power status and whether load is power on.\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set to: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#).\u003cbr\u003e\n\u003cbr\u003e\nS1 master, or S2 master can be set; Auto Transfer Auto Recover and Auto Transfer Non Recover are fitted for master power.\u003cbr\u003e\n\u003cbr\u003e\nMeasure and display 2-way 3 phase Voltage, Frequency, and Phase Sequence Status.\u003cbr\u003e\n\u003cbr\u003e\nCollect and display load active power, reactive power, apparent power, power factor and current.\u003cbr\u003e\n\u003cbr\u003e\nIndependent overcurrent warning or trip alarm functions for S1\/S2.\u003cbr\u003e\n\u003cbr\u003e\nNEL trip function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nLoad voltage monitoring function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nDisplay of accumulated active power, accumulated reactive power, accumulated close times is fitted.\u003cbr\u003e\n\u003cbr\u003e\nEach phase voltage of S1\/S2, wave distortion rate of load current and 3-21 odd times harmonic percentage can be measured.\u003cbr\u003e\n\u003cbr\u003e\nDisplay of current power supply time and S1\/S2 continuous power supply time is available.\u003cbr\u003e\n\u003cbr\u003e\nAutomatic and manual synchronous transfer function is applicable, and the difference of voltage, frequency and phase of two circuits can be displayed.\u003cbr\u003e\n\u003cbr\u003e\nFor energy saving switch, users can wait for and close the switch until PF (close is ready) signal is active.\u003cbr\u003e\n\u003cbr\u003e\nOvervoltage, undervoltage, overfrequency, underfrequency, loss of phase, reverse phase sequence functions are fitted.\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual transfer is fitted, so that breaker can be forced to close or open in manual mode.\u003cbr\u003e\n\u003cbr\u003e\nAll parameters can be configured on site; password is used to verify in case of non professionals wrong operation.\u003cbr\u003e\n\u003cbr\u003e\nCustom start screen function is fitted.\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done manually on site to conduct genset start\/stop operations.\u003cbr\u003e\n\u003cbr\u003e\nSwitch re-close and breakout re-close functions are fitted.\u003cbr\u003e\n\u003cbr\u003e\nClose output can be set to pulse or continuous output.\u003cbr\u003e\n\u003cbr\u003e\nApplicable for switches of PC class two segments, PC class three segments, CB class and CC class.\u003cbr\u003e\n\u003cbr\u003e\n2 circuit N wire isolated design.\u003cbr\u003e\n\u003cbr\u003e\nReal time clock display, and event log function, which can record 200 data circularly.\u003cbr\u003e\n\u003cbr\u003e\nBlack box function, which can record 5 sets of events of ATS transfer, and 60 detailed data of 50s before one set occurs and 10s after the event.\u003cbr\u003e\n\u003cbr\u003e\nScheduled run\/not run function for genset, run for once, run monthly or weekly, and run on load or unload can also be set.\u003cbr\u003e\n\u003cbr\u003e\nTwo gensets can be controlled and cycle run, master run, and balanced time run can be realized.\u003cbr\u003e\n\u003cbr\u003e\nWide DC supply range, maximum 80V DC input for transient.\u003cbr\u003e\n\u003cbr\u003e\nWide wire terminal space of AC input, maximum 625V voltage input.\u003cbr\u003e\n\u003cbr\u003e\nUSB port, provides convenience for on-site debugging, and parameter or software upgrade.\u003cbr\u003e\n\u003cbr\u003e\nRS485 isolated communication port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus-RTU; it can remote control genset start\/stop, ATS close and open.\u003cbr\u003e\n\u003cbr\u003e\nETHERNET port, makes the controller has remote control, remote communication, remote measuring, remote debugging functions by ModBus TCP\/IP; it can remote control genset start\/stop, ATS close and open.\u003cbr\u003e\n\u003cbr\u003e\nSuitable for multiple AC system types (3Ph 4W, 3Ph 3W, Single Phase 2W, 2 Ph 3W).\u003cbr\u003e\n\u003cbr\u003e\nMaster and backup power supply can be set; ATS can normally work if one circuit is normal.\u003cbr\u003e\n\u003cbr\u003e\nController uses metal clips to fix.\u003cbr\u003e\n\u003cbr\u003e\nModular structure design, anti-flammable ABS shell, pluggable wire terminal, built-in installation method; structure is compact and installation is easy.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107334361259,"sku":"HAT600P","price":262.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/9234c030-82d3-5c64-94f9-13d01e4794cd.png?v=1661950630"},{"product_id":"smartgen-hat560nbc-ats-controller","title":"SmartGen HAT560NBC ATS controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface LINK\/RS485\u003cbr\u003e\nProgrammable Interface LINK\/RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSwitch Over Priority ●\u003cbr\u003e\nApplicable Switch Type PC Two-stage, PC Three-stage, CB and CC switch\u003cbr\u003e\nDC Supply DC(8-35)V\u003cbr\u003e\nCase Dimensions(mm) 139*120*48\u003cbr\u003e\nPanel Cutout(mm) 130*111\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT560NC series ATS controller is intelligent dual-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digital, intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003cbr\u003e\n\u003cbr\u003e\nThe powerful Microprocessor contained within the unit allows for precision voltage (2-way-3-phase\/single phase) measuring and make accurate judgment; in addition, the corresponding digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase and other abnormal condition occurs. This controller has full consideration in various application of ATS (automatic transfer system) and can be directly used for specialized ATS, Contactor ATS, Air break ATS etc. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical devices, automatic control and testing system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS:\u003cbr\u003e\n\u003cbr\u003e\n1. System type can set as: Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#).\u003cbr\u003e\n2. 132x64 LCD with backlight, optional Chinese and English display, push-button operation.\u003cbr\u003e\n3. Measure and display 2-way 3 phase Voltage and Frequency:\u003cbr\u003e\n4. Over\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection.\u003cbr\u003e\n5. Automatic\/Manual mode. In manual mode, can force the switch to close or open;\u003cbr\u003e\n6. All parameters can be set on site. With Two different passwords which ensures authorized staff operation only.\u003cbr\u003e\n7. During commissioning, the genset can be set either on On-load or Off-load mode.\u003cbr\u003e\n8. ATS Controller has function of automatic Re-closing.\u003cbr\u003e\n9. Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n10. Applicable for ATS of one neutral position, two neutral position and non-position.\u003cbr\u003e\n11. Applicable for 2 isolated neutral line.\u003cbr\u003e\n12. Real-time clock (RTC).\u003cbr\u003e\n13. Event log can record 50 items circularly.\u003cbr\u003e\n14. Scheduled start \u0026amp; stop generator (can be set as start genset once a day\/week\/month whether with load or not).\u003cbr\u003e\n15. Can control two generators to work in a cycle, even the genset running time and crank rest time can be set.\u003cbr\u003e\n16. Optional AC system or DC system.\u003cbr\u003e\n17. With standard LINK communication interface. With \"remote controlling, remote measuring, remote communication\" function by the ModBus communication protocol. Can remote start\/stop the genset and remote control the ATS to close or open.\u003cbr\u003e\n18. With RS485 isolated communication interface. With \"remote controlling, remote measuring, remote communication\" function by the ModBus communication protocol; or remote measuring the status of incoming cabinet and remote controlling the ATS to close\/open by the front-end intelligent device (YD\/T 1363.3?2005) protocol.\u003cbr\u003e\n19. Can check the current status of controller (digital input port, digital output port, over voltage, under voltage, over frequency, under frequency etc.).\u003cbr\u003e\n20. Suitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003cbr\u003e\n22. Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting?compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107342717099,"sku":"HAT560NBC","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/e4e21a95-8718-5539-b11f-32b3dd9fdc42.png?v=1661950829"},{"product_id":"smartgen-hat560n-ats-controller","title":"SmartGen HAT560N ATS controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface LINK\u003cbr\u003e\nProgrammable Interface LINK\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSwitch Over Priority ●\u003cbr\u003e\nApplicable Switch Type PC Two-stage, PC Three-stage, CB and CC switch\u003cbr\u003e\nDC Supply DC(8-35)V\u003cbr\u003e\nCase Dimensions(mm) 139*120*48\u003cbr\u003e\nPanel Cutout(mm) 130*111\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT560N series ATS controller is intelligent dual-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digital, intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.\u003cbr\u003e\n\u003cbr\u003e\nThe powerful Microprocessor contained within the unit allows for precision voltage (2-way-3-phase\/single phase) measuring and make accurate judgment; in addition, the corresponding digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase and other abnormal condition occurs. This controller has full consideration in various application of ATS (automatic transfer system) and can be directly used for specialized ATS, Contactor ATS, Air break ATS etc. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical devices, automatic control and testing system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS:\u003cbr\u003e\n1. System type can set as: Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#).\u003cbr\u003e\n2. 132x64 LCD with backlight, optional Chinese and English display, push-button operation.\u003cbr\u003e\n3. Measure and display 2-way 3 phase Voltage and Frequency:\u003cbr\u003e\n4. Over\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection.\u003cbr\u003e\n5. Automatic\/Manual mode. In manual mode, can force the switch to close or open;\u003cbr\u003e\n6. All parameters can be set on site. With Two different passwords which ensures authorized staff operation only.\u003cbr\u003e\n7. During commissioning, the genset can be set either on On-load or Off-load mode.\u003cbr\u003e\n8. ATS Controller has function of automatic Re-closing.\u003cbr\u003e\n9. Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n10. Applicable for ATS of one neutral position, two neutral position and non-position.\u003cbr\u003e\n11. Applicable for 2 isolated neutral line.\u003cbr\u003e\n12. Real-time clock (RTC).\u003cbr\u003e\n13. Event log can record 50 items circularly.\u003cbr\u003e\n14. Scheduled start \u0026amp; stop generator (can be set as start genset once a day\/week\/month whether with load or not).\u003cbr\u003e\n15. Can control two generators to work in a cycle, even the genset running time and crank rest time can be set.\u003cbr\u003e\n16. Optional AC system or DC system.\u003cbr\u003e\n17. With standard LINK communication interface. With \"remote controlling, remote measuring, remote communication\" function by the ModBus communication protocol. Can remote start\/stop the genset and remote control the ATS to close or open.\u003cbr\u003e\n18. Can check the current status of controller (digital input port, digital output port, over voltage, under voltage, over frequency, under frequency etc.).\u003cbr\u003e\n19. Suitable for various AC systems (3 phase 4-wires, 3-phase 3-wires, single-phase 2-wire, and 2-phase 3-wire).\u003cbr\u003e\n20. Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting?compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107349794987,"sku":"HAT560N","price":192.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/9ce55897-68bf-5137-9391-9b6e0cd64b15.png?v=1661950997"},{"product_id":"smartgen-hat553-dual-power-ats-controller","title":"SmartGen HAT553 Dual power ATS controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English\u003cbr\u003e\nProgrammable Input 4\u003cbr\u003e\nProgrammable Output 6\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nVolt Freq Protection ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nApplicable Switch Type Two-stage?Three-stage\u003cbr\u003e\nCase Dimensions(mm) 139*120*50\u003cbr\u003e\nPanel Cutout(mm) 130*111\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT552\/HAT553 dual power ATS controller is a dual power transfer module integrated with configurable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking together, which realizes automation for measuring and control process, reducing artificial operation mistakes. It is the ideal product for dual power transfer. HAT552 is applicable for non-breaking switches, while HAT553 is applicable for non-breaking, one-breaking, and two-breaking switches.\u003cbr\u003e\n\u003cbr\u003e\nHAT552\/HAT553 dual power ATS controller is made with the microprocessor in the core, which can precisely measure 2-channel 3-phase voltages, make correct judgment and control outputs for occurred voltage abnormal (over voltage, under voltage, loss of phase, over frequency, under frequency, reverse phase sequence). It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building etc.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set to: Mains - Generator, Generator - Mains, Mains - Mains;\u003cbr\u003e\n\u003cbr\u003e\n132x64 LCD with backlight, optional Chinese and English display, push-button operation;\u003cbr\u003e\n\u003cbr\u003e\nMeasure and display 2-channel 3 phase voltage, frequency and phase sequence;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of A power\/B power accumulated close times;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of present continuous power supply time and A power\/B power accumulated power supply time;\u003cbr\u003e\n\u003cbr\u003e\nOver\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection function;\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual mode transfer function: in manual mode, user can control the switch to close or open;\u003cbr\u003e\n\u003cbr\u003e\nAll parameters are configurable. password verification is used to prevent non-professional error operations;\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done on site manually to execute genset start\/stop operations;\u003cbr\u003e\n\u003cbr\u003e\nSwitch Re-closing function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nBreaker close output can be set to pulse or steady output;\u003cbr\u003e\n\u003cbr\u003e\n2-channel N wire isolated design;\u003cbr\u003e\n\u003cbr\u003e\nReal-time clock (RTC) display, and event log function, which can record 50 data cyclically.\u003cbr\u003e\n\u003cbr\u003e\nScheduled start \u0026amp; stop generator function: running once monthly\/weekly, and onload\/offload running are configurable;\u003cbr\u003e\n\u003cbr\u003e\nAC supply power can be phase voltage (L, N), supply range: (170-277)V;\u003cbr\u003e\n\u003cbr\u003e\n1 RS485 isolated communication port, has \"remote control, remote measuring, remote communication, remote adjusting\" function with ModBus-RTU communication protocol; genset start, genset stop, ATS close\/open can be controlled remotely;\u003cbr\u003e\n\u003cbr\u003e\nSuitable for various AC system types (3 phase 4-wire, single-phase 2-wire, and 2-phase 3-wire);\u003cbr\u003e\n\u003cbr\u003e\nModular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting, compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107350352043,"sku":"HAT553","price":192.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/8ed4e65f-a19b-5f2e-9d5d-a9dd7f2cdf98.png?v=1661951030"},{"product_id":"smartgen-hat552-dual-power-ats-controller","title":"SmartGen HAT552 Dual Power ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(132*64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English\u003cbr\u003e\nProgrammable Input 3\u003cbr\u003e\nProgrammable Output 4\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nVolt Freq Protection ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nApplicable Switch Type Two-stage\u003cbr\u003e\nCase Dimensions(mm) 139*120*50\u003cbr\u003e\nPanel Cutout(mm) 130*111\u003cbr\u003e\nOperating Temp. (-25~+70)\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT552\/HAT553 dual power ATS controller is a dual power transfer module integrated with configurable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking together, which realizes automation for measuring and control process, reducing artificial operation mistakes. It is the ideal product for dual power transfer. HAT552 is applicable for non-breaking switches, while HAT553 is applicable for non-breaking, one-breaking, and two-breaking switches.\u003cbr\u003e\n\u003cbr\u003e\nHAT552\/HAT553 dual power ATS controller is made with the microprocessor in the core, which can precisely measure 2-channel 3-phase voltages, make correct judgment and control outputs for occurred voltage abnormal (over voltage, under voltage, loss of phase, over frequency, under frequency, reverse phase sequence). It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building etc.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set to: Mains - Generator, Generator - Mains, Mains - Mains;\u003cbr\u003e\n\u003cbr\u003e\n132x64 LCD with backlight, optional Chinese and English display, push-button operation;\u003cbr\u003e\n\u003cbr\u003e\nMeasure and display 2-channel 3 phase voltage, frequency and phase sequence;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of A power\/B power accumulated close times;\u003cbr\u003e\n\u003cbr\u003e\nDisplay of present continuous power supply time and A power\/B power accumulated power supply time;\u003cbr\u003e\n\u003cbr\u003e\nOver\/under voltage, loss of phase, reverse phase sequence, over\/under frequency protection function;\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual mode transfer function: in manual mode, user can control the switch to close or open;\u003cbr\u003e\n\u003cbr\u003e\nAll parameters are configurable. password verification is used to prevent non-professional error operations;\u003cbr\u003e\n\u003cbr\u003e\nCommissioning can be done on site manually to execute genset start\/stop operations;\u003cbr\u003e\n\u003cbr\u003e\nSwitch Re-closing function is fitted;\u003cbr\u003e\n\u003cbr\u003e\nBreaker close output can be set to pulse or steady output;\u003cbr\u003e\n\u003cbr\u003e\n2-channel N wire isolated design;\u003cbr\u003e\n\u003cbr\u003e\nReal-time clock (RTC) display, and event log function, which can record 50 data cyclically.\u003cbr\u003e\n\u003cbr\u003e\nScheduled start \u0026amp; stop generator function: running once monthly\/weekly, and onload\/offload running are configurable;\u003cbr\u003e\n\u003cbr\u003e\nAC supply power can be phase voltage (L, N), supply range: (170-277)V;\u003cbr\u003e\n\u003cbr\u003e\n1 RS485 isolated communication port, has \"remote control, remote measuring, remote communication, remote adjusting\" function with ModBus-RTU communication protocol; genset start, genset stop, ATS close\/open can be controlled remotely;\u003cbr\u003e\n\u003cbr\u003e\nSuitable for various AC system types (3 phase 4-wire, single-phase 2-wire, and 2-phase 3-wire);\u003cbr\u003e\n\u003cbr\u003e\nModular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting, compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107352809643,"sku":"HAT552","price":192.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/e1548cd6-4e4c-58fe-a39a-40e9fafc4909.png?v=1661951065"},{"product_id":"smartgen-hat530n-ats-controller","title":"SmartGen HAT530N ATS controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LED\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface LINK\u003cbr\u003e\nProgrammable Interface LINK\u003cbr\u003e\nSwitch Over Priority ?\u003cbr\u003e\nApplicable Switch Type NO Breaking ATS and ONE Breaking ATS\u003cbr\u003e\nCase Dimensions(mm) 139*120*50\u003cbr\u003e\nPanel Cutout(mm) 130*111\u003cbr\u003e\nOperating Temp. (-25~+70)?\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nThe powerful Microprocessor contained within the HAT530N ATS controller allows for precision voltage (2-way 3-phase\/single phase) measuring and make accurate judgment on abnormal voltage (power lost, over\/under voltage, over\/under frequency, loss of phase, phase sequence wrong) and control ATS to transfer after the delay has expired. This controller is suitable for NO Breaking ATS and ONE Breaking ATS. When #1 power is abnormal, the controller will send signal to start genset after the \"#1 abnormal delay\" has expired. \"Three remote\" (remote control, remote measurement and remote communication)\u003cbr\u003e\n\u003cbr\u003e\nFunction can be implemented with the help of LINK communication port.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nPerformance and characteristics:\u003cbr\u003e\nIts performance and characteristics are shown as below,\u003cbr\u003e\n\u003cbr\u003e\n1. Measure and display 2-way 3 phase Voltage and Frequency\u003cbr\u003e\n2. Over\/under voltage, loss of phase, phase sequence wrong, over\/under frequency protection function. As default, phase reverse sequence protection and over\/under frequency protection are disable; however, users can set the protection function as need.\u003cbr\u003e\n3. Parameters can be set via PC software using SG72 module (USB to LINK) or other converse module.\u003cbr\u003e\n4. The voltage normal delay of 1# or 2# can be set in (0~60) seconds and the Genset start delay can be set in (0~3600) seconds.\u003cbr\u003e\n5. The voltage abnormal delay of 1# or 2# can be set in (0~60) seconds and the Genset stop delay can be set in (0~3600) seconds.\u003cbr\u003e\n6. \"1# power priority\", \"Auto\/Manual\", \"No priority\" and \"2# power priority\" can be set via controller front panel.\u003cbr\u003e\n7. Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n8. Applicable for 2 isolated neutral line.\u003cbr\u003e\n9. Auto\/Manual mode. In manual mode, ATS transfer can be implemented via panel pushbutton.\u003cbr\u003e\n10. LEDs mounted on front panel can clearly show ATS running status.\u003cbr\u003e\n11. Forced Open input port been designed; When the input port is active, the switch will be Breaking position forcedly (woks for the ATS with Breaking Position).\u003cbr\u003e\n12. AUX.OUTPUT 1 and AUX.OUTPUT 2 can be configured to make it easy to transfer power supply.\u003cbr\u003e\n13. The output contact capacity of 1# and 2# power supply transfer relay (1#CLOSE, 2#CLOSE) is 5A AC250V, passive contact, can be directly used in driving switch to transfer.\u003cbr\u003e\n14. The output contact capacity of Genset start relay (GENS START) is 7A AC250V\/7A DC28V, passive N\/C contact.\u003cbr\u003e\n15. Suitable for various AC systems (3 phase 4-wires, 2-phase 3-wires and single-phase 2-wire).\u003cbr\u003e\n16. Modular design, retardant ABS plastic shell, pluggable terminal, built-in mounting?compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107384234155,"sku":"HAT530N","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/8821761e-daae-56a6-996c-4d75613c00d7.png?v=1661951618"},{"product_id":"smartgen-hat530nc-ats-controller","title":"SmartGen HAT530NC ATS controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LED\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\u003cbr\u003e\nSwitch Over Priority ?\u003cbr\u003e\nApplicable Switch Type NO Breaking ATS and ONE Breaking ATS\u003cbr\u003e\nCase Dimensions(mm) 139*120*50\u003cbr\u003e\nPanel Cutout(mm) 130*111\u003cbr\u003e\nOperating Temp. (-25~+70)?\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT530NC ATS Controller is composed of the core microprocessor, which can precisely measure 3-phase\/single phase voltage of 2 ways, make accurate judgment on abnormal voltage (power lost, over\/under voltage, over\/under frequency, loss of phase, phase sequence wrong), and control ATS to transfer after delay is expired. This controller is suitable for NO Breaking ATS and ONE Breaking ATS. When #1 power is abnormal, the controller will send signal to start genset after the \"#1 abnormal delay\" has expired. \"Three remotes\" (remote control, remote measurement and remote communication) functions can be implemented with the help of RS485 communication port.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nCollect 2-way 3 phase Voltage and Frequency:\u003cbr\u003e\n\u003cbr\u003e\n1# 2#\u003cbr\u003e\n\u003cbr\u003e\nLine voltage (Uab, Ubc, Uca) Line voltage (Uab, Ubc, Uca)\u003cbr\u003e\n\u003cbr\u003e\nPhase voltage (Ua, Ub, Uc) Phase voltage (Ua, Ub, Uc)\u003cbr\u003e\n\u003cbr\u003e\nFrequency Hz Frequency Hz\u003cbr\u003e\n\u003cbr\u003e\nOver\/under voltage, loss of phase, phase sequence wrong, over\/under frequency detection function. As default, phase reverse sequence detection and over\/under frequency detection are disable; however, users can set the function as you need.\u003cbr\u003e\n\u003cbr\u003e\nController running parameters can be set by upper computer testing software; At using, controller RS485 port shall connect upper computer by SG72 port module (USB transfers to RS485) or other transfer module.\u003cbr\u003e\n\u003cbr\u003e\nNormal delay of 1# power or 2# power can be set (Range: 0-60s); Genset crank delay can be set (Range: 0-3600s).\u003cbr\u003e\n\u003cbr\u003e\nAbnormal delay of 1# power or 2# power can be set (Range: 0-60s); Genset stop delay can be set (Range: 0-3600s).\u003cbr\u003e\n\u003cbr\u003e\n\"1# Master\", \"Auto\/Manual\", \"Each Backup\" and \"2# Master\" can be set via controller front panel, to realize 1# Master power supply, 2# Master power supply or backup for each other to supply power.\u003cbr\u003e\n\u003cbr\u003e\nClose output can be set to pulse or continuous output.\u003cbr\u003e\n\u003cbr\u003e\n2-way N wire isolated design.\u003cbr\u003e\n\u003cbr\u003e\nAuto\/Manual mode transfer. In manual mode, ATS transfer can be implemented via panel pushbutton.\u003cbr\u003e\n\u003cbr\u003e\nLEDs mounted on front panel can clearly show ATS running status.\u003cbr\u003e\n\u003cbr\u003e\nForced Open input port has been designed; When the input port is active, the switch will be Breaking position forcedly (woks only for the ATS with Breaking Position).\u003cbr\u003e\n\u003cbr\u003e\nAUX.OUTPUT 1 and AUX.OUTPUT 2 can be configured to make it easy to transfer power supply.\u003cbr\u003e\n\u003cbr\u003e\nThe output contact capacity of 1# and 2# power supply transfer relay (1#CLOSE, 2#CLOSE, OPEN) is 5A AC250V, passive contact, can be directly used in driving switch to transfer.\u003cbr\u003e\n\u003cbr\u003e\nThe output contact capacity of Genset start relay (GENS START) is 7A AC250V\/7A DC28V, passive N\/C contact.\u003cbr\u003e\n\u003cbr\u003e\nSuitable for various AC systems (3-phase 4-wire, single-phase 2-wire, 2-phase 3-wire and 3-phase 3-wire).\u003cbr\u003e\n\u003cbr\u003e\nModular design, retardant ABS plastic shell, pluggable terminal, built-in mounting?compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107386593451,"sku":"HAT530NC","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/01cd7b9b-9229-5885-9bc3-b0456d7aed0c.png?v=1661951652"},{"product_id":"smartgen-hat520n-dual-power-ats-controller","title":"SmartGen HAT520N Dual Power ATS controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\n\u003cbr\u003e\nDisplay LED\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface LINK\u003cbr\u003e\nProgrammable Interface LINK\u003cbr\u003e\nSwitch Over Priority ?\u003cbr\u003e\nApplicable Switch Type No break position\u003cbr\u003e\nDC Supply AC(170~277)V\u003cbr\u003e\nCase Dimensions(mm) 139*120*50(L*W*H)\u003cbr\u003e\nPanel Cutout(mm) 130*111\u003cbr\u003e\nOperating Temp. (-25~+70)?\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nThe powerful Microprocessor contained within the HAT520N ATS controller allows for precision voltage (2-way 3-phase\/single phase) measuring and make accurate judgment on abnormal voltage (power lost, over\/under voltage, over\/under frequency, loss of phase, phase sequence wrong) and control ATS to transfer after the delay has expired. This controller is suitable for NO Breaking ATS. When 1# power is abnormal, the controller will send signal to start genset after the \"1# abnormal delay\" has expired. \"Three remote\" (remote control, remote measurement and remote communication) function can be implemented with the help of LINK communication port.\u003cbr\u003e\n\u003cbr\u003e\n1 PERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\nHAT520N ATS controller owns performance and characteristics are shown as below,\u003cbr\u003e\n\u003cbr\u003e\n1) Measure and display 2-way 3 phase Voltage and Frequency:\u003cbr\u003e\n\u003cbr\u003e\n1# 2#\u003cbr\u003e\n\u003cbr\u003e\nLine voltage (Uab, Ubc, Uca) Line voltage (Uab, Ubc, Uca)\u003cbr\u003e\n\u003cbr\u003e\nPhase voltage (Ua, Ub, Uc) Phase voltage (Ua, Ub, Uc)\u003cbr\u003e\n\u003cbr\u003e\nFrequency Hz Frequency Hz\u003cbr\u003e\n2) Over\/under voltage, loss of phase, phase sequence wrong, over\/under frequency protection function. As default, phase sequence wrong protection and over\/under frequency protection are disable; however, users can set the protection function as need.\u003cbr\u003e\n3) Parameters can be set via PC software using SG72 module (USB to LINK) or other converse module.\u003cbr\u003e\n4) The voltage normal delay of 1# or 2#can be set in (0~60) seconds and the Genset start delay can be set in (0~3600) seconds.\u003cbr\u003e\n5) The voltage abnormal delay of 1# or 2#can be set in (0~60) seconds and the Genset stop delay can be set in (0~3600) seconds.\u003cbr\u003e\n6) \"1# power priority\", \"Auto\/Manual\", \"No priority\" and \"2#power priority\" can be set via controller front panel.\u003cbr\u003e\n7) Closing output signal can be set as on intervals or as continuous output.\u003cbr\u003e\n8) Applicable for 2 isolated neutral line.\u003cbr\u003e\n9) Auto\/Manual mode. In manual mode, ATS transfer 1# switch or 2# switch can be implemented via panel pushbutton.\u003cbr\u003e\n10) LEDs mounted on front panel can clearly show ATS running status.\u003cbr\u003e\n11) The output contactor capacity of 1# and 2#power supply transfer relay (1#CLOSE, 2#CLOSE) is 16A AC250V, volts-free contact, can be directly used in driving switch to transfer.\u003cbr\u003e\n12) The output contactor capacity of Genset start relay (GENS START) is 7A AC250V\/7A DC28V, volts-free N\/C contact.\u003cbr\u003e\n13) Suitable for various AC systems (3 phase 4-wires, 2-phase 3-wires and single-phase 2-wire).\u003cbr\u003e\n14) Modular design, self extinguishing ABS plastic shell, pluggable terminal, built-in mounting?compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107386757291,"sku":"HAT520N","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/65a7ebf5-90b8-5765-80a6-d11e5b87ee49.png?v=1661951666"},{"product_id":"smartgen-ata600-dual-power-switch-adapter","title":"SmartGen ATA821 Dual Power Switch Adapter","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nRated Working Voltage AC400V\u003cbr\u003e\nMax Working Current 10A\u003cbr\u003e\nCase Dimensions(mm) 144.4*252*75.3\u003cbr\u003e\nPanel Cutout(mm) 125*240\u003cbr\u003e\nOperating Temp. (-25~+70)?\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nATA821 Bus Tie Adapter for Dual Power Switch is a kind of adapter which makes convenience for connection between HAT821 dual power bus tie ATS controller and smart breaker, reducing a lot of field wiring work for users, not only labor saving, time saving but also reliable.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nSuitable for 3Ph 4W AC system;\u003cbr\u003e\n\u003cbr\u003e\nTwo integrated 400V\/50Hz\/10A circuits of air breaker, which are individually used to connect two circuits of AC power;\u003cbr\u003e\n\u003cbr\u003e\nAll-in-one integrated adaptor, which can simultaneously connect S1 breaker, S2 breaker and bus tie breaker;\u003cbr\u003e\n\u003cbr\u003e\nSuitable for HAT821 dual power bus tie ATS controller;\u003cbr\u003e\n\u003cbr\u003e\nCold rolled plate closure;\u003cbr\u003e\n\u003cbr\u003e\nWith screw installation method, adapter is fixed by 4 screws.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107389051051,"sku":"ATA821","price":97.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/d90c45b6-d352-55cd-b2dd-79c2c44555ef.png?v=1661951757"},{"product_id":"smartgen-ata600-dual-power-switch-adapter-1","title":"SmartGen ATA600 Dual Power Switch Adapter","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nRated Working Voltage AC400V\u003cbr\u003e\nMax Working Current 10A\u003cbr\u003e\nCase Dimensions(mm) 144.4*252*75.3\u003cbr\u003e\nPanel Cutout(mm) 125*240\u003cbr\u003e\nOperating Temp. (-25~+70)?\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nATA600 Dual Power Switch Adapter is a kind of adapter which makes convenience for connection between HAT600\/HAT600N\/HAT600P\/HAT700 dual power ATS controller and smart breaker, reducing a lot of field wiring work for users, not only labor saving, time saving but also reliable.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nSuitable for 3Ph 4W AC system;\u003cbr\u003e\n\u003cbr\u003e\nTwo integrated 400V\/50Hz\/10A circuits of air breaker, which are individually used to connect two circuits of AC power;\u003cbr\u003e\n\u003cbr\u003e\nAll-in-one integrated adaptor, which can simultaneously connect S1 breaker, and S2 breaker;\u003cbr\u003e\n\u003cbr\u003e\nSuitable for HAT600\/HAT600N\/HAT600P\/HAT700 dual power ATS controller;\u003cbr\u003e\n\u003cbr\u003e\nCold rolled plate closure;\u003cbr\u003e\n\u003cbr\u003e\nWith screw installation method, adapter is fixed by 4 screws.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":42107394916523,"sku":"ATA600","price":84.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/products\/3757500d-d669-5230-8e7d-bdd88fb56e37.png?v=1661951898"},{"product_id":"smartgen-hat310-s01-ats-controller-120-240vac","title":"SmartGen HAT310-S01 ATS Controller 120\/240VAC","description":"\u003cp\u003eProduct Overview:\u003cbr\u003e\n\u003cbr\u003e\nHAT310-120V ATS Controller is suitable for 2-stage of PC, and ATS of CC class (close signal isconstant output). It can accurately detect 3-phase 4-wire mains voltage and generator single phase voltage. When mains under voltage and loss of phase occurred, HAT310-120V will control ATS transferafter delay. If mains are unavailable, the controller has the function to initiate signals to start gen-set.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nHAT310-120V controller can detect 3-phase 4-wire mains voltage\/generator single phasevoltage and control ATS.\u003cbr\u003e\nMain characteristics are as follows,\u003cbr\u003e\n1) With aotomatic charge and automatic recorvery function.\u003cbr\u003e\n2) With under volatge and loss of phase detection function.\u003cbr\u003e\n3) LED indicators on the pannal can show working status of controller clearly.\u003cbr\u003e\n4) Applicable for 2 isolated neutral line.\u003cbr\u003e\n5) Mains normal delay configured via potentiometer (range: 1~60s), and generator normal delay viapotentiometer (range: 1~60s)\u003cbr\u003e\n6) Mians is unavailable, if any phase voltage belows minimum working voltage or phase loss occurredgen-set will be started.\u003cbr\u003e\n7) Output contact capacity of mains and generator transfer relay is 16A AC120V, which can directlyused to drive switch conversion.\u003cbr\u003e\n8) Output contact capacity of GENS START relay is 16A AC120V, it is volt freenormally-open\/normally-closed contect.\u003cbr\u003e\n9) Strong anti-electromagnetic interference performance enable controller to use in the enviromentwith strong electromagnetic interfrence.\u003cbr\u003e\n10) Modular design, self extinguishing ABS plastic shell, pluggable terminal, compact structure;\u003cbr\u003e\n11) Two installation ways: internal 35mm slideway and internal screw mounting.\u003cbr\u003e\n\u003cbr\u003e\nSPECIFICATION\u003cbr\u003e\n\u003cbr\u003e\nOperating Voltage - AC power A1N1\/A2N2 supply. Rated AC120V (range: AC90~150V)\u003cbr\u003e\nPower Consumption Under rated voltage, power consumption of voltage circuit is not more than 2W\u003cbr\u003e\nAC Voltage Input: - 3-phase 4-wire (120\/208 VAC),\u003cbr\u003e\n2 phase 3-wire (120\/240VAC),\u003cbr\u003e\nsingle-phase 2-wire (120VAC):\u003cbr\u003e\nAC70V - AC150V (ph-N)\u003cbr\u003e\nAC Frequency - 50\/60Hz\u003cbr\u003e\nGens-set Starter Relay - 16A 120V AC Volts free output (Normally close)\u003cbr\u003e\nMains Close Relay - 16A 120V AC AC Supply output (Normally open)\u003cbr\u003e\nGen Close Relay - 16A 120V AC AC Supply output (Normally open)\u003cbr\u003e\nCase Dimensions - 110mmx77.5mmx55mm\u003cbr\u003e\nScrew Mounting Dimensions - 65mmx65.1mm\u003cbr\u003e\nWorking Conditions - Temperature: (-25~+70)°C;\u003cbr\u003e\n- Humidity: (20~93)%RH\u003cbr\u003e\nStorage Condition - Temperature: (-25~+70)°C\u003cbr\u003e\nInsulation Strength - Apply AC1.5kV voltage between high voltage terminal and low voltage terminal; The leakage current is not more than 3mA within 1min.\u003cbr\u003e\nWeight - 0.2kg\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":43152261415083,"sku":"HAT310S01","price":87.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/files\/97a9ab02-29cd-5f0b-96d5-28ac6a062382.jpg?v=1699620816"},{"product_id":"smartgen-hmat880-medium-voltage-bypass-ats-controller","title":"SmartGen HMAT880 Medium Voltage Bypass ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(240*128)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 12\u003cbr\u003e\nProgrammable Output 13\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nCurrent and Power Display ●\u003cbr\u003e\nOver Current Warn ●\u003cbr\u003e\nVolt Freq Protection ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nDC Supply DC12V\/24V\/48V\u003cbr\u003e\nCase Dimensions(mm) 260*180*54\u003cbr\u003e\nPanel Cutout(mm) 242*161\u003cbr\u003e\nOperating Temp. (-25~+70)℃\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHMAT880 Medium Voltage Bypass ATS Controller is a module that integrates programmable function, automatic measurement, PT break detection, load stepwise switch, LCD display and digital communication. It combines digital, intelligent and network technology, realizes automation of measurement and control process, thus reducing manual operation error, which is an ideal product for medium voltage bypass transfer.\u003cbr\u003e\n\u003cbr\u003e\nHMAT880 Medium Voltage Bypass ATS Controller is composed of microprocessor as the core, which can precisely detect 2-way 3-phase incoming voltage, make accurate judgment for voltage abnormal situations (over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence) and output passive control coil. It fully considers various applications in bypass switch and can be directly used for single bypass, dual bypass switch, also for manual\/remote control switch. With compact structure, advanced circuits, simple wiring and high reliability, it can be widely used in electric device, server supply and debugging system of electric power, telecom, petrochemical industry, mining, railways, municipal administration, data center, intelligent building and other industries.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\n1. System type can set as: S1 Mains S2Mains, S1 Mains S2 Gen, S1 Gen S2 Mains, S1 Gen S2 Gen;\u003cbr\u003e\n\u003cbr\u003e\n2. 4.3-inch single color 240x128 LCD display with white backlight, multilingual interface (Simplified Chinese, English, other), push-button operation;\u003cbr\u003e\n\u003cbr\u003e\n3. Collect and display 2-way 3-phase voltage, frequency and phase;\u003cbr\u003e\n\u003cbr\u003e\n4. Collect and display load active power, reactive power, apparent power, power factor and 2-way current;\u003cbr\u003e\n\u003cbr\u003e\n5. Display main breaker position status (work position, test position, isolation position), bypass breaker position status (work position, test position, isolation position);\u003cbr\u003e\n\u003cbr\u003e\n6. PT break detection function, whether PT wire is broken can be judged by measured voltage and current data and PT break status can be obtained by digital input ports;\u003cbr\u003e\n\u003cbr\u003e\n7. Load stepwise switch function, can realize current unit and external stepwise switch control. With current unit stepwise switch control, stepwise switch control of 24 load breakers can be realized, the priority of each load breaker can be flexibly set, close feedback status, work position status, test position status and trip status of each load breaker can be detected;\u003cbr\u003e\n\u003cbr\u003e\n8. Six 16-way digital input modules and three 16-way digital output modules can be expanded via RS485 interface;\u003cbr\u003e\n\u003cbr\u003e\n9. Bustie control function, suitable for 4-incoming 2-bustie application scheme (realize by two HMAT880 modules);\u003cbr\u003e\n\u003cbr\u003e\n10. Earth fault protection function;\u003cbr\u003e\n\u003cbr\u003e\n11. S1\/S2 independent overcurrent warning or trip alarm function;\u003cbr\u003e\n\u003cbr\u003e\n12. Forced open, PT break, communication failure, earth fault alarm functions;\u003cbr\u003e\n\u003cbr\u003e\n13. NEL trip function;\u003cbr\u003e\n\u003cbr\u003e\n14. Display S1\/S2 accumulated active energy, reactive energy;\u003cbr\u003e\n\u003cbr\u003e\n15. Display S1\/S2 accumulated close times of main breaker and bypass breaker;\u003cbr\u003e\n\u003cbr\u003e\n16. Display current continuous supply time, last continuous supply time and S1\/S2 accumulated supply time;\u003cbr\u003e\n\u003cbr\u003e\n17. For energy storage breaker, it can close after PF (close is ready) signal is active;\u003cbr\u003e\n\u003cbr\u003e\n18. Over\/under voltage, over\/under frequency, overcurrent, loss of phase, reverse phase sequence function;\u003cbr\u003e\n\u003cbr\u003e\n19. Auto\/manual transfer, manually control breaker close\/open in manual mode;\u003cbr\u003e\n\u003cbr\u003e\n20. All parameters can be configured on site. Passwords authentication ensures authorized staff operation only;\u003cbr\u003e\n\u003cbr\u003e\n21. Manual commissioning to achieve genset start\/stop operation;\u003cbr\u003e\n\u003cbr\u003e\n22. Breaker re-closing function of main\/bypass breaker in auto mode;\u003cbr\u003e\n\u003cbr\u003e\n23. Suit for single bypass, dual bypass and mutual backup dual bypass breakers;\u003cbr\u003e\n\u003cbr\u003e\n24. Suit for manual\/remote control bypass breaker;\u003cbr\u003e\n\u003cbr\u003e\n25. 2-way N-wire isolated design;\u003cbr\u003e\n\u003cbr\u003e\n26. Real-time clock (RTC); event log function (event log can record 200 items circularly);\u003cbr\u003e\n\u003cbr\u003e\n27. With black box function, can record 5 events circularly, 60 detailed data of 50s before each event record, and 10s after each event record;\u003cbr\u003e\n\u003cbr\u003e\n28. Scheduled routing run \u0026amp; scheduled not run (can be set as genset start once\/weekly\/monthly whether with load or not);\u003cbr\u003e\n\u003cbr\u003e\n29. Can control two gensets to work as cycle run mode, master-slave run mode and balanced time run mode;\u003cbr\u003e\n\u003cbr\u003e\n30. Wide DC power supply range allows the controller can bear instantaneous DC 80V input;\u003cbr\u003e\n\u003cbr\u003e\n31. Large AC wire terminal space, maximum AC 625V voltage input can be accepted;\u003cbr\u003e\n\u003cbr\u003e\n32. With Dual-RS485 isolated communication interface. With \"four remote\" (remote control, remote measurement, remote communication, remote adjusting) function by the ModBus-RTU communication protocol. Genset start\/stop and breaker close\/open can be controlled remotely;\u003cbr\u003e\n\u003cbr\u003e\n33. Suitable for various AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire methods);\u003cbr\u003e\n\u003cbr\u003e\n34. Modular design, anti-flaming ABS plastic shell, pluggable terminal, embedded mounting, compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":43976386412715,"sku":"HMAT880","price":2860.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/files\/31da5050-c562-506f-8080-37573cd7d2eb.png?v=1715152749"},{"product_id":"smartgen-hmat821s-ats-controller","title":"SmartGen HMAT821S ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(240*128)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 12\u003cbr\u003e\nProgrammable Output 13\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nOver Current Warn ●\u003cbr\u003e\nCurrent and Power Display ●\u003cbr\u003e\nMonitor Interface USB\/RS485-1\/RS485-2\u003cbr\u003e\nProgrammable Interface USB\/RS485-1\/RS485-2\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSync. Closing ●\u003cbr\u003e\nDC Supply DC12V\/24V\/48V\u003cbr\u003e\nCase Dimensions(mm) 260*180*54\u003cbr\u003e\nPanel Cutout(mm) 242*161\u003cbr\u003e\nOperating Temp. (-25~+70)˚C\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\n\u003cbr\u003e\nHMAT821 Series Medium Voltage Bus Tie ATS Controller is a module that integrates configurable function, automatic measurement, PT break detection, LCD display and digital communication. It combines digitization, intelligence and networking, the automatic measurement and control process can reduce incorrect operation, which is an ideal option for medium voltage bus-tie transfer.\u003cbr\u003e\n\u003cbr\u003e\nHMAT821 Series Medium Voltage Bus Tie ATS Controller is composed of microprocessor as the core, which can precisely detect 2-way 3-phase incoming voltage, make accurate judgment for voltage abnormal situations (over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence) and output passive control coil. With compact structure, advanced circuits, simple wiring and high reliability, it can be widely used in electrical automatic control system of electric power, telecom, petrochemical industry, mining, railways, municipal administration, data center, intelligent building and other industries.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\n1. System type can be set as: Mains - Mains, Mains - Gen, Gen - Mains;\u003cbr\u003e\n\u003cbr\u003e\n2. 4.3-inch single color 240x128 LCD display with white backlight, multilingual display (including Simplified Chinese, English and others), push-button operation;\u003cbr\u003e\n\u003cbr\u003e\n3. Collect and display 2-way 3-phase voltage, current, phase sequence, frequency and voltage imbalance;\u003cbr\u003e\n\u003cbr\u003e\n4. Display 2-way active power, reactive power, apparent power, power factor and earth current;\u003cbr\u003e\n\u003cbr\u003e\n5. PT break detection function, whether PT wire is broken can be judged by measured voltage and current data, or PT break status can be obtained by digital input ports;\u003cbr\u003e\n\u003cbr\u003e\n6. Display S1\/S2 total power supply time;\u003cbr\u003e\n\u003cbr\u003e\n7. Current duration and total duration of power supply for Load 1\u0026amp; Load 2;\u003cbr\u003e\n\u003cbr\u003e\n8. Display total close times of QS1, QS2 and QTIE;\u003cbr\u003e\n\u003cbr\u003e\n9. Detection functions of over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence;\u003cbr\u003e\n\u003cbr\u003e\n10. Earth fault protection function;\u003cbr\u003e\n\u003cbr\u003e\n11. S1\/S2 overcurrent warning or trip individual alarm function;\u003cbr\u003e\n\u003cbr\u003e\n12. NEL trip function;\u003cbr\u003e\n\u003cbr\u003e\n13. Manual commissioning to achieve genset start\/stop operation;\u003cbr\u003e\n\u003cbr\u003e\n14. Scheduled routing run \u0026amp; scheduled not run (can be set as genset start daily\/weekly\/monthly whether with load or not);\u003cbr\u003e\n\u003cbr\u003e\n15. Real-time clock (RTC);\u003cbr\u003e\n\u003cbr\u003e\n16. Event log function (event log can record 200 items circularly);\u003cbr\u003e\n\u003cbr\u003e\n17. With black box function, can record 5 events circularly, 60 detailed data of 50s before each event record, and 10s after each event record;\u003cbr\u003e\n\u003cbr\u003e\n18. Suitable for various AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire methods);\u003cbr\u003e\n\u003cbr\u003e\n19. Simultaneously control the closing and opening of the 2-way CB switch and the bus-tie CB switch to simplify the control system;\u003cbr\u003e\n\u003cbr\u003e\n20. For stored-energy type ATS, its can close after the PF input is active;\u003cbr\u003e\n\u003cbr\u003e\n21. Auto\/Manual transfer, manually control the switch close or open in manual mode;\u003cbr\u003e\n\u003cbr\u003e\n22. Local mode. When it is active, controller only displays data parameters, switch transfer needs to be realized by external operation;\u003cbr\u003e\n\u003cbr\u003e\n23. Electric interlock release function, which is used for releasing electric interlock in switch parallel transfer (only suits for HMAT821S);\u003cbr\u003e\n\u003cbr\u003e\n24. 6 kinds of buttons on the panel to manually control switch easily;\u003cbr\u003e\n\u003cbr\u003e\n25. Breaker re-closing function;\u003cbr\u003e\n\u003cbr\u003e\n26. Closing output signal can be set as pulse or continuous output, which is suitable for CB breaker or CC contactor;\u003cbr\u003e\n\u003cbr\u003e\n27. All parameters can be set on site. Passwords authentication ensures authorized staff operation only;\u003cbr\u003e\n\u003cbr\u003e\n28. 2-way N-wire isolated design;\u003cbr\u003e\n\u003cbr\u003e\n29. Wide DC power supply range allows the controller can bear instantaneous 80V DC input;\u003cbr\u003e\n\u003cbr\u003e\n30. Large terminal space allows the controller can bear maximum 625V AC voltage input;\u003cbr\u003e\n\u003cbr\u003e\n31. With Dual-RS485 isolated communication interface. With \"remote control, remote communication, remote measurement, remote adjusting\" functions by the ModBus-RTU Communication protocol. Genset start\/stop and ATS close\/open can be controlled remotely;\u003cbr\u003e\n\u003cbr\u003e\n32. USB is convenient to debug parameters and upgrade program locally;\u003cbr\u003e\n\u003cbr\u003e\n33. Modular design, self extinguishing ABS shell, silicone panel, pluggable terminal, built-in mounting, compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":43976671396011,"sku":"HMAT821S","price":2728.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/files\/987ac742-657e-5242-9f16-432ff690ffe4.png?v=1715153545"},{"product_id":"smartgen-hmat821-medium-voltage-bus-tie-ats-controller","title":"SmartGen HMAT821 Medium Voltage Bus Tie ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(240*128)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 12\u003cbr\u003e\nProgrammable Output 13\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nOver Current Warn ●\u003cbr\u003e\nCurrent and Power Display ●\u003cbr\u003e\nMonitor Interface USB\/RS485-1\/RS485-2\u003cbr\u003e\nProgrammable Interface USB\/RS485-1\/RS485-2\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nDC Supply DC12V\/24V\/48V\u003cbr\u003e\nCase Dimensions(mm) 260*180*54\u003cbr\u003e\nPanel Cutout(mm) 242*161\u003cbr\u003e\nOperating Temp. (-25~+70)˚C\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\n\u003cbr\u003e\nHMAT821 Series Medium Voltage Bus Tie ATS Controller is a module that integrates configurable function, automatic measurement, PT break detection, LCD display and digital communication. It combines digitization, intelligence and networking, the automatic measurement and control process can reduce incorrect operation, which is an ideal option for medium voltage bus-tie transfer.\u003cbr\u003e\n\u003cbr\u003e\nHMAT821 Series Medium Voltage Bus Tie ATS Controller is composed of microprocessor as the core, which can precisely detect 2-way 3-phase incoming voltage, make accurate judgment for voltage abnormal situations (over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence) and output passive control coil. With compact structure, advanced circuits, simple wiring and high reliability, it can be widely used in electrical automatic control system of electric power, telecom, petrochemical industry, mining, railways, municipal administration, data center, intelligent building and other industries.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\n1. System type can be set as: Mains - Mains, Mains - Gen, Gen - Mains;\u003cbr\u003e\n2. 4.3-inch single color 240x128 LCD display with white backlight, multilingual display (including Simplified Chinese, English and others), push-button operation;\u003cbr\u003e\n3. Collect and display 2-way 3-phase voltage, current, phase sequence, frequency and voltage imbalance;\u003cbr\u003e\n4. Display 2-way active power, reactive power, apparent power, power factor and earth current;\u003cbr\u003e\n5. PT break detection function, whether PT wire is broken can be judged by measured voltage and current data, or PT break status can be obtained by digital input ports;\u003cbr\u003e\n6. Display S1\/S2 total power supply time;\u003cbr\u003e\n7. Current duration and total duration of power supply for Load 1\u0026amp; Load 2;\u003cbr\u003e\n8. Display total close times of QS1, QS2 and QTIE;\u003cbr\u003e\n9. Detection functions of over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence;\u003cbr\u003e\n10. Earth fault protection function;\u003cbr\u003e\n11. S1\/S2 overcurrent warning or trip individual alarm function;\u003cbr\u003e\n12. NEL trip function;\u003cbr\u003e\n13. Manual commissioning to achieve genset start\/stop operation;\u003cbr\u003e\n14. Scheduled routing run \u0026amp; scheduled not run (can be set as genset start daily\/weekly\/monthly whether with load or not);\u003cbr\u003e\n15. Real-time clock (RTC);\u003cbr\u003e\n16. Event log function (event log can record 200 items circularly);\u003cbr\u003e\n17. With black box function, can record 5 events circularly, 60 detailed data of 50s before each event record, and 10s after each event record;\u003cbr\u003e\n18. Suitable for various AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire methods);\u003cbr\u003e\n19. Simultaneously control the closing and opening of the 2-way CB switch and the bus-tie CB switch to simplify the control system;\u003cbr\u003e\n20. For stored-energy type ATS, its can close after the PF input is active;\u003cbr\u003e\n21. Auto\/Manual transfer, manually control the switch close or open in manual mode;\u003cbr\u003e\n22. Local mode. When it is active, controller only displays data parameters, switch transfer needs to be realized by external operation;\u003cbr\u003e\n23. Electric interlock release function, which is used for releasing electric interlock in switch parallel transfer (only suits for HMAT821S);\u003cbr\u003e\n24. 6 kinds of buttons on the panel to manually control switch easily;\u003cbr\u003e\n25. Breaker re-closing function;\u003cbr\u003e\n26. Closing output signal can be set as pulse or continuous output, which is suitable for CB breaker or CC contactor;\u003cbr\u003e\n27. All parameters can be set on site. Passwords authentication ensures authorized staff operation only;\u003cbr\u003e\n28. 2-way N-wire isolated design;\u003cbr\u003e\n29. Wide DC power supply range allows the controller can bear instantaneous 80V DC input;\u003cbr\u003e\n30. Large terminal space allows the controller can bear maximum 625V AC voltage input;\u003cbr\u003e\n31. With Dual-RS485 isolated communication interface. With \"remote control, remote communication, remote measurement, remote adjusting\" functions by the ModBus-RTU Communication protocol. Genset start\/stop and ATS close\/open can be controlled remotely;\u003cbr\u003e\n32. USB is convenient to debug parameters and upgrade program locally;\u003cbr\u003e\n33. Modular design, self extinguishing ABS shell, silicone panel, pluggable terminal, built-in mounting, compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":43979267014827,"sku":"HMAT821","price":2546.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/files\/88d45803-957d-5987-9f62-05ef22bf5616.png?v=1715159503"},{"product_id":"smartgen-hat835s-three-power-bus-tie-controller","title":"SmartGen HAT835S Three Power Bus Tie Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(240*128)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 12\u003cbr\u003e\nProgrammable Output 12\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nCurrent and Power Display ●\u003cbr\u003e\nVolt Freq Protection ●\u003cbr\u003e\nOver Current Warn ●\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSync Transfer ●\u003cbr\u003e\nDC Supply DC(8～35)V\u003cbr\u003e\nCase Dimensions(mm) 260*180*54\u003cbr\u003e\nPanel Cutout(mm) 242*161\u003cbr\u003e\nOperating Temp. (-25~+70)℃\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT835S Three Power Bus Tie Controller is intelligent tri-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digitization, intelligence and networking. Automatic measurement and control can reduce human error, which is an ideal option for three power transfer.\u003cbr\u003e\n\u003cbr\u003e\nThe powerful microprocessor contained within the unit allows for precision voltage (3-way 3-phase) measuring and make accurate judgment and the corresponding volt free digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence and other abnormal condition occurs. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\n1. System type can set as: 3 powers 2 bustie, 3 powers 1 bustie; specifically includes 2T-TS-2L、2T-TS-3L、2T-3I-3L、2T-TS-3G、2T-3I-2L、LT-TP-1NPL、LT-TS-1NPL、LT-TS-LP、LT-TS-LP-3G、LT-TP-LP、LT-TS-3I、LT-TS-3IG、RT-TP-3I、RT-TS-LP-1G、RT-TS-LP-1IG；\u003cbr\u003e\n\u003cbr\u003e\n2. 4.3 inchs single color 240x128 LCD display with white backlight, multilingual interface (including English, Simplified Chinese or Traditional Chinese), push-button operation;\u003cbr\u003e\n\u003cbr\u003e\n3. LCD can visually display current system topology, S1\/S2\/S3 voltage, frequency and other parameters;\u003cbr\u003e\n\u003cbr\u003e\n4. Collect and display 3-way 3-phase voltage, frequency and phase sequence;\u003cbr\u003e\n\u003cbr\u003e\n5. With over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence detection function;\u003cbr\u003e\n\u003cbr\u003e\n6. Single breaker operation and system parameters adjusting can be conducted via front panel key;\u003cbr\u003e\n\u003cbr\u003e\n7. Display QS1\/QS2\/QS3\/QTIE1\/QTIE2 accumulated close times;\u003cbr\u003e\n\u003cbr\u003e\n8. Display S1\/S2\/S3 accumulated supply time, current continuous power time, last continuous power time and accumulated power time of LOAD1\/LOAD2\/LOAD3;\u003cbr\u003e\n\u003cbr\u003e\n9. For Stored-Energy type switch, its close relay will be active after the PF Input is active;\u003cbr\u003e\n\u003cbr\u003e\n10. Auto\/Manual mode transfer. In manual mode, it can force the switch to close or open;\u003cbr\u003e\n\u003cbr\u003e\n11. All parameters can be set on site. Passwords authentication ensures authorized staff operation only;\u003cbr\u003e\n\u003cbr\u003e\n12. The unit can be manually tested on site to achieve start\/stop operation;\u003cbr\u003e\n\u003cbr\u003e\n13. Closing output signal can be set as pulse or continuous output;\u003cbr\u003e\n\u003cbr\u003e\n14. Applicable for 3 isolated neutral line;\u003cbr\u003e\n\u003cbr\u003e\n15. With elevator delay output function;\u003cbr\u003e\n\u003cbr\u003e\n16. Real-time clock (RTC); event log function (event log can record 200 items circularly);\u003cbr\u003e\n\u003cbr\u003e\n17. Scheduled run \u0026amp; scheduled not run (can be set as start genset once a day\/week\/month whether with load or not);\u003cbr\u003e\n\u003cbr\u003e\n18. Can control multiple gensets to work as cycle run mode, master run mode, balanced time run mode;\u003cbr\u003e\n\u003cbr\u003e\n19. User can monitor data communication protocol address;\u003cbr\u003e\n\u003cbr\u003e\n20. PLC function is fitted;\u003cbr\u003e\n\u003cbr\u003e\n21. DIN16A-2 and DOUT16B-2 module can be connected via RS485 port;\u003cbr\u003e\n\u003cbr\u003e\n22. With Dual-RS485 isolated communication port. With \"remote control, remote measurement, remote communication, remote adjustment\" function by the ModBus-RTU communication protocol. It can remotely start\/stop the genset and control breaker close or open;\u003cbr\u003e\n\u003cbr\u003e\n23. Widely DC power supply range allows the controller can bear instantaneous 80V DC input;\u003cbr\u003e\n\u003cbr\u003e\n24. Large terminal space allows the controller can bear maximum 625V AC voltage input;\u003cbr\u003e\n\u003cbr\u003e\n25. Suitable for various AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire);\u003cbr\u003e\n\u003cbr\u003e\n26.Modular design, anti-flaming ABS plastic shell, pluggable terminal, built-in mounting, compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":43979415257259,"sku":"HAT835S","price":3142.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/files\/92d9cf6a-83aa-5457-b1e3-1e64e78b0b8b.png?v=1715161044"},{"product_id":"smartgen-hat835-three-power-bus-tie-controller","title":"SmartGen HAT835 Three Power Bus Tie Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(240*128)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 12\u003cbr\u003e\nProgrammable Output 12\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nOver Current Warn ●\u003cbr\u003e\nCurrent and Power Display ●\u003cbr\u003e\nVolt Freq Protection ●\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface USB\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nDC Supply DC(8～35)V\u003cbr\u003e\nPanel Cutout(mm) 242*161\u003cbr\u003e\nOperating Temp. (-25~+70)℃\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT835 Three Power Bus Tie Controller is intelligent tri-supply module with configurable function, automatic measurement, LCD display, and digital communication. It combines digitization, intelligence and networking. Automatic measurement and control can reduce human error, which is an ideal option for three power transfer.\u003cbr\u003e\n\u003cbr\u003e\nThe powerful microprocessor contained within the unit allows for precision voltage (3-way 3-phase) measuring and make accurate judgment and the corresponding volt free digital output port will active when there is over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence and other abnormal condition occurs. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electrical automatic control system of electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, etc.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\n1. System type can set as: 3 powers 2 bustie, 3 powers 1 bustie; specifically includes 2T-TS-2L、2T-TS-3L、2T-3I-3L、2T-TS-3G、2T-3I-2L、LT-TP-1NPL、LT-TS-1NPL、LT-TS-LP、LT-TS-LP-3G、LT-TP-LP、LT-TS-3I、LT-TS-3IG、RT-TP-3I、RT-TS-LP-1G、RT-TS-LP-1IG；\u003cbr\u003e\n2. 4.3 inchs single color 240x128 LCD display with white backlight, multilingual interface (including English, Simplified Chinese or Traditional Chinese), push-button operation;\u003cbr\u003e\n3. LCD can visually display current system topology, S1\/S2\/S3 voltage, frequency and other parameters;\u003cbr\u003e\n4. Collect and display 3-way 3-phase voltage, frequency and phase sequence;\u003cbr\u003e\n5. With over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence detection function;\u003cbr\u003e\n6. Single breaker operation and system parameters adjusting can be conducted via front panel key;\u003cbr\u003e\n7. Display QS1\/QS2\/QS3\/QTIE1\/QTIE2 accumulated close times;\u003cbr\u003e\n8. Display S1\/S2\/S3 accumulated supply time, current continuous power time, last continuous power time and accumulated power time of LOAD1\/LOAD2\/LOAD3;\u003cbr\u003e\n9. For Stored-Energy type switch, its close relay will be active after the PF Input is active;\u003cbr\u003e\n10. Auto\/Manual mode transfer. In manual mode, it can force the switch to close or open;\u003cbr\u003e\n11. All parameters can be set on site. Passwords authentication ensures authorized staff operation only;\u003cbr\u003e\n12. The unit can be manually tested on site to achieve start\/stop operation;\u003cbr\u003e\n13. Closing output signal can be set as pulse or continuous output;\u003cbr\u003e\n14. Applicable for 3 isolated neutral line;\u003cbr\u003e\n15. With elevator delay output function;\u003cbr\u003e\n16. Real-time clock (RTC); event log function (event log can record 200 items circularly);\u003cbr\u003e\n17. Scheduled run \u0026amp; scheduled not run (can be set as start genset once a day\/week\/month whether with load or not);\u003cbr\u003e\n18. Can control multiple gensets to work as cycle run mode, master run mode, balanced time run mode;\u003cbr\u003e\n19. User can monitor data communication protocol address;\u003cbr\u003e\n20. PLC function is fitted;\u003cbr\u003e\n21. DIN16A-2 and DOUT16B-2 module can be connected via RS485 port;\u003cbr\u003e\n22. With Dual-RS485 isolated communication port. With \"remote control, remote measurement, remote communication, remote adjustment\" function by the ModBus-RTU communication protocol. It can remotely start\/stop the genset and control breaker close or open;\u003cbr\u003e\n23. Widely DC power supply range allows the controller can bear instantaneous 80V DC input;\u003cbr\u003e\n24. Large terminal space allows the controller can bear maximum 625V AC voltage input;\u003cbr\u003e\n25. Suitable for various AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire);\u003cbr\u003e\n26. Modular design, anti-flaming ABS plastic shell, pluggable terminal, built-in mounting, compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":43979479253163,"sku":"HAT835","price":2860.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/files\/489fa598-99f8-5cba-bf71-8093af2ccfc6.png?v=1715161885"},{"product_id":"smartgen-hat821si-dual-power-bus-tie-controller","title":"SmartGen HAT821SI Dual Power Bus Tie Controller","description":"\u003cp\u003eHAT821SI Dual Power Bus Tie Controller is a medium voltage ATS module that integrates configurable function, automatic measurement, PT break detection, load stepwise transfer, LCD display and digital communication. It combines digitization, intelligence and networking, the automatic measurement and control process can reduce incorrect operation, which is an ideal option for dual power bus-tie transfer.\u003cbr\u003e\n\u003cbr\u003e\nHAT821SI Dual Power Bus Tie Controller is composed of microprocessor as the core, which can precisely detect 2-way 3-phase incoming voltage, make accurate judgment for voltage abnormal situations (over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence) and output passive control coil. With compact structure, advanced circuits, simple wiring and high reliability, it can be widely used in electrical automatic control system of electric power, telecom, petrochemical industry, mining, railways, municipal administration, data center, intelligent building and other industries.\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\nSystem type can be set as: Mains - Mains, Mains - Gen, Gen - Mains;\u003cbr\u003e\n4.3-inch single color 240x128 LCD display with white backlight, multilingual display (including Simplified Chinese, English and others), push-button operation;\u003cbr\u003e\nCollect and display 2-way 3-phase voltage, current, phase sequence, frequency and voltage imbalance;\u003cbr\u003e\nDisplay 2-way active power, reactive power, apparent power, power factor and earth current;\u003cbr\u003e\nPT break detection function, whether PT wire is broken can be judged by measured voltage and current data, or PT break status can be obtained by digital input ports;\u003cbr\u003e\nLoad switch stepwise transfer can realize the control of local and external. Up to 12 load switches of each way can be realized by local stepwise transfer control. The priority of each load switches can be set flexibly and the closing feedback status, operating position status, test position status and switch tripping status can be detected;\u003cbr\u003e\nReal-time detection of the load rate for 2 power supplies, intelligent loading and unloading can be performed according to the settings;\u003cbr\u003e\n6 16-way digital input modules and 4 16-way digital output modules can be extended by RS485 interface;\u003cbr\u003e\nDisplay S1\/S2 total power supply time; display current duration and total duration of power supply for Load 1\u0026amp; Load 2;\u003cbr\u003e\nDisplay total close times of QS1, QS2 and QTIE;\u003cbr\u003e\nDetection functions of over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence;\u003cbr\u003e\nEarth fault protection function;\u003cbr\u003e\nS1\/S2 overcurrent warning or trip individual alarm function;\u003cbr\u003e\nNEL trip function;\u003cbr\u003e\nManual commissioning to achieve genset start\/stop operation;\u003cbr\u003e\nScheduled routing run \u0026amp; scheduled not run (can be set as genset start daily\/weekly\/monthly whether with load or not);\u003cbr\u003e\nReal-time clock (RTC);\u003cbr\u003e\nEvent log function (event log can record 200 items circularly);\u003cbr\u003e\nWith black box function, can record 5 events circularly, 60 detailed data of 50s before each event record, and 10s after each event record;\u003cbr\u003e\nSuitable for various AC systems (3-phase 4-wire, 3-phase 3-wire, single-phase 2-wire, and 2-phase 3-wire methods);\u003cbr\u003e\nSimultaneously control the closing and opening of the 2-way CB switch and the bus-tie CB switch to simplify the control system;\u003cbr\u003e\nFor stored-energy type ATS, its can close after the PF input is active;\u003cbr\u003e\nAuto\/Manual transfer, manually control the switch close or open in manual mode;\u003cbr\u003e\nLocal mode. When it is active, controller only displays data parameters, switch transfer needs to be realized by external operation;\u003cbr\u003e\nElectric interlock release function, which is used for releasing electric interlock in switch parallel transfer;\u003cbr\u003e\n6 kinds of buttons on the panel to manually control switch easily;\u003cbr\u003e\nBreaker re-closing function;\u003cbr\u003e\nClosing output signal can be set as pulse or continuous output, which is suitable for CB breaker or CC contactor;\u003cbr\u003e\nAll parameters can be set on site. Passwords authentication ensures authorized staff operation only;\u003cbr\u003e\n2-way N-wire isolated design;\u003cbr\u003e\nWide DC power supply range allows the controller can bear instantaneous 80V DC input;\u003cbr\u003e\nLarge terminal space allows the controller can bear maximum 625V AC voltage input;\u003cbr\u003e\nWith Dual-RS485 isolated communication interface. With \"remote control, remote communication, remote measurement, remote adjusting\" functions by the ModBus-RTU Communication protocol. Genset start\/stop and ATS close\/open can be controlled remotely;\u003cbr\u003e\nUSB is convenient to debug parameters and upgrade program locally;\u003cbr\u003e\nModular design, self extinguishing ABS shell, silicone panel, pluggable terminal, built-in mounting, compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":43979528110251,"sku":"HAT821SI","price":1635.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/files\/e21ab1a1-41ba-53b2-9f07-895fbbc2721b.png?v=1715162603"},{"product_id":"smartgen-hat660-dual-power-synchronous-ats-controller","title":"SmartGen HAT660 Dual Power Synchronous ATS Controller","description":"\u003cp\u003eTechnical Parameters:\u003cbr\u003e\nDisplay LCD(132x64)\u003cbr\u003e\nLanguage Chinese \u0026amp; English \u0026amp; Others\u003cbr\u003e\nProgrammable Input 7\u003cbr\u003e\nProgrammable Output 8\u003cbr\u003e\nAC System 1P2W\/2P3W\/3P3W\/3P4W\u003cbr\u003e\nAlternator Frequency 50\/60Hz\u003cbr\u003e\nMonitor Interface RS485\u003cbr\u003e\nProgrammable Interface RS485\/USB\u003cbr\u003e\nRTC(Real Time Clock) ●\u003cbr\u003e\nScheduled Start Genset ●\u003cbr\u003e\nCirculate Start Genset ●\u003cbr\u003e\nSync Transfer ●（HAT660S）\u003cbr\u003e\nDC Supply DC(8～35)V\u003cbr\u003e\nCase Dimensions(mm) 198*154*54\u003cbr\u003e\nPanel Cutout(mm) 186*141\u003cbr\u003e\nOperating Temp. (-25~+70)°C\u003cbr\u003e\n\u003cbr\u003e\nProduct Overview:\u003cbr\u003e\nHAT660 Series Dual Power Synchronous ATS Controller is an intelligent dual-supply synchronous transfer module integrating programmable function, automatic measurement, LCD display, and digital communication. It combines digitalization, intelligence and networking. Automatic measurement and control reduces incorrect operation. It is an ideal option for dual power transfer.\u003cbr\u003e\n\u003cbr\u003e\nHAT660 Series Dual Power Synchronous ATS Controller is made by microprocessor as its core, which can accurately detect 2-way-3-phase voltage, make accurate judgment and output passive control switch for occurred abnormal voltages (over\/under voltage, loss of phase, over\/under frequency). This controller is applicable for Mains-Mains, Mains-Gen, Gen-Gen power supply system and can be used for transfer switch of PC class, CB class, and CC class after full consideration on various ATS (Automatic Transfer System) applications; Meanwhile it realizes synchronous transfer of two power supplies. It has compact structure, advanced circuits, simple wiring and high reliability, and can be widely used in electric power, telecommunications, petroleum, coal, metallurgy, railways, municipal administration, intelligent building, electrical devices, automatic control and testing system etc.\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nPERFORMANCE AND CHARACTERISTICS\u003cbr\u003e\n\u003cbr\u003e\n1. LCD 132x64 pixel with backlight, multiple language display (Simplified Chinese, English, Other), push button operation;\u003cbr\u003e\n\u003cbr\u003e\n2. LED lamp can directly display current ATS close\/open status, power status and whether load is power on;\u003cbr\u003e\n\u003cbr\u003e\n3. System type can be set to: Mains (1#) \u0026amp; Mains (2#), Mains (1#) \u0026amp; Generator (2#), Generator (1#) \u0026amp; Mains (2#), Generator (1#) \u0026amp; Generator (2#);\u003cbr\u003e\n\u003cbr\u003e\n4. S1 master, or S2 master can be set; Auto Transfer Auto Restore and Auto Transfer Non Restore are fitted for master power supply;\u003cbr\u003e\n\u003cbr\u003e\n5. Collect and display 2-way 3 phase Voltage, Frequency, and Phase Sequence Status;\u003cbr\u003e\n\u003cbr\u003e\n6. Collect and display load active power, reactive power, apparent power, power factor and current;\u003cbr\u003e\n\u003cbr\u003e\n7. Isolated sampling is applied;\u003cbr\u003e\n\u003cbr\u003e\n8. Independent overcurrent warning or trip alarm functions for S1\/S2;\u003cbr\u003e\n\u003cbr\u003e\n9. NEL trip function is fitted;\u003cbr\u003e\n\u003cbr\u003e\n10. Display of S1\/S2 accumulated active power, accumulated reactive power, accumulated close times is fitted;\u003cbr\u003e\n\u003cbr\u003e\n11. Each phase voltage of S1\/S2, wave distortion rate of load current and 3-21 odd times harmonic percentage can be measured;\u003cbr\u003e\n\u003cbr\u003e\n12. Display of current power supply time and S1\/S2 continuous power supply time is available;\u003cbr\u003e\n\u003cbr\u003e\n13. Automatic and manual synchronous transfer function is applicable, and the difference of voltage, frequency and phase of two circuits can be displayed;\u003cbr\u003e\n\u003cbr\u003e\n14. For energy storage switch, users can wait for and close the switch until PF (close is ready) signal is active;\u003cbr\u003e\n\u003cbr\u003e\n15. Over\/under voltage, over\/under frequency, loss of phase, reverse phase sequence monitoring functions are fitted;\u003cbr\u003e\n\u003cbr\u003e\n16. Auto\/Manual transfer is fitted, so that breaker can be forced to close or open in manual mode;\u003cbr\u003e\n\u003cbr\u003e\n17. With local mode, the controller only displays data parameter when it is active and the switch needs to be transferred by external operations;\u003cbr\u003e\n\u003cbr\u003e\n18. Electrical interlock release function for switching in parallel (HAT660S only);\u003cbr\u003e\n\u003cbr\u003e\n19. All parameters can be configured on site; password is used to verify in case of non-professionals wrong operation;\u003cbr\u003e\n\u003cbr\u003e\n20. Custom start screen function is fitted;\u003cbr\u003e\n\u003cbr\u003e\n21. Commissioning can be done manually on site to conduct genset start\/stop operations;\u003cbr\u003e\n\u003cbr\u003e\n22. Switch re-close and breakout re-close functions are fitted;\u003cbr\u003e\n\u003cbr\u003e\n23. Close output can be set to pulse or continuous output;\u003cbr\u003e\n\u003cbr\u003e\n24. Applicable for switches of PC class two-stage, PC class three-stage, CB class and CC class;\u003cbr\u003e\n\u003cbr\u003e\n25. Real time clock display, and event log function, which can record 200 data circularly;\u003cbr\u003e\n\u003cbr\u003e\n26. Black box function, which can record 5 items of events of ATS transfer, and 60 detailed data of 50s before each event record, and 10s after each event record;\u003cbr\u003e\n\u003cbr\u003e\n27. Scheduled run\/not run function for genset, run for once, run monthly or weekly, and run on load or unload can also be set;\u003cbr\u003e\n\u003cbr\u003e\n28. Two gensets can be controlled and cycle run, master run, and balanced time run can be realized;\u003cbr\u003e\n\u003cbr\u003e\n29. Wide DC supply range, maximum 80V DC input for transient;\u003cbr\u003e\n\u003cbr\u003e\n30. Wide wire terminal space of AC input, maximum 528V voltage input;\u003cbr\u003e\n\u003cbr\u003e\n31. USB port, provides convenience for on-site debugging, and parameter or software upgrade;\u003cbr\u003e\n\u003cbr\u003e\n32. RS485 isolated communication port, making the controller has remote control, remote communication, remote measurement, remote adjustment functions by ModBus-RTU; it can remote control genset start\/stop, ATS close and open;\u003cbr\u003e\n\u003cbr\u003e\n33. ETHERNET port, making the controller has remote control, remote communication, remote measurement, remote adjustment functions by ModBus TCP\/IP; it can remote control genset start\/stop, ATS close and open;\u003cbr\u003e\n\u003cbr\u003e\n34. Suitable for multiple AC system types (3P4W, 3P3W,1P2W, 2P3W);\u003cbr\u003e\n\u003cbr\u003e\n35. Master and backup power supply can be set; ATS can normally work if one circuit is normal;\u003cbr\u003e\n\u003cbr\u003e\n36. Controller uses metal clips to fix;\u003cbr\u003e\n\u003cbr\u003e\n37. Modular design, flame retardant ABS plastic shell, pluggable terminal, built-in mounting, compact structure with easy installation.\u003c\/p\u003e\n","brand":"SMARTGEN","offers":[{"title":"Default Title","offer_id":43979626971307,"sku":"HAT660","price":306.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/files\/b32a39d4-9c1b-5e75-be78-9c430e573955.png?v=1715163839"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0251\/1660\/6498\/collections\/ab3a10ce-6e85-5845-a837-d1c1a88748bf_1.jpg?v=1668784976","url":"https:\/\/www.ats4pro.com\/collections\/ats-controllers\/atse-controller.oembed","provider":"AUTO POWER SWITCHING ","version":"1.0","type":"link"}